ASTM F558-17a Standard Test Method for Measuring Air Performance Characteristics of Vacuum Cleaners.pdf
《ASTM F558-17a Standard Test Method for Measuring Air Performance Characteristics of Vacuum Cleaners.pdf》由会员分享,可在线阅读,更多相关《ASTM F558-17a Standard Test Method for Measuring Air Performance Characteristics of Vacuum Cleaners.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F558 17a An American National StandardStandard Test Method forMeasuring Air Performance Characteristics of VacuumCleaners1This standard is issued under the fixed designation F558; the number immediately following the designation indicates the year of originaladoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for determining airperformance characteristics of commercial
3、and householdupright, canister, stick, hand-held, utility, and combination-type vacuum cleaners having provisions for attaching a hoseand incorporating a series universal motor. This test methodcan be applied to the carpet cleaning mode of operation.1.2 These tests and calculations include determina
4、tion ofsuction, airflow, air power, maximum air power, and inputpower under standard operating conditions (see Note 1). Thenozzle mounted on plenum testing is an ideal air performancemeasurement and is not intended to represent the actual airperformance during carpet or floor cleaning.NOTE 1For more
5、 information on air performance characteristics, seeRefs (1-6).21.3 The foot-pound-inch system of units is used in thisstandard. The values in parentheses are given for informationonly.1.4 This standard may involve hazardous materials,operations, and equipment. This standard does not purport toaddre
6、ss all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety, health, and environmental prac-tices and determine the applicability of regulatory limitationsprior to use. A specific precautionary statement is given
7、 inNote 2.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalB
8、arriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3E1 Specification for ASTM Liquid-in-Glass ThermometersE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE
9、2251 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision LiquidsF431 Specification for Air Performance Measurement Ple-num Chamber for Vacuum Cleaners2.2 AMCA Standard:4210-85 Laboratory Methods of Testing Fans for Rating2.3 IEC Standard:5IEC 62885-2 Surface Cleaning Appli
10、ances Part 2: DryVacuum Cleaners for Household or Similar Use Meth-ods for Measuring the Performance3. Terminology3.1 Definitions:3.1.1 air power, AP, W, nin a vacuum cleaner, the net timerate of work performed by an air stream while expendingenergy to produce an airflow by a vacuum cleaner underspe
11、cified air resistance conditions.3.1.2 automatic bleed valve, nany device a part of avacuum cleaners design which automatically introduces anintentional leak within the vacuum cleaners system whenmanufacturer specified conditions are met.3.1.3 corrected airflow, Q, cfm, nin a vacuum cleaner, thevolu
12、me of air movement per unit of time under standardatmospheric conditions.3.1.4 input power, W, nthe rate at which electrical energyis absorbed by a vacuum cleaner.1This test method is under the jurisdiction of ASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.
13、22 on Air Perfor-mance.Current edition approved Sept. 1, 2017. Published October 2017. Originallyapproved in 1978. Last previous edition approved in 2017 as F558 17. DOI:10.1520/F0558-17A.2The boldface numbers in parentheses refer to the list of references appended tothis test method.3For referenced
14、 ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available fromAir Movement and ControlAssociation, 30 West University Dr.,A
15、rlington Heights, IL, 60004.5Available from the IEC Web store, webstore.iec.ch, or American NationalStandards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis internat
16、ional standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Commit
17、tee.13.1.5 model, nthe designation of a group of vacuumcleaners having the same mechanical and electrical construc-tion with only cosmetic or nonfunctional differences.3.1.6 population, nthe total of all units of a particularmodel vacuum cleaner being tested.3.1.7 repeatability limit (r), nthe value
18、 below which theabsolute difference between two individual test results obtainedunder repeatability condition may be expected to occur with aprobability of approximately 0.95 (95 %).3.1.8 repeatability standard deviation (Sr), nthe standarddeviation of test results obtained under repeatability condi
19、-tions.3.1.9 reproducibility limit (R), nthe value below which theabsolute difference between two test results obtained underreproducibility conditions may be expected to occur with aprobability of approximately 0.95 (95 %).3.1.10 reproducibility standard deviation (SR), nthe stan-dard deviation of
20、test results obtained under reproducibilityconditions.3.1.11 sample, na group of vacuum cleaners taken from alarge collection of vacuum cleaners of one particular modelwhich serves to provide information that may be used as a basisfor making a decision concerning the larger collection.3.1.12 standar
21、d air density, std, lb/ft3,natmospheric airdensity of 0.075 lb/ft3(1.2014 Kg/m3).3.1.12.1 DiscussionThis value of air density correspondsto atmospheric air at a temperature of 68F (20C), 14.696 psi(101.325 kPa), and approximately 30 % relative humidity.3.1.13 suction, inch of water, nin a vacuum cle
22、aner, theabsolute difference between ambient and subatmospheric pres-sure.3.1.14 test run, nthe definitive procedure that producesthe singular result of calculated maximum air power.3.1.15 test station pressure, Bt, inch of mercury, nfor avacuum cleaner, the absolute barometric pressure at the testl
23、ocation (elevation) and test time.3.1.15.1 DiscussionIt is not the equivalent mean sea levelvalue of barometric pressure typically reported by the airportand weather bureaus. It is sometimes referred to as theuncorrected barometric pressure (that is, not corrected to themean sea level equivalent val
24、ue). Refer to 5.5 for additionalinformation.3.1.16 unit, na single vacuum cleaner of the model beingtested.4. Significance and Use4.1 The test results allow the comparison of the maximumpotential air power available for cleaning tasks when testedunder the conditions of this test method. The test res
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM F558 17 Standard Test Method for Measuring Air Performance Characteristics of Vacuum Cleaners

链接地址:http://www.mydoc123.com/p-291214.html