1、Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe AASHTO Designation: M 86M/M 86-151ASTM Designation: C14M-07 and C14-07 American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001TS-4a M 86M/
2、M 86-1 AASHTO Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe AASHTO Designation: M 86M/M 86-151ASTM Designation: C14M-07 and C14-07 1. SCOPE 1.1. This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial
3、 wastes, storm water, and for the construction of culverts. 1.2. This specification is applicable for orders in either SI units (M 86M) or in inch-pound units (M 86). SI units and inch-pound units are not necessarily equivalent. Inch-pound units are shown in brackets in the text for clarity, but the
4、y are the applicable values when the material is ordered to M 86. Note 1This specification is a manufacturing and purchasing specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the strength classification of pipe. However,
5、 experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. Owners are cautioned that they must correlate the field requirements
6、 with the class of pipe specified and provide for or require inspection at the construction site. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 6, Fine Aggregate for Hydraulic Cement Concrete M 80, Coarse Aggregate for Hydraulic Cement Concrete M 85, Portland Cement M 194M/M 194, Chemical Admixtu
7、res for Concrete M 240M/M 240, Blended Hydraulic Cement M 262, Concrete Pipe and Related Products M 295, Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete M 302, Slag Cement for Use in Concrete and Mortars T 280, Concrete Pipe, Manhole Sections, or Tile 2.2. ASTM Standards: C309-
8、03, Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete C443, Standard Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets C989/C989M, Standard Specification for Slag Cement for Use in Concrete and Mortars 2015 by the American Association of Sta
9、te Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 86M/M 86-2 AASHTO C990-09, Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants C1116/C1116M, Standard Specific
10、ation for Fiber-Reinforced Concrete 3. TERMINOLOGY 3.1. DefinitionsFor definitions of terms relating to concrete pipe, see M 262. 4. CLASSIFICATION 4.1. Pipe manufactured according to this specification shall be of three classes identified as “Class 1 Nonreinforced Concrete Pipe,” “Class 2 Nonreinfo
11、rced Concrete Pipe,” and “Class 3 Nonreinforced Concrete Pipe.” The corresponding strength requirements are prescribed in Table 1. Table 1 Physical and Dimensional Requirements for Nonreinforced Concrete Pipea Class 1 Class 2 Class 3 Internal Designated Diameter Minimum Thickness of Wall Minimum Str
12、ength, Three-Edge Bearing Minimum Thickness of Wall Minimum Strength, Three-Edge Bearing Minimum Thickness of Wall Minimum Strength, Three-Edge Bearing mm in. mm in. kN/ linear m lbf/ linear ft mm in. kN/ linear m lbf/ linear ft mm in. kN/ linear m lbf/ linear ft 100 4 16 5/8 22.0 1500 19 3/429.0 20
13、00 19 3/435.0 2400 150 6 16 5/8 22.0 1500 19 3/429.0 2000 22 7/835.0 2400 200 8 19 3/422.0 1500 22 7/829.0 2000 29 11/8 35.0 2400 250 10 22 7/823.5 1600 25 1 29.0 2000 32 11/435.0 2400 300 12 25 1 26.5 1800 35 13/833.0 2250 44 13/438.0 2600 375 15 32 11/429.0 2000 41 15/838.0 2600 47 17/842.0 2900 4
14、50 18 38 11/232.0 2200 50 2 44.0 3000 57 21/448.0 3300 525 21 44 13/435.0 2400 57 21/448.0 3300 69 23/456.0 3850 600 24 54 21/838.0 2600 75 3 52.5 3600 85 33/864.0 4400 675 27 82 31/441.0 2800 94 33/457.5 3950 94 33/467.0 4600 750 30 88 31/244.0 3000 107 41/463.0 4300 107 41/469.5 4750 825 33 94 33/
15、446.0 3150 113 41/264.0 4400 113 41/271.0 4875 900 36 100 4 48.0 3300 119 43/465.5 4500 119 43/473.0 5000 a Subject to tolerance in Section 11. 5. BASIS OF ACCEPTANCE 5.1. The acceptability of the pipe shall be determined by the results of the test prescribed in this section, when required, and by i
16、nspection to determine whether the pipe conform to this specification as to design and freedom from defects. 5.2. Acceptance as to Strength PropertiesPipe shall be acceptable under the strength tests when they have met the requirements as prescribed in Section 10.3. 5.3. Acceptance as to Absorption
17、PropertiesPipe shall be acceptable under the absorption test when they have met the requirements as prescribed in Section 10.4. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-4a M 86M/M 86-3 AASHTO 5
18、.4. Acceptance as to Permeability PropertiesPipe shall be acceptable under the permeability test when they have met the requirements as prescribed in Section 10.5. Note 2Prior to purchase, the owner has the option to specify the hydrostatic test prescribed in Section 10.6 instead of the permeability
19、 test. 5.5. Acceptance as to Hydrostatic PropertiesPipe shall be acceptable under the hydrostatic test when they have met the requirements as prescribed in Section 10.6. 6. MATERIALS 6.1. ConcreteThe concrete shall consist of cementitious materials, mineral aggregates, and water. 6.2. Cementitious M
20、aterials: 6.2.1. CementCement shall conform to the requirements for portland cement of M 85 or shall be portland blast-furnace slag cement or slag modified portland cement, or portland-pozzolan cement conforming to the requirements of M 240M/M 240, except that the pozzolan constituent in the Type IP
21、 portland-pozzolan cement shall be fly ash. 6.2.2. Fly AshFly ash shall conform to the requirements of M 295, Class F or Class C. 6.2.3. Ground Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120 of ASTM C989/C989M. 6.2.4. Allowable Combinations of Cement
22、itious MaterialsThe combination of cementitious materials used in the concrete shall be one of the following: 6.2.4.1. Portland cement only, 6.2.4.2. Portland blast-furnace slag cement only, 6.2.4.3. Slag modified portland cement only, 6.2.4.4. Portland-pozzolan cement only, or 6.2.4.5. A combinatio
23、n of portland cement and fly ash. 6.2.4.6. A combination of portland cement and ground granulated blast-furnace slag, or 6.2.4.7. A combination of portland cement, fly ash (not to exceed 25 percent of the total cementitious weight), and ground granulated blast-furnace slag (not to exceed 25 percent
24、of the total cementitious weight). 6.3. AggregatesAggregates shall conform to M 6 and M 80, except that the requirement for gradation shall not apply. 6.4. Admixtures and BlendsAdmixtures and blends shall conform to M 194M/M 194. 6.5. Synthetic and Non-Synthetic FibersFibers are permitted, at the ow
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOM86MM862015STANDARDSPECIFICATIONFORNONREINFORCEDCONCRETESEWERSTORMDRAINANDCULVERTPIPEPDF

链接地址:http://www.mydoc123.com/p-417839.html