1、Designation: D1739 98 (Reapproved 2017)Standard Test Method forCollection and Measurement of Dustfall (SettleableParticulate Matter)1This standard is issued under the fixed designation D1739; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for collection ofdustfall and its measurement. This test meth
3、od is not appro-priate for determination of the dustfall rate in small areasaffected by specific sources. This test method describes deter-mination of both water-soluble and insoluble particulate mat-ter.1.2 This test method is inappropriate for industrial hygieneuse except where other more specific
4、 methods are also used.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this sta
5、ndard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B57 Specification for Copper-Alloy Condenser Tube Plates;Replaced by B 171 (Withdrawn 1941)3D1193 Specification for Reagent W
6、aterD1356 Terminology Relating to Sampling and Analysis ofAtmospheresE11 Specification for Woven Wire Test Sieve Cloth and TestSievesIEEE/ASTM SI-10 American National Standard for Use ofthe International System of Units (SI): The Modern MetricSystem3. Terminology3.1 DefinitionsFor definitions of ter
7、ms used in this testmethod, refer to Terminology D1356. An explanation of units,symbols, and conversion factors may be found in PracticeE380.3.2 Definitions of Terms Specific to This Standard:3.2.1 settleable particulate materialany material com-posed of particles small enough to pass through a 1-mm
8、 screen(see Specification E11) and large enough to settle by virtue oftheir weight into the container from the ambient air.4. Summary of Test Method4.1 Containers of a standard size and shape are prepared andsealed in a laboratory and then opened and set up at appropri-ately chosen sites so that par
9、ticulate matter can settle into themfor periods of about 30 days. The containers are then closedand returned to the laboratory. The masses of the water-solubleand -insoluble components of the material collected are deter-mined. The results are reported as grams per square metre per30 days g/(m230d).
10、5. Significance and Use5.1 This test method has the advantage of extreme simplic-ity. It is a crude and non-specific test method, but it is useful inthe study of long-term trends. It requires very little investmentin equipment and can be carried out without a largetechnically-skilled staff.5.2 This
11、test method is useful for obtaining samples ofsettleable particulate matter for further chemical analysis (1).46. Interferences6.1 The results from this test method are obtained byweighings. Any material that gets into the container and passesthrough the sieve used in analysis, but which did not set
12、tle intothe container after air entrainment can be considered aninterferent.7. Apparatus7.1 ContainerAn open-topped cylinder not less than 150mm 6 in. in diameter with height not less than twice its1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct resp
13、onsibility of Subcommittee D22.03 on AmbientAtmospheres and Source Emissions.Current edition approved March 1, 2017. Published March 2017. Originallyapproved in 1960. Last previous edition approved in 2010 as D1739 98 (2010).DOI: 10.1520/D1739-98R17.2For referenced ASTM standards, visit the ASTM web
14、site, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4The boldface numbers in pa
15、rentheses refer to the list of references at the end ofthis test method.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardizati
16、on established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1diameter. Containers should be made of stainless steel orweatherproof plastic. They shall be capa
17、ble of acceptinglegible, weatherproof, identification markings. A tight-fittinglid is needed for each container.7.2 Stand, for the container, which will hold the top of thecontainer at a height of 2 m above ground. It will also includea wind shield constructed in accordance with Figs. 1 and 2.Experi
18、ments reported in Kohler and Fleck (2) indicate thatmuch better precision is obtained when this simple aerody-namic shield is provided, and that there is a wide variability inthe concentration of particles subject to settling at heights ofless than 2 m.7.3 Sieve, 1 mm (No. 18), stainless steel.7.4 D
19、rying Oven, with temperature controlled at 105C.7.5 Buchner Funnel, and 2 L filtering flask.7.6 Filter Paper, fast filtering type, circles to fit the Buchnerfunnel.7.7 Evaporating Dishes, 100-mL capacity, capable of beingunambiguously identified.7.8 Desiccators.7.9 Analytical Balance, to weigh with
20、a precision of 60.1mg.7.10 Flexible Spatula.7.11 Crate, or frame in which to carry the containers.7.12 Graduated Cylinder, 1 L capacity, whose graduationshave been checked for calibration accuracy, 65 mL, using, forexample, volumetric flasks or pipettes.8. Reagents8.1 Purity of WaterUnless otherwise
21、 indicated, referenceto water shall be understood to mean reagent water as definedby Type II of Specification D1193.9. Sampling9.1 Sites (3, 4); for general sampling strategy, see Specifi-cations B57.9.1.1 Location:9.1.1.1 These recommendations are a guide to the selectionof a site. In cases where t
22、hese guidelines cannot be followed,results should only be presented accompanied by an appropri-ate caveat.9.1.1.2 The sampling site should be in an open area, free ofstructures higher than 1 m within a 20-m radius of the containerstand. It should be away from local sources of pollution andobjects th
23、at could affect the settling of particulate matter, suchas trees, and air exhausts and intakes.Accessibility and securityfrom vandalism are major considerations in the selection of asite.9.1.1.3 Elevations to higher objects within 20 m should notexceed 30 from the horizontal.9.1.1.4 Open areas aroun
24、d police and fire stations andlibraries are often suitable because of their accessibility andsecurity.9.1.1.5 Avoid sitting the containers near chimneys. When-ever possible, the sampling site shall be more than tenstack-lengths from an operating stack and upwind from it inaccordance with the most fr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D1739 98 2017 Standard Test Method for Collection and Measurement of Dustfall Settleable Particulate Matter

链接地址:http://www.mydoc123.com/p-294266.html