BS PD CLC TR 50481-2009 Recommendations on filters nfor shielded enclosures《屏蔽室用过滤器的建议》.pdf
《BS PD CLC TR 50481-2009 Recommendations on filters nfor shielded enclosures《屏蔽室用过滤器的建议》.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TR 50481-2009 Recommendations on filters nfor shielded enclosures《屏蔽室用过滤器的建议》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI British Standards WB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1 Recommendations on filters for shielded enclosures PD CLC/TR 50481:2009National foreword This Published Docum
2、ent is the UK implementation of CLC/TR 50481:2009. The UK participation in its preparation was entrusted by Technical Committee GEL/210, EMC - Policy committee, to Subcommittee GEL/210/12, EMC basic, generic and low frequency phenomena Standardization. A list of organizations represented on this com
3、mittee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2009 ISBN 978 0 580 64194 7 ICS 31.160; 33.100.10 Compliance with a British Standard cannot confer immun
4、ity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee on 3 Ju 2009 Amendments issued since publication Amd. No. Date Text affected BRITISH STANDARD PD CLC/TR 50481:2009 ly 1 TECHNICAL REPORT CLC/TR 50481 RAPPORT TECHNIQUE
5、 TECHNISCHER BERICHT April 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any f
6、orm and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50481:2009 E ICS 33.100.10; 31.160 Supersedes R210-004:1999English version Recommendations on filters for shielded enclosures This Technical Report was approved by CENELEC on 2009-03-20. CENELEC members are the national ele
7、ctrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switz
8、erland and the United Kingdom. PD CLC/TR 50481:2009CLC/TR 50481:2009 2 Foreword This Technical Report was prepared by the Technical Committee CENELEC TC 210, Electromagnetic compatibility (EMC). The text of the draft was submitted to vote in accordance with the Internal Regulations, Part 2, Subclaus
9、e 11.4.3.2 (simple majority) and was approved by CENELEC as CLC/TR 50481 on 2009-03-20. This document supersedes R210-004:1999. _ PD CLC/TR 50481:2009 3 CLC/TR 50481:2009 Contents 1 Scope . 4 2 Normative references . 4 3 Definitions . 4 4 General recommendations on filters 4 5 Insertion loss . 4 5.1
10、 Insertion loss of filters . 4 5.2 Insertion loss values . 5 6 Filter selection . 5 6.1 Choice of filter . 5 6.2 Power line filters . 6 6.3 Signal line filters (including telecom lines) 6 7 Electrical safety. 6 8 Installation of filters 7 Figures Figure 1 Filter insertion loss value a e(typical perf
11、ormance for shielded enclosures) 5 Figure 2 Filter installations schematic 7 PD CLC/TR 50481:2009CLC/TR 50481:2009 4 1 Scope This document was prepared to give users general advices on filtering solutions adopted in shielded enclosures. It is mainly a collection of hints derived from practical exper
12、ience. This document is coordinated with EN 50147-1 and EN 50417-2. The document covers the frequency range DC to 40 GHz. The range above 40 GHz and up to 400 GHz is under consideration. 2 Normative references The following referenced documents are indispensable for the application of this document.
13、 For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050(161), International Electrotechnical Vocabulary (IEV) Chapter 161: Electromagnetic compatibility CISPR 17:1981, Methods of measur
14、ement of the suppression characteristics of passive radio interference filters and suppression components 3 Definitions For the purposes of this document, the terms and definitions given in CISPR 17:1981 apply. 4 General recommendations on filters To prevent interference or over-voltages from being
15、fed into, or out of the shielded enclosure via lines, all lines passing through the shielding must be filtered. In many cases it is not only necessary to protect equipment from broadband interfering signals, but also to limit pulsed type interference (effects of lighting and any man made pulse type
16、phenomena e.g. industrial process). The filter shall not degrade the shielding attenuation of the shielded enclosure. Filters that meet the requirements of the referenced specification below should not be retested after installation because the testing of filters is done in 50 system and shielding i
17、s a measure of transmission loss performed with antennas. If cables that penetrate a shielded enclosure cannot be filtered, they shall have adequate shielding effectiveness and termination on both sides so as to avoid degradation of the shielding effectiveness of the whole installation. Filters are
18、required at each point where an unshielded wire or cable passes through the shielding material of a shielded enclosure. This is to prevent uncontrolled transfer of electromagnetic energy into, or out of, shielded enclosure. 5 Insertion loss 5.1 Insertion loss of filters Practical experience has show
19、n that the insertion loss value of the filters shall be at least as great as the required shield attenuation values of the enclosure. The insertion loss of the filters shall be carefully selected keeping in mind that in the low frequency range (say 100 kHz), the interference is mainly propagated ove
20、r lines (conducted interference). The shielding effectiveness of the filter housing shall not reduce that of the shielded enclosure. PD CLC/TR 50481:2009 5 CLC/TR 50481:2009 5.2 Insertion loss values The insertion loss of the filter is characterised by the lowest attenuation value recorded by three
21、measuring circuits (balanced, unbalanced, asymmetrical) described in CISPR 17. The specified insertion loss value shall be met with the full current load over the entire specified frequency range. During approval measurement of the shielded room, all the cabling of the filters should be noticed and
22、taken into account during the measurement of the shielding attenuation of the enclosure, The filter is expected to attenuate all current lines and neutral by frequency dependent factor while the power frequency attenuation should approach zero. Signal filters shall behave in the same manner as above
23、 and particular attention is to be paid to the low band, pass band and high band (e.g. of shielded cables). Measurement configuration B3 and B4 of CISPR 17. Figure 1 Filter insertion loss value a e(typical performance for shielded enclosures) 6 Filter selection In the case of filters with current co
24、mpensated chokes, steps should be taken to ensure that the outgoing and return lines are routed through the same filter. If artificial mains networks (according to EN 55016 series) or coupling/decoupling networks for immunity tests are installed in shielded rooms, the use of filters with current com
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTR504812009RECOMMENDATIONSONFILTERSNFORSHIELDEDENCLOSURES 屏蔽 过滤器 建议 PDF

链接地址:http://www.mydoc123.com/p-397571.html