《AIIM MS39-1987 Recommended Practice for Operational Procedures Quality Control and Inspection of Graphic Computer-Output Microforms《质量控制和检验计算机输出缩微的推荐实施规程》.pdf》由会员分享,可在线阅读,更多相关《AIIM MS39-1987 Recommended Practice for Operational Procedures Quality Control and Inspection of Graphic Computer-Output Microforms《质量控制和检验计算机输出缩微的推荐实施规程》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、1900 Wayne Avenue, Suite I i00 Silver Spring, Maryland 2091 O Telephone 301 /587-8202 Approved As September 25, 1987 AIIM MS39 A7 W LOL234 0000334 7 W ANSIIAIIM MS39-1987 Standard for Information and Image Management - Recommended Practice for Operational Procedures, Quality Control and Inspection o
2、f Graphic Computer- Output Microforms _- Association for Information and Image Management This document describes operationai and quality control guidelines for graphic computer-output microfilm (COM) recorders and microforms using black and white film as well as duplicates made from such films. It
3、covers graphic COM recorders which have the capability of producing both alphanumeric images and graphic images such as those used for the output of engineering drawings and cartography. AIIM MS3 87 = i012348 0000335 9 nble of Contents Foreword .i 1. Scope . 1 2. References . 1 2.1 American Nafional
4、 Standards 1 2.2 Related Standards 1 3. Definitions. 1 4. Microfilm Qpes . .2 4.1 Silver-gelatin Film .2 4.2 Thermaliy Processed Silver Film. . .2 4.3 Dim Film. . .2 4.4 Vesicular Film 3 5. Film Processing. . .3 5.1 Silver-gelatin Film Processors. .3 5.2 Process Control . 3 5.3 Silver-gelatin Film P
5、rocessing. .5 5.4 Conventional Film Processing. .5 5.5 Reversal Processing . .5 6. Permanence of Microforms . 5 6.1 Archival Microforms: Records for Permanent 6.2 Long-term Microforms. .6 6.3 Medium-term Microforms .6 6.4 Diazo Duplicating Films . .6 6.5 Thermally Processed Silver Microforms . 6 6.6
6、 Vesicular Microfilm . .6 7. Graphic COM Quality Test Frames. . ,6 7.1 Using the Test Frames . .6 7.2 Reference Sample . -6 7.3 Routine Testing. .6 7.4 Tests for Frame Size, Linearity, Rectangularity, Orthogonality, Line Straightness and Uniformity of Line Width 7 7.5 Resolution Test . .9 7.6 Radial
7、 Recording Check 10 7.7 Test Frame for Measuring COM Recorder Intensity and Focus on a Daily Basis 10 8. Microfilm Density 11 8.1 General 11 8.2 Density of First-generation Film (COM Camera Film)., . i2 9. Density of Distribution Copies. .14 9.1 Negative-appearing (2N) Vesicular Film. 14 9.2 Negativ
8、e-appearing (2N, 3N, etc.) Diazo Film14 9.3 Positive-appearing (2P, 3P, etc.) Film . 14 10. Resolution. .14 10.1 General. . .14 10.2 Requirements . ,14 ll. Reproducibility . .14 12. Printability Test .14 13. Storing Microfilm . 14 Storage., . .5 Appendix A, Test Frame for Measuring Image Centering a
9、nd Camera Rotation 16 Appendix B, Test Frame for Measuring Image Frame Size 17 Appendix C, Test Frame for Measuring Spot Size and Intensity ,18 Appendix D, Test Frame for Measuring Camera Settling . 18 Appendix E, Test Frame for Measuring Character Appendix F, Test Frame for Displaying the Character
10、 Appendix G, Test Frame for Measuring Circle Appendix H, Test Frame for Measuring Character sizes . .E9 Set . 20 Quali ty, 21 Display and Rotation . .22 FIGURES Figure 1, COM generation terminology .2 4 Figure 3, Formula for determining standard deviation . 4 Figure 4, Linearity, rectangularity, ort
11、hogonality, line straightness, and uniformity of line width. .7 Figure 5, Resolution test . 9 Figure 6, Radial pairs of vectors 10 Figure 7, Intensity and focus check 11 Figure B1, Test frame for measuring image frame Figure C1, Test frame for measuring spot size and Figure D1, Test frame for measur
12、ing camera Figure El, Test frame for measuring character Figure Fl, Test frame for displaying character Figure G1, Test frame for measuring circle Figure H1, Test frame for measuring character Figure 2, Film processor control log Figure Al, Image centering test frame . i6 size 17 intensity 18 settli
13、ng . 19 sizes . 20 set . 20 quality. .21 display and rotation. . .22 TABLES Bble 1, Summary of acceptable density levels . 13 Table 2, Resolution values at three quality levels . 15 Foreword (This foreword is not part of the American National Stan- dard for Information and Image Management - Recom-
14、mended Practice for Operational Procedures, Quality Con- trol and Inspection of Graphic Computer-Output Micro- This document is a companion to ANSUAIIM MS1-1988. Whereas ANSI/AIIM MS1-1988 covers alpha- numeric COM quality, this document describes stan- dards for graphic COM quality. Graphic COM equ
15、ipment is used in scientific, engineering, architectural and car- tographic applications. Evaluating graphic COM image quality is a complex task, because there are a large number of out-of- specification conditions which can occur in a graphic COM recorder that are not possible or not visible in eit
16、her a source document system or an alphanumeric COM recorder, Whereas evaluation of an alphanumeric COM recorder can be accomplished using a form slide as the reference, evaluation of a graphic COM recorder is more forms, ANSVAIIM MS39-1987). i AIIM MS3 87 LOI12348 0000336 O difficult. The precision
17、 of recording in graphic COM is generally much higher than that obtained with alpha- numeric COM and many graphic COM recorders have no provision for a form slide. In these cases, it is necessary that all measurements be made on inages recorded from the dynamic image generator, usually a cathode ray
18、 tube. If the recorder is equipped for the use of form slides, then the form slide can be recorded. If measurements of this image meet the requirements, then the form slide may be used as a reference. Suggestions for improvement of this standard are welcome and should be sent to the Chairman, AUM St
19、an- dards Board, Association for Information and Image Management, il00 Wayne Avenue, Silver Spring, Maryland 20910. At the time this standard was approved, the AIIM Standards Board had the following members: Marilyn Courtot, Chairman Thomas C. Bagg Thomas E. Berney Joseph Comiskey William E. Neale
20、Henry C. Frey Delmar Johnson The COM Quality and Control Standards Commit- tee, C4, had the following members at the time it drafted and approved the standard: Paul R. Law Alan S. Linden Marcus H. Phillips Organization DatagraphiX Inc. Bell and Howell Computer Microfilm International Corp. Dicomed C
21、orporation Eastman Kodak Company IBM Corporation Information International National Bureau of NCR Micrographics Northern Micrographics Ozalid Corporation Photographic Sciences, 3M Company Westinghouse Electric Xidex Corporation Inc. Standards Systems Inc. Inc. corp. Representative Sherman Boyd, Chai
22、rman John Scarbrough Crawford Reed John Grimaldi I. Frank Rosati Joseph Comiskey Richard Gershbock Thomas Bagg Siegfried Mohr C. Daniel Gelatt David Jefferson Donna Keller Al Rouhan Gerald Clarke John Weaver AIIM MS39 87 I LO12348 0000337 2 = American National Standard for Infor- mation and Image Ma
23、nagement- Recommended Practice for Operational Procedures, Qualify Control and In- spection of Graphic Computer-Output Microforms, ANSI/AIIM MS39-1987 1. scope This document describes operational and quality con- trol guidelines for graphic computer-output microfilm (COM) recorders and microforms us
24、ing black and white film as well as duplicates made from such films. It covers graphic COM recorders which have the capability of pro- ducing both alphanumeric images and graphic images such as those used for the output of engineering drawings and cartography. This recommended practice covers microf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIIMMS391987RECOMMENDEDPRACTICEFOROPERATIONALPROCEDURESQUALITYCONTROLANDINSPECTIONOFGRAPHICCOMPUTEROUTPUTMICROFORMS

链接地址:http://www.mydoc123.com/p-426776.html