《HD 384 5 52 S1 A1-1998 AMD 1 Electrical Installations of Buildings Part 5 Selection and Erection of Electrical Equipment Chapter 52 Wiring Systems (Incorporatin.pdf》由会员分享,可在线阅读,更多相关《HD 384 5 52 S1 A1-1998 AMD 1 Electrical Installations of Buildings Part 5 Selection and Erection of Electrical Equipment Chapter 52 Wiring Systems (Incorporatin.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、HARMONIZATION DOCUMENT HD 384.5.52 WAI DO CU M ENT D HARM O N I SAT1 ON HARMONISIERUNGSDOKUMENT May 1998 ICs 29.060.20: 91.140.50 Descriptors: Electrical installation, building, wiring system, type, selection, currentcarrying capacity, section, voitage drop English version Electrical installations o
2、f buildings Part 5: Selection and erection of electrical equipment Chapter 52: Wiring systems Installations lectriques des btiments Partie 5: Choix et mise en oeuvre des matriels lectriques Chapitre 52: Canalisations Elektrische Anlagen von Gebuden Teil 5: Auswahl und Errichtung von elektrischen Bet
3、riebsmitteln Kapitel 52: Kabel- und Leitungssysteme (-anlagen) This amendment Al modifies the Harmonization Document HD 384.5.52 S1:1995; it was approved by CENELEC on 1998-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for impleme
4、ntation of this amendment on a nationai level. Up-to-date lists and bibliographical references concerning such national implementation may be obtained on application to the Central Secretariat or to any CENELEC member. This amendment exists in three official versions IEnglish, French, Gemanl, CENELE
5、C members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. I OFFICrALCOPY I CENELEC European Committee for El
6、ectrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 1998 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Re
7、f. No. HO 384.5.52 S1:1995/Al:1998 E Page 2 HD 384.5.52 S2:1995/A1:1998 Foreword This amendment was prepared by SC 64B, Protection against thermal effects, of Technical Committee CENELEC TC 64, Electrical installations of buildings. The text of the draft amendment, prAA, was submitted to the Unique
8、Acceptance Procedure and was approved by CENELEC as amendment Al to HD 384.5.52 S1:1995 on 1998-04-01. The following dates were fixed: - latest date by which the existence of the amendment has to be announced at national level - latest date by which the amendment has to be implemented at national le
9、vel by publication of a harmonized national standard or by endorsement - latest date by which the national standards conflicting with the amendment have to be withdrawn (doa) 1998-06-01 (dop) 1998-1 2-01 (daw) 1998-1 2-83 Replace the text of sub-clause 528.1.1 by the following: 528.1.1 Band I and ba
10、nd II voltage circuits shall not be contained in the same wiring system unless one of the following methods is adopted: - every cable is insulated for the highest voltage present; or - each conductor of a multiple core cable is insulated for the highest voltage present in the cable; or - the cables
11、are insulated for their system voltage and installed in a separate compartment of a cable ducting or cable trunking system; or - the cables are installed on a tray where physical separation is provided by a partition; or - a separate conduit, trunking, or ducting system is employed. NOTE: Special co
12、nsideration of electrical interference, both electromagnetic and electrostatic may apply to telecommunication circuits, data transfer circuits and the like. STD-CENELEC tiD 384.5-52 SL/AL-ENGL 1778 3404583 DLBb2bL 45b m CENELEC Corrigendum to HD 384.5.52 S1:1995/A1:1998 English version Add before th
13、e note: For SELV and PELV systems, the requirements of 41 1 .1.3.2 shall be fulfilled. September 1998 Page 3 HO 384.5.52 S1 :I995 accessible 25 21, 25 22 31, 32, Building 75 voids not accessible 21, 25, O 22 O 73,74 73, 74 Endorsement notice 23 12, 13, O 14, 15.16 23 O The text of the International
14、Standard IEC 384-5-52:1993 was approved by CENELEC as a Harmonization Document with agreed common modifications as given below. COMMON MODIFICATIONS 520.2 521.2 521.5 Table 52F Table 52G Normative references Replace the text of this subclause by : NOTE : Normative references to international publica
15、tions are listed in annex u (normative). Add the following note : NOTE : Other methods of installation of wiring systems not included in table 52 G are allowed provided that they fulfil the requirements of this chapter. AC circuits Change the beginning of this subclause to : Conductors and single co
16、re cables of a.c. circuits . Column cable trunking/line insulated conductors add an asterisk (*) and add at the bottom of the table the following. (*) insulated conductors are admitted if the cover can be only taken off by the mean of a tod or with an imponani hand exertion and i the trunking is IP4
17、X or IPXXD. Replace the first line of the table by the following Table 52G Table 52H Table 52H Table 52H Column cable trunking/line embedded in structure : add 75 Reference 13 - Read : On perforated trays or on wire mesh - run horizontally or vertically. Reference 31.31A - add : Insulated conductors
18、 Reference 41 - read : Insulated conductors, single and/or multicore cables in conduits in enclosed cable channels, run horizontally or vertically. I Page 4 I HD 384.5.52 S1:1995 1 Table S2H Reference 42 and 43 - add at the end of the description : (1 1 and at the bottom of the page add : (i) It is
19、recommended that these methods of installation are used only ln areas where access is restricted to authoiied persons and the reduction of current-caMng capacity and the fire hazard due to the accumulation of debris can be prevented Table 52H Reference 72 - Read : insulated conductors, sheathed sing
20、lecore or multicore cables in skirting, tninking space for data and communication cables. Table 52H Add the following reference insulated conductors or singlecore or rnulticore cables in embedded trunking 35 522.1.1 522.1.3 522.1.3 522.2.1 522.6.1 522.8. i 522.1. 522.3, 522.3.3, 522.4, 522.4.2, 522.
21、5, 522.6, 522.6.2,522.7,522.7.1,522.8,522.9,522.9.1, 522.10, 522.10.1. 522.11. 522.11.1, 522.12, 522.12.2. 522.13,522.13.1, 522.14. 522.14.1, 522.14.2. Delete all Environnement Code references and references to Clauses of Section 321. Second line - Add after the highest : or the iowest Add the new f
22、ollowing paragraph Where cables having different temperature ratings are installed in the same enclosure, the temperature rating of the cable system is taken to be the lowest temperature rating of all the cabies. Read : In order lo avoid the effects of heat from external sources, one or more of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD384552S1A11998AMD1ELECTRICALINSTALLATIONSOFBUILDINGSPART5SELECTIONANDERECTIONOFELECTRICALEQUIPMENTCHAPTER52WIRINGSYSTEMSINCORPORATINPDF

链接地址:http://www.mydoc123.com/p-1341089.html