《ASTM D5315-04(2017)e1 Standard Test Method for Determination of N-Methyl-Carbamoyloximes and N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post-Column Derivatization.pdf》由会员分享,可在线阅读,更多相关《ASTM D5315-04(2017)e1 Standard Test Method for Determination of N-Methyl-Carbamoyloximes and N-Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post-Column Derivatization.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5315 04 (Reapproved 2017)1Standard Test Method forDetermination of N-Methyl-Carbamoyloximes andN-Methylcarbamates in Water by Direct Aqueous InjectionHPLC with Post-Column Derivatization1This standard is issued under the fixed designation D5315; the number immediately following the des
2、ignation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEWarning notes were editorially updat
3、ed throughout in December 2017.1. Scope1.1 This is a high-performance liquid chromatographic(HPLC) test method applicable to the determination of certainn-methylcarbamoyloximes and n-methylcarbamates in groundwater and finished drinking water (1).2This test method isapplicable to any carbamate analy
4、te that can be hydrolyzed toa primary amine. The following compounds have been vali-dated using this test method:AnalyteChemical Abstract ServicesRegistry NumberAAldicarb 116-06-3Aldicarb sulfone 1646-88-4Aldicarb sulfoxide 1646-87-3Baygon 114-26-1Carbaryl 63-25-2Carbofuran 1563-66-23-Hydroxycarbofu
5、ran 16655-82-6Methiocarb 2032-65-7Methomyl 16752-77-5Oxamyl 23135-22-0ANumbering system of Chemical Abstracts, Inc.1.2 This test method has been validated in a collaborativeround-robin study (2) and estimated detection limits (EDLs)have been determined for the analytes listed in 1.1 (Table 1).Observ
6、ed detection limits may vary between ground waters,depending on the nature of interferences in the sample matrixand the specific instrumentation used.1.3 This test method is restricted to use by, or under thesupervision of, analysts experienced in both the use of liquidchromatography and the interpr
7、etation of liquid chromato-grams. Each analyst should demonstrate an ability to generateacceptable results with this test method using the proceduredescribed in 12.3.1.4 When this test method is used to analyze unfamiliarsamples for any or all of the analytes listed in 1.1, analyteidentifications sh
8、ould be confirmed by at least one additionalqualitative technique.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It i
9、s theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Additional guidance on laboratory safety is available andsuitable references for the information are provided
10、 (3-5).1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarr
11、iers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3D1129 Terminology Relating to WaterD1192 Guide for Equipment for Sampling Water and Steamin Closed Conduits (Withdrawn 2003)4D1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicab
12、le Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic Constituents1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility o
13、f Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved Dec. 15, 2017. Published January 2018. Originallyapproved in 1992. Last previous edition approved in 2011 as D5315 04 (2011).DOI: 10.1520/D5315-04R17E01.2The boldface numbers in parentheses refer to
14、the references at the end of thistest method.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approv
15、ed version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization e
16、stablished in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1E682 Practice for Liquid Chromatography Terms and Rela-tionships2.2 U.S. Environmental Protection Age
17、ncy Standard:5EPAMethod 531.1 Revision 3.0, USEPA, EMSL-Cincinnati,1989EPAMethod 531.2 Revision 1.0, USEPA, EMSL-Cincinnati,20013. Terminology3.1 Definitions:3.1.1 For definitions of water terms used in this standard,refer to Terminology D1129.3.1.2 For definitions of other terms used in this standa
18、rd,refer to Practice E682.3.2 Definitions of Terms Specific to This Standard:3.2.1 calibration standard (CAL),na solution preparedfrom the primary dilution standard solution and stock standardsolutions of the internal standards and surrogate analytes. CALsolutions are used to calibrate the instrumen
19、t response withrespect to analyte concentration.3.2.2 field duplicates (FD1 and FD2),ntwo separatesamples collected at the same time, placed under identicalcircumstances, and treated exactly the same throughout fieldand laboratory procedures. Analyses of FD1 and FD2 providea measure of the precision
20、 associated with sample collection,preservation, and storage, as well as with laboratory proce-dures.3.2.3 field reagent blank (FRB),nreagent water placed ina sample container in the laboratory and treated in all respectsas a sample, including being exposed to sampling siteconditions, storage, prese
21、rvation, and all analytical procedures.The purpose of the FRB is to determine whether methodanalytes or other interferences are present in the field environ-ment.3.2.4 internal standard, na pure analyte(s) added to asolution in known amount(s) and used to measure the relativeresponses of other analy
22、tes and surrogates that are componentsof the same solution. The internal standard must be an analytethat is not a sample component.3.2.5 laboratory duplicates (LD1 and LD2),ntwo samplealiquots taken in the analytical laboratory and analyzed sepa-rately with identical procedures. Analyses of LD1 and
23、LD2provide a measure of the precision associated with laboratoryprocedures, but not with sample collection, preservation, orstorage procedures.3.2.6 laboratory-fortified blank (LFB),nan aliquot ofreagent water to which known quantities of the test methodanalytes are added in the laboratory. The LFB
24、is analyzedexactly as a sample is; its purpose is to determine whether themethodology is in control and whether the laboratory iscapable of making accurate and precise methods at the requiredtest method detection limit.3.2.7 laboratory-fortified sample matrix (LFM),nan ali-quot of an environmental s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D5315 04 2017 e1 Standard Test Method for Determination of Methyl Carbamoyloximes and Methylcarbamates in Water by Direct Aqueous Injection HPLC with Post Column Derivatization

链接地址:http://www.mydoc123.com/p-286905.html