1、Designation: C1015 17Standard Practice forInstallation of Cellulosic and Mineral Fiber Loose-FillThermal Insulation1This standard is issued under the fixed designation C1015; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This practice covers procedu
3、res for the installation ofcellulosic and mineral fiber loose-fill insulation in ceilings,attics, and floor and wall cavities of new or existing housingand other framed buildings.1.2 This practice applies only to the installation of dryloose-fill thermal insulation consisting of cellulosic materials
4、or mineral fiber by pneumatic or pouring application.1.3 This practice covers the installation process from pre-installation inspection through post-installation procedure. Itdoes not cover the production of the insulation materials.1.4 This practice is not intended to replace the manufactur-ers ins
5、tallation instructions, but shall be used in conjunctionwith such instructions. This practice is not intended to super-sede local, state, or federal codes.1.5 This practice assumes that the installer possesses a goodworking knowledge of the applicable codes and regulations,safety practices, tools, e
6、quipment, and methods necessary forthe installation of thermal insulation materials. It also assumesthat the installer understands the fundamentals of residentialconstruction that affect the installation of insulation.1.6 The values stated in inch-pound units are to be regardedas standard. The value
7、s given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to estab
8、lish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 5.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC739 Specification for Cellulosic Fiber
9、 Loose-Fill ThermalInsulationC755 Practice for Selection of Water Vapor Retarders forThermal InsulationC764 Specification for Mineral Fiber Loose-Fill ThermalInsulation2.2 NFPA Standards:3NFPA31 Standard for the Installation of Oil Burning Equip-mentNFPA 54 National Fuel Gas CodeNFPA 70 National Ele
10、ctrical CodeNFPA 211 Standard for Chimneys, Fireplaces, Vents andSolid-Fuel Burning Appliances2.3 ICC Document:4International Residential Code 20032.4 Federal Standard:5FTC Trade Regulation Rule 16 CRF 460 Labeling andAdvertising of Home Insulation3. Terminology3.1 DefinitionsFor definitions of term
11、s used in thispractice, see Terminology C168.3.2 Definitions of Terms Specific to This Standard:3.2.1 installerthe person or persons who apply thermalinsulation materials in residential buildings whether or not suchperson or persons have contracted with the owner to performthe work.1This practice is
12、 under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.23 on Blanket andLoose Fill Insulation.Current edition approved March 15, 2017. Published March 2017. Originallyapproved in 1984. Last previous edition approved in 2011 as C1015 06
13、 (2011)1.DOI: 10.1520/C1015-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Fire
14、Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.4Available from International Code Council (ICC), 500 New Jersey Ave., NW,6th Floor, Washington, DC 20001, http:/www.iccsafe.org.5Federal Register Vol 70, No 103, May 31, 2005. Available from NationalArchive
15、s and Records Administration, 8601 Adelphi Road, College Park Maryland,207406001.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on stan
16、dardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.2.2 cellulosic loose-fill thermal insulating materialsthose materials that meet the mi
17、nimum requirements specifiedin Specification C739.3.2.3 conditioned spacea space in a residential buildingthat is served by a heating or cooling system.3.2.4 mineral fiber loose-fill thermal insulating materialsthose materials that meet the minimum requirements specifiedin Specification C764.3.2.5 o
18、wnerthe person, partnership, corporation, agency,or other entity who owns the residential building to beinsulated whether such ownership is by virtue of deed,contract, or any other instrument for acquiring legal title underthe laws of the state in which the building is located.3.2.6 residential buil
19、dinga building used for residentialoccupancy and that has a mechanical or electrical system forheating or for cooling, or for both.3.2.7 vapor retardera material (membrane or paint) thathas a water vapor permeance rating of 1 perm (5.7 108/Pasm2) or less. See Practice C755 for more information onvap
20、or retarders.4. Significance and Use4.1 This practice recognizes that effectiveness, safety, anddurability of insulation depend not only on the quality of theinsulating materials, but also on their proper installation.4.2 Improper installation of insulation can reduce its ther-mal effectiveness, cau
21、se fire risks and other unsafe conditions,and promote deterioration for the structure in which it isinstalled. Specific hazards that can result from improperinstallation include fires caused by (1) heat build-up in recessedlighting fixtures; (2) deterioration or failure of electrical wiringcomponent
22、s; (3) heat build-up resulting from overcurrentprotection devices incorrectly matched to wiring; or (4) dete-rioration in wood structures and paint failure due to moistureaccumulation.4.3 This practice provides general procedures that will helpensure the installation of insulation in a safe and effe
23、ctivemanner. It must be noted that actual conditions in existingbuildings vary greatly, and in some cases substantial additionalcare and precaution must be taken to ensure effective and safeinstallation.5. Safety Precautions5.1 All pneumatic equipment shall be operated in accor-dance with the recomm
24、ended operating and safety proceduresof the equipment manufacturer and the insulation manufac-turer.5.2 The installer shall wear proper clothing and equipmentas recommended by the insulation manufacturer. If in doubt ofthe effects of the insulation, wear protective clothing, gloves,eye and breathing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM C1015-17 Standard Practice for Installation of Cellulosic and Mineral Fiber Loose-Fill Thermal Insulation C1015

链接地址:http://www.mydoc123.com/p-348192.html