AECMA PREN 2346-003-2001 Aerospace Series Cable Electrical Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 003 DL Family Single Core Product Stan.pdf
《AECMA PREN 2346-003-2001 Aerospace Series Cable Electrical Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 003 DL Family Single Core Product Stan.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 2346-003-2001 Aerospace Series Cable Electrical Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 003 DL Family Single Core Product Stan.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication 2001-11-30 prEN 2346-003 Edition P 1 November 2001 Comments should be sent within six months after the date of publication to AECMA-STAN Mr Peuetta Gulledelle 94 Electrical Domain 8-1200 BRUXELLES PUBLISHED BY THE EUROPEAN ASSOCI
2、ATION OF AEROSPACE INDUSTRIES - STANDARDIZATION (AECMA-STAN) Gulledelle 94 - 8-1200 BRUXELLES - Tel. (+32) 2 775 81 10 - Fax. (+32) 2 775 81 11 ICs: 49.060 Descriptors: ENGLISH VERSION Aerospace series Cable, electrical, fire resistant Operating temperatures between - 65 OC and 260 OC Part 003: DL f
3、amily, single core Prod u ct standard Srie arospatiale Cbles lectriques rsistant au feu Tempratures de fonctionnement comprises entre - 65 “C et 260 “C Partie 003 : Famille DL, fil simple Norme de produit Luft- und Raumfahrt Feuerbestndige elektrische Leitungen Betriebstemperaturen zwischen - 65 “C
4、und 260 “C Teil 003: DL-Familie, eine Leitung Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published on green paper for the needs of the European Aerospace Industry
5、. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification o
6、f the standard. After examinafion and review by users and formal agreement of AECMA-STAN it will be submitted as a draft European Standard to CEN (European Committee for Standardization) for formal vote. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under
7、license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 2 prEN 2346-003: 2001 Contents 1 2 3 4 4.1 4.2 4.3 4.4 5 6 7 a 9 10 11 Normative references . Definitions . Materials and construction . . . Number of cores . Colour coding of cores Required cha
8、racteristics . . Quality assurance . Designation . Identification, markin . Packaging, labelling and delivery lengths . Technical specification Page 3 3 3 3 3 4 4 4 4 4 7 7 7 7 7 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for
9、 ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 prEN 2346-003: 2001 I Scope This standard specifies the characteristics of fire resistant electrical cables for use in the on-board electrical systems of aircraft at operating temperatures between - 65 “C and 260 “C.
10、2 Normative references This European Standard incorporates by dated or undated reference provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisio
11、ns of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. IEC 28: 1925 EN 2234 EN 2346-002 EN 3042 EN 3475 * EN 3475-100 International standard of resistance
12、 for copper Aerospace series - Cable, electrical, fire resistant - Technical specification 1) Aerospace series - Cable, electrical, fire resistant - Operating temperatures between - 65 “C and 260 “C - Pari 002: General 1) Aerospace series - Quality assurance - EN aerospace products - Qualification p
13、rocedure Aerospace series - Cables, electrical, aircraft use - Test methods Aerospace series - Cables, electrical, aircraft use -Test methods - Pari 100: General 1) 3 Definitions For the purposes of this standard, the definitions given in EN 3475-100 apply. 4 Materials and construction 4. I Material
14、s Conductors: Individual strands used for the conductors shall be cylindrical and shall be: - of nickel clad copper alloy for nominal cross sections of 0,4 mm2 (004); - of nickel clad copper for nominal cross sections 2 0,6 mm2 (006). The copper shall meet the requirements of IEC 28 and the copper a
15、lloy the requirements of EN 2234. Insulation: The insulation shall comply with the requirements of EN 2234. * And all its parts quoted in this standard 1) Published at AECMA Prestandard at the date of publication of this standard Copyright Association Europeene des Constructeurs de Materiel Aerospat
16、ial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 4 prEN 2346-003: 2001 4.2 Construction See table 1. Table 1 Code lumber 004 006 o1 o o1 2 020 030 050 O90 140 220 340 420 530 680 Uominal cross section mm2 o14 05 1 ,o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN23460032001AEROSPACESERIESCABLEELECTRICALFIRERESISTANTOPERATINGTEMPERATURESBETWEEN65DEGREESCAND260DEGREESCPART003DLFAMILYSINGLECOREPRODUCTSTANPDF

链接地址:http://www.mydoc123.com/p-419108.html