1、Designation: E1044 96 (Reapproved 2018)Standard Specification forGlass Serological Pipets (General Purpose and Kahn)1This standard is issued under the fixed designation E1044; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers glass serological pipets, usedin measuring volumes of liquids.1.2 This international st
3、andard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2.
4、 Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory ApparatusE542 Practice for Calibration of Laboratory VolumetricApparatusE671 Specification for Maximum Permissible Thermal Re-sidual Stress in Annealed Glass Laboratory ApparatusE694 Specification for Laboratory Gl
5、ass Volumetric Appa-ratusE920 Specification for Commercially Packaged LaboratoryApparatusE921 Specification for Export Packaged Laboratory Appa-ratusE1133 Practice for Performance Testing of Packaged Labo-ratory Apparatus for United States Government Procure-mentsE1157 Specification for Sampling and
6、 Testing of ReusableLaboratory Glassware3. Classification3.1 Style and CapacityPipets covered by this specificationshall be of the following styles and capacities:3.1.1 Style IGeneral purpose top end.3.1.2 Style IICotton plugging top end.3.1.3 Style IIICotton plugging top end, large tip opening.3.1.
7、4 Capacities (mL)0.1; 0.1 (Kahn); 0.2; 0.2 (Kahn);0.25 (Kahn); 0.5; 0.60 (Kahn); 1.0; 2.0; 5.0; 10.0; and 25.0.4. General Requirements4.1 Borosilicate GlassBorosilicate glass for pipets shallconform to the glass requirements of Type 1, Class A or B ofSpecification E438.4.2 CalibrationPipets shall be
8、 calibrated in accordancewith Practice E542 to deliver (TD) the intended capacity ofdistilled water at 20C when the last drop is blown out, exceptthe 0.25 mL Kahn pipet; this Kahn pipet shall have a clearungraduated space of not less than 63 mm between thelowermost graduation mark and the tip of the
9、 pipet. The pipetshall be filled about 10 mm above the capacity line. Removeany water on the outside of the tip by a downward wipe withfilter paper. Next, place the tip in contact with the wetted wallof a beaker and slowly lower the meniscus to the capacity line.Do not remove any water remaining on
10、the tip at this time.Delivery of the contents into a receiving vessel is made withthe tip in contact with the wall of the vessel. When the waterhas ceased to flow, the water remaining in the tip is then blownout with one firm puff with the tip in contact with the wall ofthe vessel, if possible. No a
11、fter-drainage period is allowed.Capacity tolerances shall be within the limits given in Table 1.4.3 AnnealingThe maximum residual thermal stress shallbe such as to conform to Specification E671, except thattempered tips or tempered tops, or both, may be supplied at theoption of the manufacturer. The
12、 tempered tip, when examinedin index oil that matches the refractive index of the glass beingused, shall have a temper between 75 and 220 nm.5. Design5.1 ShapeThe pipets shall be straight and of one-piececonstruction. Any cross section of a pipet taken in a planeperpendicular to the longitudinal axi
13、s shall be circular.5.2 Delivery TipsDelivery tips shall be made with agradual taper of 15 to 30 mm for capacities up to 5 mLinclusive, and 20 to 35 mm for 10 and 25 mL capacity pipets.The end of the tip shall be perpendicular to the longitudinalaxis of the pipet. Sudden constriction at the orifice
14、shall not be1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onLaboratory Ware and Supplies.Current edition approved Jan. 1, 2018. Published January 2018. Originallyapproved in 1985. Last previous editi
15、on approved in 2011 as E1044 96 (2011).DOI: 10.1520/E1044-96R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websi
16、te.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of In
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E1044 96 2018 Standard Specification for Glass Serological Pipets General Purpose and Kahn

链接地址:http://www.mydoc123.com/p-287028.html