AHRI 520-2004 PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS.pdf
《AHRI 520-2004 PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS.pdf》由会员分享,可在线阅读,更多相关《AHRI 520-2004 PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/AHRI Standard 520 (formerly ARI Standard 520) 2004 Standard for PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS Price $10.00 (M) $20.00 (NM) Copyright 2004, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Offi
2、ce IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed,
3、constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry prac
4、tices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 520-97. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope .1 Section 3. Definitions .1 Section 4.
5、Test Requirements .2 Section 5. Rating Requirements .2 Section 6. Minimum Data Requirements for Published Ratings 3 Section 7. Operating Requirements 3 Section 8. Marking and Nameplate Data 3 Section 9. Conformance Conditions .3 TABLES Table 1. ARI Standard Rating Conditions for Condensing Units for
6、 Refrigeration Applications .4 APPENDICES Appendix A. References Normative 5 Appendix B. References Informative 5 Appendix C. Method to Handle Zeotropic Mixtures Informative .6 FIGURES Figure C1. Cycle Process for Single Component Refrigerants and Azeotropic Mixtures .6 Figure C2. Cycle Process for
7、Zeotropic Refrigerant Mixtures 7 Figure C3. Definitions of Subcooling and Superheating .8 ANSI/AHRI STANDARD 520-2004 1 PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for positive displacement condensing unit
8、s: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, designers, instal
9、lers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to electric motor driven, single and variable capacity positive displacement condensing units for air-cooled, evaporativ
10、ely-cooled, and water-cooled refrigeration applications. 2.1.1 Refrigerant. The rating points in this standard are based on commonly used refrigerants. 2.2 Exclusions. 2.2.1 This standard does not apply to condensing units intended for use in: a. Household refrigerators and freezers b. Automotive ai
11、r-conditioners c. Dehumidifiers Section 3. Definitions All terms in this document follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Coefficient of Performance
12、 (COP). A ratio of the Cooling/Heating Capacity in watts W to the power input values in watts W at any given set of Rating Conditions expressed in watts/watt W/W. For heating COP, supplementary resistance heat shall be excluded. 3.1.1 Standard Coefficient of Performance. A ratio of the capacity to p
13、ower input value obtained at Standard Rating Conditions. 3.2 Energy Efficiency Ratio, (EER). A ratio of the Cooling Capacity in Btu/h to the power input values in watts at any given set of Rating Conditions expressed in Btu/(Wh). 3.2.1 Standard Energy Efficiency Ratio. A ratio of the capacity to pow
14、er input value obtained at Standard Rating Conditions. 3.3 Positive Displacement Condensing Unit. A specific combination of refrigeration system components for a given refrigerant, consisting of one or more electric motor driven positive displacement compressors, condensers, and accessories as provi
15、ded by the manufacturer. ANSI/AHRI STANDARD 520-2004 2 3.4 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (i
16、dentification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.4.1 Application Rating.
17、A rating based on tests performed at application Rating Conditions, (other than Standard Rating Conditions). 3.4.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.5 Rating Conditions. Any set of operating conditions under which a single level of performance result
18、s and which causes only that level of performance to occur. 3.5.1 Standard Ratings Conditions. Rating conditions used as the basis of comparison for performance characteristics. 3.6 Refrigerating Capacity. The capacity associated with the increase in total enthalpy between the liquid refrigerant ent
19、ering the expansion valve and superheated return gas multiplied by the mass flow rate of the refrigerant. 3.7 “Shall“ or “Should“. “Shall” or “should” shall be interpreted as follows: 3.7.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that provision is mandatory if complian
20、ce with the standard is claimed. Should. “Should,“ is used to indicate provisions which are not mandatory, but which are desirable as good practice. Section 4. Test Requirements 4.1 Test Requirements. All Published Ratings shall be verified by tests conducted in accordance with ASHRAE Standard 23. S
21、ection 5. Rating Requirements 5.1 Standard Ratings. Standard Ratings shall be established at the Standard Rating Conditions in Table 1 and shall include its associated power input and Energy Efficiency Ratio (EER). When tested with a specified motor, the associated compressor speed (external drive c
22、ompressors only) shall also be included as part of the rating. The power required to operate all included accessories such as condenser fans, water pumps, controls, and similar accessories shall be accounted for in the power input and Energy Efficiency Ratio. When external accessories such as water
23、pumps, remote fans, and similar accessories are required for the operation of the unit but not included with the unit, the manufacturer shall clearly state that the rated power input and Energy Efficiency Ratio do not account for additional power required by these external accessories. If a water-co
24、oled condenser is used, the cooling water flow rate and pressure drop shall be specified as part of the rating. 5.2 Application Ratings. Application Ratings shall consist of a Capacity Rating plus the associated power input and Energy Efficiency Ratio (EER). When tested with a specified motor, the a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI5202004PERFORMANCERATINGOFPOSITIVEDISPLACEMENTCONDENSINGUNITSPDF

链接地址:http://www.mydoc123.com/p-422543.html