ASTM D6705D6705M-04(2018) Standard Guide for Repair and Recoat of Spray Polyurethane Foam Roofing Systems.pdf
《ASTM D6705D6705M-04(2018) Standard Guide for Repair and Recoat of Spray Polyurethane Foam Roofing Systems.pdf》由会员分享,可在线阅读,更多相关《ASTM D6705D6705M-04(2018) Standard Guide for Repair and Recoat of Spray Polyurethane Foam Roofing Systems.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6705/D6705M 04 (Reapproved 2018)Standard Guide forRepair and Recoat of Spray Polyurethane Foam RoofingSystems1This standard is issued under the fixed designation D6705/D6705M; the number immediately following the designation indicates theyear of original adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the procedures for the repair andrecoating of existing spray polyurethane roofing
3、 systems.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conform
4、ancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory li
5、mitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organizati
6、on TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C1029 Specification for Spray-Applied Rigid Cellular Poly-urethane Thermal InsulationD5469/D5469M Guide for Application of New Spray Ap-plied Polyurethane Foam and Coated Roofing SystemsD6083 Specification for L
7、iquid Applied Acrylic CoatingUsed in Roofing (Withdrawn 2014)32.2 SPFA Standards:4AY 102 A Guide for Selection of Elastomeric ProtectiveCoatings Over Sprayed Polyurethane FoamAY 107 Spray Polyurethane Foam Blisters, Their Causes,Types, Prevention and Repair2.3 CPI Standard:5Center for The Polyuretha
8、ne Industry (CPI), Bulletin AX119 Guide for Safe Handling and Use of Polyurethaneand Polyisocyanurate Foam Systems3. Terminology3.1 Definitions:3.1.1 recoatto apply a new protective coating over anexisting coated SPF (spray polyurethane foam) roof system toextend the performance life of the roofing
9、system.3.1.2 scarfingto shave or grind an SPF foam surfacemechanically to remove a coating, or UV deteriorated SPF, orboth, to refoam or recoat the surface.4. Significance and Use4.1 This guide outlines general procedures and precautionsnecessary for correct and safe repair and recoat of SPF roofing
10、systems.4.2 This guide is not all inclusive; this guide is intended tosupplement detailed instructions from manufacturers andsafety requirements required by law.5. Roof Inspection Procedures and Considerations5.1 General Considerations:5.1.1 The performance of a sprayed-in-place polyurethanefoam roo
11、f system can be affected by all the component parts ofthe roof structure, as well as the atmospheric conditions insideand outside the structure. Structural design, code compliance,specification review, contractor, and material selection shouldbe considered in the repair and recoat of a spray polyure
12、thanefoam roof system.1This guide is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.06 on SprayPolyurethane Foam Roof Systems.Current edition approved Jan. 1, 2018. Published January 2018. Originallyapproved in 2001. Last
13、 previous edition approved in 2011 as D6705/D6705M 04(2011)1. DOI: 10.1520/D6705_D6705M-04R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document
14、 Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from Spray Polyurethane Foam Alliance, 4400 Fair Lakes Ct., Suite105, Fairfax, VA 22033.5Available from The Center for the Polyurethanes Industry, 1300 Wilson Blvd.,Arlingt
15、on, VA 22209.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelop
16、ment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.1.2 A range of spray polyurethane foam systems existswith various physical properties, exhibiting different tempera-ture limitations, and different combus
17、tibility characteristics.Most published data are obtained from testing of laboratorysamples. The thickness of the polyurethane foam sprayed,number of passes, temperature of substrate, ambienttemperature, and so forth will have an effect on all polyure-thane foam properties.5.1.3 The specifier should
18、 consult with the respective ma-terial manufacturer of the sprayed-in-place polyurethane foamroof system. This should include, but not be limited to,materials selection, expansion joints, flashing details, and otheritems.5.2 Inspection:5.2.1 The preparation for the repair and recoat of a sprayed-in-
19、place polyurethane foam roof system will vary according tothe conditions of the roof and its component parts and the typeof existing protective coating used over the polyurethane foam.5.2.2 Conduct a roof inspection to determine the repairs tobe performed and the type of materials to be used.5.3 Vis
20、ual Inspection:5.3.1 Look for blisters or delaminated areas in the originalroof.5.3.2 Check the condition of the roofing system at allflashing and termination points.5.3.3 Look for damage that would affect recoating of theroofing system.5.3.4 Check for pinholes in the polyurethane foam, orcoating, o
21、r both.5.3.5 Check for exposed polyurethane foam and areas oferoded coating.5.3.6 Check for areas of ponding water.5.4 Physical Inspection:5.4.1 Perform a nondestructive moisture survey. Follow upsuspected moisture-laden areas with a moisture probe or coresamples.5.4.2 Take slit samples of the exist
22、ing system as required bythe new coating manufacturer.5.4.3 Take polyurethane foam core samples as required bythe SPF, or coating manufacturer, or both.5.5 Analyze Inspection:5.5.1 Core and slit samples should be examined for thefollowing characteristics:5.5.1.1 Adhesion of polyurethane foam to the
23、substrate,5.5.1.2 Interlaminar adhesion of polyurethane foam,5.5.1.3 Presence of moisture,5.5.1.4 Adhesion of base coat to polyurethane foam,5.5.1.5 Adhesion of top coat to base coat,5.5.1.6 Type and condition of protective coating, and5.5.1.7 Thickness of protective coating.5.5.2 On a roof sketch,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D6705D6705M 04 2018 Standard Guide for Repair and Recoat of Spray Polyurethane Foam Roofing Systems

链接地址:http://www.mydoc123.com/p-286962.html