AIR FORCE A-A-58000-1992 TANK STORAGE LIQUID ARGON-NITROGEN-OXYGEN CRYOGENIC HORIZONTAL 3000 AND 6000 GALLON《3000和6000加仑水平低温氧氮液态氩贮藏罐》.pdf
《AIR FORCE A-A-58000-1992 TANK STORAGE LIQUID ARGON-NITROGEN-OXYGEN CRYOGENIC HORIZONTAL 3000 AND 6000 GALLON《3000和6000加仑水平低温氧氮液态氩贮藏罐》.pdf》由会员分享,可在线阅读,更多相关《AIR FORCE A-A-58000-1992 TANK STORAGE LIQUID ARGON-NITROGEN-OXYGEN CRYOGENIC HORIZONTAL 3000 AND 6000 GALLON《3000和6000加仑水平低温氧氮液态氩贮藏罐》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、e A-A-58000 36 W 9999974 0064430 9 m A-A-58000 16 MAR 1992 COMMERCIAL ITEM DESCRIPTION TANK, STORAGE8 LIQUID ARGON-NITROGEN-OXYGEN, Cryogenic, Hori- zontal, 3000 and li000 Gallon The aeneral Services Administration has authorized ttie use of this Commercial Ikem Description. 1. SCOPE 1.1 ScopeL This
2、 Commercial Item Description (CID),.describes a 3000 and 6000 gallon horizontal cryogenic storage tank capable of storing and delivering liquid oxygen or liquid nitrogen. 1.2 Classification. The storage tanks shall be of the following types and sizes. The type and size of storage tank to 0 be furnis
3、hed shall be as specified (see 6.1). Type I - Liquid Oxygen Type TI - Liquid Nitrogen Size A - 3000 Gallon Size B - 6000 Gallon Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data which may improve this document should be sent to: SA-ALC/SFRT Kelly AFB
4、 TX 78241-6000, by using ttie Standardization Document Improvement Proposal (DD Form 14261 appearing at the end of this document, or by letter. _._ DISTI$IBUTION -_ -_-_-I- STATWENT - A. Approved for public release; . distribution is unlimited, . FSC 3655 Provided by IHSNot for ResaleNo reproduction
5、 or networking permitted without license from IHS-,-,-A-A-58000 36 9999974 0064431 O 9 i A-A-5 8 O00 2 o APPLICABLE DOCUMENTS 2.1 doernment_locument_sL The following documents of the issue in effect on the date of invitation for bids or request for proposals form a part of this description to the ex
6、tent s ge c: i f i e d he re i n . Mi c i. tam MTIJ-i-27301 - Hose Assembly, Metal, Cryogenic Transfer iquid, MIL-STD-130 - Identification, Marking of U.S. Military Property PED-STD-376 - Preferred Metric Units For General Use By The Fedeye1 Government FED-STD-595 - Col06S Un ess otherwise indicated
7、, copies of federal and military specifications, standards, and handbooks are available from the Nuval Publications and Forms Center, ATTN: NPODS, 51301 Tabor Avenue, Philadelphia, PA 112O-5O9W. 8987831 8987840 8987856 8987857 8987870 8987877 8987878 8987889 8981891 8991172 8991174 Assembly, LOX Cou
8、pling, Female Half, All Sizes Hebairiing Ring, l-Inch Cone, l-Inch Nut, l-Inch Plug, l-inch Cone, l-Inch Nut, 1 Inch Assembly, Liquid Nitrogen Coupling, Female Half, All Sizes Plug, l-Inch Assembly, Liquid Nitrogen Coupling, Female Half, l-Inch Assembly, LOX Coupling, Female Half, l-Inch 2 Provided
9、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. A-A-5 8 O00 _ Air- Force 8221044-01 Decal, Liquid Oxygen 8221045-01 Decal, Liquid Nitrogen 8321391 Filter Assembly, 1-Inch 8518507 Filter, Assembly, 2-Inch 8752448-01 Nameplate (Copies of Drawings required by
10、suppliers in connection with specific acquisition functions shall be obtained from the contracting activity, or as directed by the contracting officer. 1 (Unless otherwise indicated, copies of the Federal Acquisition Regulation (FAR) are available by contacting, Superintendent of Documents, Congress
11、ional Sales Office, U.S. Government Printing Ofice, Washjrigtori, DC 20.102 1 L. 2 Other.Pi!kl c-at-_ionsc. The following document forms a part of t.Iiis specification to the extent; specified herein. Unless otherwise indicated, the issue in effect on the date of invitation for. bids or request for
12、proposal shall apply. . Ame?- icnn Sc_ci e.tx of. Mec!a!.cal-Engineers ASME Boiler and Fressure Vessel Code, Section VITI, Div 1 (Copies may Le purchased from American Society of Mechanical Engineers, 1Jni.ted Engineering Center, 345 East 47th Street, New York, NY 1001 7 ) G-4.1 Cleaning Equipment,
13、Por Oxygen Service V-6 S taridard Cryogenic Liquid Transfer Connections (Jnless otherwise indicated, copies shall be obtained from, Coniprecsed Gais AssocitI,ion Znc., 1235 Jefferson Davis Highway, Ar1 i rigton VA 22202 ) 2.3 Order oi-Pr.ecedence.r In the event of a conflict between Lhe text, of thi
14、s CID and the references cited herein, the text of this CID shall talie precedence. Nothing in this CID, however, shall supersede applicable laws and regulations unless tl specific exemption has been obtained. 3. SALIENT CHARACTERISTICS 3.1 DesignL The storage tanks shall be new and of the mariufact
15、urers commercial design in effect on the date of the solicitation. The storage tanks shall meet the requirements specified herejn and shall conforin to current commercial industrial practj ce. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-580
16、00 36 W 9999974 0064433 4 A-A- 5 8 O O O 3.2 CapacitL The storage tanks shall have a net volume of 3000 gal.lons (t 1 or (-) 2 percent or 6000 gallons (t 1 or (-) 2 percent (see 6.1). The tank shall have a gross water volume rating of not less than 102 percent of the rated net volume. ,- 3.3 Djmeng.
17、ionsI. The envelope dimensions of the tank shall not exceed 9 feet, iii width and 10 feet in height. The length for the 3000 arid 6000 (see 6.1) gallon tank, including the plumbing, shall not exceed 20 feet and 32 feet, respectively. 3.4 Gapabiljties, The Lank shall be capable of storing and deliver
18、ing liquid oxygen or liquid nitrogen (see 6.1). The tank shall be designed and fabricated per ASME, Boiler and Pressure Vessel Code, Section VILI, Div 1 for a maximum allowable working pressure of not less than 55 psig. The tank shall incorporate ari integral pressure building unit with adequate hea
19、t absorption cliaracteristics for the respective size tank. 3.5 P-Iug!bing Requ-irementsL The tank shall have plumbing lines and associated valves to include, as a minimum, top and bottom fill, liquid withdrawal, vent, full trycock, pressure building unit and instrumentation. 3.5.1 Top-and Bottom Fi
20、ll Line.% The top and bottom fill line shal I iiicorporate a 2-inch filter, per AF Drawing 8518507, iipstrearn of the fill line valve. The filter shall be incorporated into the plumbing system to facilitate removal and replacement. The top and bottom fill line shall terminate ir a SLandard Connectio
21、n, OX-150 or NI-150 (see 6.1), IAW CGA Paniphlet V-8, Standard Cryogenic Liquid Transfer Connections. A ill line safety valve, a fill line drain valve and a fill line check valve shall also be required. 3. 5. 2 Li_qui.cawllhd_r.awu.l_Lhn-. The liquid withdrawal line shall incovporate H l-inch filter
22、, per AF Drawing 8321391, downstream of the 1iqiii.d withdrawal line valve. This filter shall also be j ricoryorated into the plumbing system to facilitate removal and replacement. The liquid withdrawal line shall terminate in a 1-inch inale NPT nipp1.e to facilitate the attachment of the hose speci
23、fied in 3.8. A withdrawal line safety valve and a withdrawal line drain valve shall also be required. 3. 6 P.rolect;on_lle.ces, Pressure relief devices shal.1 be provided for protection of the inner tank arid the outer shell. The inner tank shall have, as minimum, a primary and secondary rel.ief dev
24、ice sized and set per ASME Code, section VIII, Division 1 to allow for- a normal operating pressure of 50 psig. 3.7 nstritentatt,onL All instruments and isolation valves necessary for effective and safe operation of the tank shall be provided. Specific marking requirements for the pressure gage arid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA580001992TANKSTORAGELIQUIDARGONNITROGENOXYGENCRYOGENICHORIZONTAL3000AND6000GALLON3000 6000

链接地址:http://www.mydoc123.com/p-426894.html