ASTM E966-2018a Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements.pdf
《ASTM E966-2018a Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements.pdf》由会员分享,可在线阅读,更多相关《ASTM E966-2018a Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E966 18E966 18aStandard Guide forField Measurements of Airborne Sound Attenuation ofBuilding Facades and Facade Elements1This standard is issued under the fixed designation E966; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis guide provides methods to measure the sound isolation of a room from outdoor sound, and toev
3、aluate the sound transmission or apparent sound transmission through a particular facade of theroom or an element of that faade such as a window or door. Measurements from outdoors to indoorsdiffer from measurements between two rooms. The outdoor sound field is not diffuse and thetransmission of tha
4、t sound through the structure is a function of the outdoor sound angle of incidence.The outdoor-indoor transmission loss values obtained with this guide are not expected to be the sameas that obtained in laboratory or other tests between two rooms using diffuse incident sound. At thistime, there are
5、 insufficient data available to specify a single, standard measurement procedure suitablefor all field situations. For this reason, this guide provides alternative test procedures for themeasurements of facade field level reduction and transmission loss.This guide is part of a set of standards for e
6、valuating the sound isolation of rooms and the soundinsulating properties of building elements. Others in this set cover the airborne sound transmission lossof an isolated partition element in a controlled laboratory environment (Test Method E90), thelaboratory measurement of impact sound transmissi
7、on through floors (Test Method E492), themeasurement of airborne sound transmission in buildings (Test Method E336), the measurement ofimpact sound transmission in buildings (Test Method E1007), the field measurement of airborne soundinsertion loss of doors (Test Method E2964), and the laboratory me
8、asurement of sound transmissionthrough a common plenum between two rooms (Test Method E1414).1. Scope1.1 This guide may be used to determine the outdoor-indoor noise reduction (OINR), which is the difference in sound pressurelevel between the free-field level outdoors in the absence of the structure
9、 and the resulting sound pressure level in a room. Eithera loudspeaker or existing traffic noise or aircraft noise can be used as the source. The outdoor sound field geometry must bedescribed and calculations must account for the way the outdoor level is measured. These results are used with Classif
10、icationE1332 to calculate the single number rating outdoor-indoor noise isolation class, OINIC. Both OINR and OINIC can vary withoutdoor sound incidence angle.1.2 Under controlled circumstances where a single faade is exposed to the outdoor sound, or a faade element such as a dooror window has much
11、lower transmission loss than the rest of the faade, an outdoor-indoor transmission loss, OITL(), or apparentoutdoor-indoor transmission loss,AOITL(), may be measured using a loudspeaker source.These results are a function of the angleof incidence of the sound field. By measuring with sound incident
12、at many angles, an approximation to the diffuse fieldtransmission loss as measured between two rooms can be obtained. The results may be used to predict interior sound levels ininstallations similar to that tested when exposed to an outdoor sound field similar to that used during the measurement. Th
13、e singlenumber ratings of apparent outdoor-indoor transmission class, AOITC(), using AOITL() and field outdoor-indoor transmissionclass, FOITC(), using OITL() may be calculated using Classification E1332. These ratings also may be calculated with the dataobtained from receiving room sound pressure m
14、easurements performed at several incidence angles as discussed in 8.6.1 This guide is under the jurisdiction ofASTM Committee E33 on Building and EnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.03 on SoundTransmission.Current edition approved Jan. 15, 2018Nov. 1, 2018. Pu
15、blished January 2018November 2018. Originally approved in 1984. Last previous edition approved in 20102018as E966 10E966 18.1. DOI: 10.1520/E0966-18.10.1520/E0966-18A.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have
16、 been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official docu
17、ment.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.3 To cope with the variety of outdoor incident sound field geometries that are encountered in the field, six testing techniquesare presented. These techniques and their general ap
18、plicability are summarized in Table 1 and Figs. 1-6. The room, faade, orfaade element declared to be under test is referred to as the specimen.1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes(excluding those in tables and figu
19、res) shall not be considered as requirements of the standard.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is
20、the responsibilityof the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability ofregulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standard
21、izationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and Environme
22、ntal AcousticsE90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and ElementsE336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in BuildingsE492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Fl
23、oor-Ceiling Assemblies Using theTapping MachineE1007 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-CeilingAssembliesand Associated Support StructuresE1332 Classification for Rating Outdoor-Indoor Sound AttenuationE1414 Test Method for Airborne Sound Att
24、enuation Between Rooms Sharing a Common Ceiling PlenumE2235 Test Method for Determination of Decay Rates for Use in Sound Insulation Test MethodsE2964 Test Method for Measurement of the Normalized Insertion Loss of Doors2.2 ANSI Standards:3S1.11 Specification for Octave-Band and Fractional-Octave An
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME9662018ASTANDARDGUIDEFORFIELDMEASUREMENTSOFAIRBORNESOUNDATTENUATIONOFBUILDINGFACADESANDFACADEELEMENTSPDF

链接地址:http://www.mydoc123.com/p-1243914.html