AECMA PREN 2346-002-2005 Aerospace Series Cable Electrical Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 002 General Issue P 2《航空航天系列耐火电缆工作温度在-.pdf
《AECMA PREN 2346-002-2005 Aerospace Series Cable Electrical Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 002 General Issue P 2《航空航天系列耐火电缆工作温度在-.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 2346-002-2005 Aerospace Series Cable Electrical Fire Resistant Operating Temperatures between -65 Degrees C and 260 Degrees C Part 002 General Issue P 2《航空航天系列耐火电缆工作温度在-.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication 31 January 2005 prEN 2346-002 Edition P 2 January 2005 Comments should be sent within six months after the date of publication to AECMA-STAN PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES - STANDARDIZATION d%k?&?!f
2、f! Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 81 10 - Fax. + 32 2 775 81 11 - www.aecma-stan.org ICs: 49.060 Descriptors: ENGLISH VERSION Aerospace series Cable, electrical, fire resistant Operating temperatures between - 65 OC and 260 OC Part 002: General Supersedes edition P 1 November 2001
3、 Srie arospatiale Cbles lectriques rsistant au feu Tempratures de fonctionnement comprises entre - 65 OC et 260 OC Partie 002 : Gnralits Luft- und Raumfahrt Feuerbestndige elektrische Leitungen Betriebstemperaturen zwischen - 65 OC und 260 OC Teil 002: Allgemeines This “Aerospace Series“ frestandard
4、 has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequ
5、ent to the publication of this frestandard, the technical content shall not be changed to an extent that interchangeabilify is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of AECMA-STAN, it will be submitt
6、ed as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any
7、 national standards conflicting with the EN. Electrical Domain I I Copytight 2005 O by AECMA-STA1 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page
8、2 prEN 2346-002:2005 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANS Electrical Domain . After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA- STANS General Process Manual. this standard has received approval for Pub
9、lication . Contents 1 2 3 4 5 5.1 5.2 5.2.1 5.2.2 6 7 Scope Normative references . Definitions . List of product standards Materials and construction Materials Construction . Number of cores Colour coding . Identification and marking Technical specification Page 3 3 3 3 4 4 4 4 4 5 5 Copyright Assoc
10、iation Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 prEN 2346-002:2005 1 Scope This standard specifies the list of product standards and common characteristics of
11、fire resistant or fire-proof electrical cables for use in the on-board electrical systems of aircraft at operating temperatures between - 65 “C and 260 “C. (Except otherwise specified in the product standard). 2 Normative references The following referenced documents are indispensable for the applic
12、ation of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. I EC 28: 1925, international standard of resistance for copper. EN 2234, Aerospace series - Cable, electrical, fire
13、resistant - Technical specification I). EN 3475-1 00, Aerospace series - Cables, electrical, aircraft use - Test methods - Part 700: General. EN 3838, Aerospace series - Requirements and tests on user-applied markings on aircraft electrical cables I). TR 6058, Aerospace series - Cable code identific
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN23460022005AEROSPACESERIESCABLEELECTRICALFIRERESISTANTOPERATINGTEMPERATURESBETWEEN65DEGREESCAND260DEGREESCPART002GENERALISSUEP2

链接地址:http://www.mydoc123.com/p-419107.html