AASHTO HB-17 DIVISION II SEC 8-2002 Division II Construction - Concrete Structures《混凝土结构》.pdf
《AASHTO HB-17 DIVISION II SEC 8-2002 Division II Construction - Concrete Structures《混凝土结构》.pdf》由会员分享,可在线阅读,更多相关《AASHTO HB-17 DIVISION II SEC 8-2002 Division II Construction - Concrete Structures《混凝土结构》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、8.1 GENERAL 8.1.1 Description Section 8 CONCRETE STRUCTURES This work shall consist of furnishing, placing, finishing, and curing concrete in bridges, culverts, and miscellaneous structures in accordance with these specifications and conforming to the lines, grades, and dimensions shown on the plans
2、. The work includes elements of structures constructed by cast-in-place and precast methods using either plain (unreinforced), reinforced, or prestressed concrete or any combination thereof. The requirements of this section are not applica- ble to precast box culvert structures, which are addressed
3、in Section 27. quate arrangements will be provided for curing, finishing, and protecting the concrete. 8.2 CLASSES OF CONCRETE 8.2.1 General The class of concrete to be used in each part of the structure shall be as specified or shown on the plans. If not shown or specified, the Engineer will design
4、ate the class of concrete to be used. 8.2.2 Normal Weight Concrete Eight classes of normal weight concrete are provided for in these Specifications as listed in Table 8.2. 8.1.2 Related Work 8.2.3 Lightweight Concrete Other work involved in the construction of concrete structures shall be as specifi
5、ed in the applicable sections of this Specification. Especially applicable are Section 3 for forms and falsework, Section 9 for reinforcing steel, and Section 10 for prestressing. Lightweight concrete shall conform to the require- ments specified in the special provisions or shown on the plans. When
6、 the special provisions require the use of nat- ural sand for a portion or all of the fine aggregate, the nat- ural sand shall conform to AASHTO M 6. 8.1.3 Construction Methods 8.3 MATERIALS Whenever the specifications permit the Contractor to select the method or equipment to be used for any operat
7、ion, it shall be the Contractors responsibility to employ methods and equipment which will produce satisfactory work under the conditions encountered and which will not damage any partially completed portions of the work. Falsework and forms shall conform to the require- ments of Section 3, “Tempora
8、ry Works.” Generally, all concrete shall be fully supported until the required strength and age has been reached. However, the slip form method will be permitted for the construc- tion of pier shafts and railings providing the Contractors plan assures that: (1) the results will be equal in all respe
9、ct to those obtained by the use of fixed forms, and (2) ade- 8.3.1 Cements Portland cements shall conform to the requirements of AASHTO M 85 (ASTM C 150) and Blended Hydraulic cements shall conform to the requirements of AASHTO M 240 (ASTM C 595). For Type 1PPortland-pozzolan ce- ment, the pozzolan
10、constituent shall not exceed 20% of the weight of the blend and the loss on ignition of the poz- zolan shall not exceed 5%. Unless otherwise specified, only Type I, II, or III Port- land Cement, Spes IA, IIA, or IIIAAir Entrained Portland Cement, or Types IP or IS Blended Hydraulic cements shall be
11、used. Types IA, IIA, and IIIA cements may be used only in concrete where air entrainment is required. 525 526 HIGHWAY BRIDGES 8.3.1 TABLE 8.2 Specified Minimum Maximum Air Size of Coarse Compressive Cement WaterICement Content Aggregate Strength Content Ratio Range Per AASHTO M 43 (28 Days) Class of
12、 Pounds Concrete Per CY Lbs Per Lb Percent Square Openings (lb /in. *) 61 1 61 1 517 517 658 65 8 564 658 0.49“ 0.45 0.58 0.55 0.49 0.45 0.49“ 0.58 - 6- 1-1/2 - 5-c 1-1/2 - 7-c 1-1/2 As specified elsewhere - 1 in. to No. 4 1 in. to No. 4 2 in. to No. 3 and 1 in. to No. 4b 2 in. to No. 3 and 1 in. to
13、 No. 4b 1/2 in. to No. 4 1/2 in. to No. 4 1 in. to No. 4 or 3/4 in. to No. 4 1 in. to No. 4 4,000 4,000 2,400 2,400 4,000 4,000 As specified elsewhere - a For concrete in or over saltwater or exposed to deicing chemicals, the maximum waterkement ratio shall be 0.45. Coarse Aggregate for Class B and
14、Class B(AE) shall be furnished in two separate sizes as shown. Low-alkali cements conforming to the requirements of AASHTO M 85 for low-alkali cement shall be used when specified or when ordered by the Engineer as a condition of use for aggregates of limited alkali-silica reactivity. Unless otherwis
15、e permitted, the product of only one mill of any one brand and type of cement shall be used for like elements of a structure that are exposed to view, except when cements must be blended for reduction of any exces- sive air-entrainment where air-entraining cement is used. 8.3.2 Water Water used in m
16、ixing and curing of concrete shall be subject to approval and shall be reasonably clean and free of oil, salt, acid, alkali, sugar, vegetable, or other injurious substances. Water will be tested in accordance with, and shall meet the suggested requirements of AASHTO T 26. Water known to be of potabl
17、e quality may be used with- out test. Where the source of water is relatively shallow, the intake shall be so enclosed as to exclude silt, mud, grass, or other foreign materials. Mixing water for concrete in which steel is embedded shall not contain a chloride ion concentration in excess of 1,000 pp
18、m or sulphates as SO4 in excess of 1,300 ppm. 8.3.3 Fine Aggregate Fine aggregate for concrete shall conform to the re- quirements of AASHTO M 6. 8.3.4 Coarse Aggregate Coarse aggregate for concrete shall conform to the re- quirements of AASHTO M 80. 8.3.5 Lightweight Aggregate Lightweight aggregate
19、 for concrete shall conform to the requirements of AASHTO M 195 (ASTM C 330). 8.3.6 Air-Entraining and Chemical Admixtures Air-entraining admixtures shall conform to the re- quirements of AASHTO M 154 (ASTM C 260). Chemical admixtures shall conform to the require- ments of AASHTO M 194 (ASTM C 494).
20、 Unless other- wise specified, only Type A (Water-reducing), Type B (Retarding), Type D (Water-reducing and retarding), Type F (Water-reducing, high range) or Type G (Water-reduc- ing, high range and retarding) shall be used. 8.3.6 DIVISION II-CONSTRUCTION 527 Admixtures containing chloride ion (Ci)
21、 in excess of 1% by weight of the admixture shall not be used in rein- forced concrete. Admixtures in excess of 0.1% shall not be used in prestressed concrete. A Certificate of Compliance signed by the manufac- turer of the admixture shall be furnished to the Engineer for each shipment of admixture
22、used in the work. Said Certificate shall be based upon laboratory test results from an approved testing facility and shall certify that the ad- mixture meets the above specifications. If more than one admixture is used, the admixtures shall be compatible with each other and shall be incorpo- rated i
23、nto the concrete mix in correct sequence so that the desired effects of all admixtures are obtained. Air-entraining and chemical admixtures shall be incor- porated into the concrete mix in a water solution. The water so included shall be considered to be a portion of the allowed mixing water. For no
24、rmal weight concrete the absolute volume method, such as described in American Concrete Institute Publication 211.1, shall be used in selecting mix propor- tions. For structural lightweight concrete, the mix propor- tions shall be selected on the basis of trial mixes with the cement factor rather th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONIISEC82002DIVISIONIICONSTRUCTIONCONCRETESTRUCTURES 混凝土结构 PDF

链接地址:http://www.mydoc123.com/p-417603.html