ISO 6182-2-2012 Fire protection - Automatic sprinkler systems - Part 2 Requirements and test methods for wet alarm valves retard chambers and water motor alarms.pdf
《ISO 6182-2-2012 Fire protection - Automatic sprinkler systems - Part 2 Requirements and test methods for wet alarm valves retard chambers and water motor alarms.pdf》由会员分享,可在线阅读,更多相关《ISO 6182-2-2012 Fire protection - Automatic sprinkler systems - Part 2 Requirements and test methods for wet alarm valves retard chambers and water motor alarms.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 ISO 2012 Fire protection Automatic sprinkler systems Part 2: Requirements and test methods for wet alarm valves, retard chambers and water motor alarms Protection contre lincendie Systmes dextinction automatiques du type sprinkler Partie 2: Exigences et mthodes dessai des soupapes dalarme hydrauliq
2、ues, des limiteurs de surpression et des dispositifs dalarme moteur hydraulique INTERNATIONAL STANDARD ISO 6182-2 Third edition 2012-12-01 Reference number ISO 6182-2:2012(E) ISO 6182-2:2012(E)ii ISO 2012 All rights reserved COPYRIGHT PROTECTED DOCUMENT ISO 2012 All rights reserved. Unless otherwise
3、 specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright off
4、ice Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ISO 6182-2:2012(E) ISO 2012 All rights reserved iii Contents Page Foreword iv 1 Scope . 1 2 Normative references 1 3 T erms and definitions . 1 4 Requir
5、ements 3 4.1 Nominal sizes . 3 4.2 Connections . 3 4.3 Rated working pressure 3 4.4 Bodies and covers . 3 4.5 Strength (see 6.9) . 4 4.6 Access for maintenance . 4 4.7 Components . 4 4.8 Leakage (see 6.8) 5 4.9 Non-metallic components (excluding gaskets, seals and other elastomeric parts) (see 6.4 a
6、nd 6.5) 5 4.10 Sealing assembly elements (see 6.3) 5 4.11 Clearances . 5 4.12 Hydraulic friction loss (see 6.7) . 7 4.13 Endurance (see 6.6) 8 4.14 Operational performance (see 6.10) 8 4.15 Drains 9 4.16 Alarms (see 6.10.2) . 9 4.17 Retard device (see 6.12) . 9 4.18 Water motor alarms (see 6.11) 10
7、5 Production testing and quality control 11 6 Tests 12 6.1 Samples 12 6.2 Spring and diaphragm test 12 6.3 Sealing element tests (see 4.10) .12 6.4 Warm water aging test for non-metallic components (excluding gaskets and seals and other elastomeric parts) (see 4.9) .14 6.5 Air aging test for non-met
8、allic components (excluding gaskets and seals and other elastomeric parts) (see 4.9) 14 6.6 Endurance test (see 4.13) .15 6.7 Hydraulic friction loss test (see 4.12) 15 6.8 Valve leakage and deformation tests (see 4.8) .15 6.9 Body strength test (see 4.5) 16 6.10 Operational test (see 4.14) 16 6.11
9、Water motor alarm tests (see 4.16) .17 6.12 Retard chamber tests (see 4.17) .18 6.13 Salt mist corrosion test .18 7 Marking .18 8 Manufacturers installation instructions .19 Annex A (normative) Tolerances .20 ISO 6182-2:2012(E) Foreword ISO (the International Organization for Standardization) is a w
10、orldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented
11、on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafte
12、d in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Stand
13、ard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 6182-2 was prepared b
14、y Technical Committee ISO/TC 21, Equipment for fire protection and fire fighting, Subcommittee SC 5, Fixed firefighting systems using water. This third edition cancels and replaces the second edition (ISO 6182-2:2005), which has been technically revised. ISO 6182 consists of the following parts, und
15、er the general title Fire protection Automatic sprinkler systems: Part 1: Requirements and test methods for sprinklers Part 2: Requirements and test methods for wet alarm valves, retard chambers and water motor alarms Part 3: Requirements and test methods for dry pipe valves Part 4: Requirements and
16、 test methods for quick-opening devices Part 5: Requirements and test methods for deluge valves Part 6: Requirements and test methods for check valves Part 7: Requirements and test methods for early suppression fast response (ESFR) sprinklers Part 8: Requirements and test methods for pre-action dry
17、alarm valves Part 9: Requirements and test methods for water mist nozzles Part 10: Requirements and test methods for domestic sprinklers Part 11: Requirements and test methods for pipe hangers Part 12: Requirements and test methods for grooved-end components for steel pipe systemsiv ISO 2012 All rig
18、hts reserved INTERNATIONAL ST ANDARD ISO 6182-2:2012(E) Fire protection Automatic sprinkler systems Part 2: Requirements and test methods for wet alarm valves, retard chambers and water motor alarms 1 Scope This part of ISO 6182 specifies performance, requirements, methods of test and marking requir
19、ements, for wet alarm valves, retard chambers, water motor alarms and manufacturers specified relevant trim used in wet pipe automatic fire protection systems. This part of ISO 6182 is not applicable to performance and test requirements for other auxiliary components or attachments to alarm valves.
20、2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 898-1, Mechanical prop
21、erties of fasteners made of carbon steel and alloy steel Part 1: Bolts, screws and studs with specified property classes Coarse thread and fine pitch thread ISO 898-2, Mechanical properties of fasteners made of carbon steel and alloy steel Part 2: Nuts with specified property classes Coarse thread a
22、nd fine pitch thread 3 T erms an d definiti ons For the purposes of this document, the following terms and definitions apply. 3.1 alarm device mechanical or electrical device which sounds an alarm upon operation of the valve 3.2 clapper type of sealing assembly NOTE See also 3.13. 3.3 compensator ex
23、ternal or internal device such as an auxiliary valve that minimizes false alarms caused by a small increase of service pressure 3.4 corrosion-resistant material bronze, brass, Monel metal, austenitic stainless steel, or equivalent metallic or plastic material conforming with the requirements of this
24、 part of ISO 6182 NOTE Monel is an example of a suitable product available commercially. This information is given for the convenience of users of this part of ISO 6182 and does not constitute an endorsement by ISO of this product. ISO 2012 All rights reserved 1 ISO 6182-2:2012(E) 3.5 f low v el o c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO618222012FIREPROTECTIONAUTOMATICSPRINKLERSYSTEMSPART2REQUIREMENTSANDTESTMETHODSFORWETALARMVALVESRETARDCHAMBERSANDWATERMOTORALARMSPDF

链接地址:http://www.mydoc123.com/p-1254603.html