ASTM E580E580M-17 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions.pdf
《ASTM E580E580M-17 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions.pdf》由会员分享,可在线阅读,更多相关《ASTM E580E580M-17 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E580/E580M 17Standard Practice forInstallation of Ceiling Suspension Systems for AcousticalTile and Lay-in Panels in Areas Subject to EarthquakeGround Motions1This standard is issued under the fixed designation E580/E580M; the number immediately following the designation indicates the y
2、earof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. D
3、epartment of Defense.1. Scope*1.1 This practice covers the installation of suspended sys-tems for acoustical tile and lay-in panels and their additionalrequirements for two groups of buildings that are constructedto resist the effects of earthquake motions as defined by ASCE7 and the International B
4、uilding Code. These groupings are forSeismic Design Category C and Seismic Design Categories D,E and F.1.2 The authority having jurisdiction shall determine theapplicability of this practice.1.3 Test Methods E3090/E3090M, Specification C635, andPractice C636 cover suspension systems, their installat
5、ion, andtesting without special regard to seismic lateral restraint needs.They remain applicable and shall be followed when thispractice is specified.1.4 Ceilings less than or equal to 144 ft213.4 m2 andsurrounded by walls connected to the structure above areexempt from the requirements of this prac
6、tice.1.5 This practice is not intended to stifle research anddevelopment of new products or methods. This practice is notintended to prevent the installation of any material or prohibitany design or method of construction not prescribed in thispractice, provided that any such alternative has been su
7、bstan-tiated by verifiable engineering data or full-scale dynamictesting that is acceptable to the authority having jurisdiction.1.6 Ceiling areas of 1000 ft292.9 m2 or less shall beexempt from the lateral force bracing requirements of 5.2.8.1.7 Ceilings constructed of gypsum board which is screw or
8、nail attached to suspended members that support a ceiling onone level extending from wall to wall shall be exempt from therequirements of this practice.1.8 Free floating ceilings (those not attached directly to anystructural walls) supported by chains or cables from thestructure are not required to
9、satisfy the seismic force require-ments provided they meet the following requirements:1.8.1 The design load for such items shall equal 1.4 timesthe vertical operating weight.1.8.2 Seismic interaction effects shall be considered inaccordance with 5.7.1.8.3 The connection to the structure shall allow
10、a 360range of motion in the horizontal plane.1.9 The values stated in either inch-pound or SI units are tobe regarded as standard. Within the text, the SI units are shownin brackets. The values stated in each system are not exactequivalents; therefore, each system shall be used independentlyof the o
11、ther. Combining values from the two systems result innonconformance with the specification.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and env
12、ironmental practices and deter-mine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Stan
13、dards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C635 Specification for the Manufacture, Performance, andTesting of Metal Suspension Systems for Acoustical Tileand Lay-in Panel CeilingsC636
14、 Practice for Installation of Metal Ceiling Suspension1This practice is under the jurisdiction of ASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.04 on Application of Acoustical Materials and Systems.Current edition approved Sept. 1, 2017
15、. Published September 2017. Originallyapproved in 1976. Last previous edition approved in 2016 as E580/E580M 16.DOI: 10.1520/E0580_E0580M-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volu
16、me information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed
17、in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Systems for Acoustical T
18、ile and Lay-In PanelsE3090/E3090M Test Methods for Strength Properties ofMetal Ceiling Suspension Systems2.2 Other Standards:ASCE 7 Minimum Design Loads for Buildings and OtherStructures3CISCA Recommendations for Direct-hung Acoustical Tileand Lay-in Ceilings, Seismic Zones 0-24CISCA Guidelines for
19、Seismic Restraint for Direct HungSuspended Ceiling Assemblies, Seismic Zones3&44International Building Code5NFPA 70 National Electric Code63. Significance and Use3.1 This practice is a prescriptive set of installation methodsto be used for suspended ceilings and is often used in lieu ofdesigning a s
20、eparate lateral restraint system. The authorityhaving jurisdiction shall determine the applicability of thispractice to local code requirements.3.2 This practice covers installation of suspended ceilingsystems and related components in areas that require resistanceto the effects of earthquake motion
21、s as defined by ASCE 7 andthe International Building Code.3.3 The practice is broken into two main sections. The firstsection covers areas with light to moderate earthquake poten-tial (Seismic Design Category C) while the second deals withsevere earthquake potential (Seismic Design Category D, E &F)
22、.3.4 This practice includes requirements from multiplesources including previous versions of this practice, CISCASeismic Recommendations for Direct-hungAcoustical Tile andLay-in Ceilings, Seismic Zones 0-2 and CISCA Guidelines forSeismic Restraint for Direct Hung Suspended CeilingAssemblies, Seismic
23、 Zones3&4,suspended ceiling require-ments from the International Building Code and ASCE 7. Thepurpose is to combine the requirements from these sources intoa single comprehensive document.4. Seismic Design Category CNOTE 1This section is intended to provide an unrestrained (free-floating) ceiling sy
24、stem that will accommodate the movement of thestructure during a seismic event.4.1 Suspension System Components:4.1.1 The recommendations in this section are for ceilingssystems with an average weight over the entire ceiling of 2.5lb/ft212 N/m2 or less. This average weight includes suspen-sion membe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E580E580M 17 Standard Practice for Installation of Ceiling Suspension Systems Acoustical Tile and Lay in Panels Areas Subject to Earthquake Ground Motions

链接地址:http://www.mydoc123.com/p-287132.html