ASTM E970-17 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source.pdf
《ASTM E970-17 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source.pdf》由会员分享,可在线阅读,更多相关《ASTM E970-17 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E970 17 An American National StandardStandard Test Method forCritical Radiant Flux of Exposed Attic Floor Insulation Usinga Radiant Heat Energy Source1This standard is issued under the fixed designation E970; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This fire-test-response standard describes a procedurefor measurin
3、g the critical radiant flux of exposed attic floorinsulation subjected to a flaming ignition source in a gradedradiant heat energy environment in a test chamber. Thespecimen is any attic floor insulation. This test method is notapplicable to those insulations that melt or shrink away whenexposed to
4、the radiant heat energy environment or the pilotburner.1.2 This fire-test-response standard measures the criticalradiant flux at the point at which the flame advances thefarthest. It provides a basis for estimating one aspect of fireexposure behavior for exposed attic floor insulation. Theimposed ra
5、diant flux simulates the thermal radiation levelslikely to impinge on the floors of attics whose upper surfacesare heated by the sun through the roof or by flames from anincidental fire in the attic. This fire-test-response standard wasdeveloped to simulate an important fire exposure component offir
6、es that develop in attics, but is not intended for use inestimating flame spread behavior of insulation installed otherthan on the attic floor.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.4 The text of this standard refere
7、nces notes and footnotesthat provide explanatory information. These notes andfootnotes, excluding those in tables and figures, shall not beconsidered as requirements of this standard.1.5 This standard is used to measure and describe theresponse of materials, products, or assemblies to heat andflame
8、under controlled conditions, but does not by itselfincorporate all factors required for fire hazard or fire riskassessment of the materials, products, or assemblies underactual fire conditions.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. I
9、t is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.7 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(
10、excluding those in tables and figures) shall not be consideredas requirements of the standard.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Stan
11、dards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC665 Specification for Mineral-Fiber Blanket Thermal Insu-l
12、ation for Light Frame Construction and ManufacturedHousingC739 Specification for Cellulosic Fiber Loose-Fill ThermalInsulationC764 Specification for Mineral Fiber Loose-Fill ThermalInsulationE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE122 Practice for Calculating Sample
13、Size to Estimate, WithSpecified Precision, the Average for a Characteristic of aLot or ProcessE176 Terminology of Fire StandardsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE631 Terminology of Building ConstructionsE648 Test Method for Critical Radiant Flux of Floor-Cover
14、ing Systems Using a Radiant Heat Energy Source1This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.22 on SurfaceBurning.Current edition approved July 1, 2017. Published July 2017. Originally approvedin 1983. Last prev
15、ious edition approved in 2014 as E970 14. DOI: 10.1520/E0970-17.2For referened ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websit
16、e.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization es
17、tablished in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE2653
18、Practice for Conducting an Interlaboratory Study toDetermine Precision Estimates for a Fire Test Methodwith Fewer Than Six Participating Laboratories2.2 Federal Specifications:HH-I-515 Insulation Thermal (Loose Fill for Pneumatic orPoured Application), Cellulosic or Wood Fiber3HH-I-521, Insulation B
19、lankets, Thermal (Mineral Fiber, forAmbient Temperature)3HH-I-1030 Insulation, Thermal (Mineral Fiber, for Pneu-matic or Poured Application)33. Terminology3.1 For definitions of terms used in this test method andassociated with fire issues refer to the terminology contained inTerminology E176.3.2 De
20、finitions:3.2.1 attic, nan accessible enclosed space in a buildingimmediately below the roof and wholly or partly within theroof framing.3.2.2 See Terminology E631 for additional definitions ofterms used in this test method.3.3 Definitions of Terms Specific to This Standard:3.3.1 critical radiant fl
21、ux, nthe level of incident radiantheat energy on the attic floor insulation system at the mostdistant flame-out point. It is reported as W/cm2(or Btu/ft2s).3.3.2 radiant flux profile, nthe graph relating incidentradiant heat energy on the specimen plane to distance from thepoint of initiation of fla
22、ming ignition, that is, 0 mm.3.3.3 total flux metre, nthe instrument used to measure thelevel of radiant heat energy incident on the specimen plane atany point.4. Summary of Test Method4.1 A horizontally mounted insulation specimen is exposedto the heat from an air-gas radiant heat energy panel loca
23、tedabove and inclined at 30 6 5 to the specimen. After a shortpreheat, the hottest end of the specimen is ignited with a smallcalibrated flame. The distance to the farthest advance offlaming is measured, converted to kilowatts per square meterfrom a previously prepared radiant flux profile graph, an
24、dreported as the critical radiant flux.5. Significance and Use5.1 This fire-test-response standard is designed to provide abasis for estimating one aspect of the fire exposure behavior toexposed insulation installed on the floors of building attics. Thetest environment is intended to simulate condit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E970 17 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using Heat Energy Source

链接地址:http://www.mydoc123.com/p-288747.html