ASTM D5594-2018a Standard Test Method for Determination of the Vinyl Acetate Content of Ethylene-Vinyl Acetate (EVA) Copolymers by Fourier Transform Infrared Sp.pdf
《ASTM D5594-2018a Standard Test Method for Determination of the Vinyl Acetate Content of Ethylene-Vinyl Acetate (EVA) Copolymers by Fourier Transform Infrared Sp.pdf》由会员分享,可在线阅读,更多相关《ASTM D5594-2018a Standard Test Method for Determination of the Vinyl Acetate Content of Ethylene-Vinyl Acetate (EVA) Copolymers by Fourier Transform Infrared Sp.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5594 18aStandard Test Method forDetermination of the Vinyl Acetate Content of Ethylene-VinylAcetate (EVA) Copolymers by Fourier Transform InfraredSpectroscopy (FT-IR)1This standard is issued under the fixed designation D5594; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers infrared procedures for
3、deter-mining the vinyl acetate content of EVA copolymers usingpressed films (Procedure A) or molded plaques (Procedure B)and internal corrections for sample thickness.1.2 This test method is applicable to the analysis of EVAcopolymers containing 0.5 to 55 % vinyl acetate except asspecified in 1.3.1.
4、3 Talc interferes with the 1020 cm1vinyl acetate band.Resins containing 5 % vinyl acetate and talc are excludedfrom the scope of this test method.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forinformation purposes only.1.5 This st
5、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary s
6、tatements are given in Section 8.NOTE 1There is no known ISO equivalent to this standard.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards
7、, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E131 Terminology Relating to Molecular SpectroscopyE168 Practices for General Techniques of Infrared Quanti-tative AnalysisE177 Practice for Use
8、of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodIEEE/ASTM SI-10 Use of the International System of Units(SI): The Modem Metric SystemE691 Practice for Conducting an Interlaboratory Study toDetermine th
9、e Precision of a Test Method2.2 ISO Standard:ISO 8985 PlasticsEthylene/Vinyl Acetate CopolymerThermoplasticsDetermination of Vinyl Acetate33. Terminology3.1 Definitions:3.1.1 Units, symbols, and abbreviations used in this testmethod appear in Terminology E131 or IEEE/ASTM SI-10.3.2 Abbreviations:3.2
10、.1 EVAethylene-vinyl acetate copolymer.3.2.2 PTFEtetrafluorethylene polymer.3.2.3 FT-IRFourier transform infrared.4. Summary of Test Method4.1 The vinyl acetate content is measured using infraredabsorption band at 1020 cm1(0.5 to 5 % vinyl acetate) or 609cm1(5 to 55 % vinyl acetate).4.2 Sample thick
11、ness is measured internally using an ethyl-ene infrared absorption band at 720 cm1(28 to 55 % vinylacetate), 2020 cm1(0.5 to 28 % vinyl acetate), or 4250 cm1(5 to 28 % vinyl acetate).4.3 Regression analysis is performed on vinyl acetate/ethylene ratios versus known vinyl acetate contents for EVAcopo
12、lymer standards. The resulting equation is used to calcu-late the vinyl acetate content for subsequent EVA copolymersamples.1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approv
13、ed Nov. 1, 2018. Published November 2018. Originallyapproved in 1994. Last previous edition approved in 2018 as D5594 - 18. DOI:10.1520/D5594-18A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
14、 volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internat
15、ional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Gui
16、des and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15. Significance and Use5.1 Properties of EVA copolymers are affected by theamount of vinyl acetate incorporated in the copolymer: Thistest method provides a means to determine the vinyl acetat
17、elevel in copolymer samples.5.2 Before proceeding with this test method, referenceshould be made to the specification of the material being tested.Any test specimen preparation, conditioning, dimensions, ortesting parameters, or a combination thereof, covered in thematerials specification shall take
18、 precedence over those men-tioned in this test method. If there are no materialspecifications, then the default conditions apply.6. Apparatus6.1 Fourier Transform Infrared (FT-IR) Spectrophotometer,equipped with a detector, which gives a linear response overthe desired concentration range, is capabl
19、e of 4-cm2resolution(nominal), and is able to scan from 4400 to 450 cm1.NOTE 2ADTGS detector has been found suitable for this application.6.2 Hot Plate, (Sample Preparation Procedure A only).6.3 Microscope Slides, (Sample Preparation Procedure Aonly).6.4 Laboratory Press, capable of at least 9 000 k
20、g (20 000lb) 150C (300F), (Sample Preparation Procedure B only).6.5 Backing Plates, steel or aluminum (Sample PreparationProcedure B only).6.6 Brass Shim Stock (Roll), 50 to 150 m (2 to 6 mil) thickand 150 mm (6 in.) wide (Sample Preparation Procedure Bonly).6.7 Polyester Sheet, or fiberglass impreg
21、nated PTFE cloth(Sample Preparation Procedure B only).6.8 PTFE Film (Sample Preparation Procedure B, resinscontaining 40 % vinyl acetate only).6.9 Templates, (mold) with 150 150 mm (6 6 in.) piecesof paper or brass shim stock (item 6.6) containing cavities of asize and shape appropriate for the samp
22、le holders used, and, ifapplicable, sheets of items 6.7 and 6.8 (Sample PreparationProcedure B only).6.10 Cooling Block, steel or aluminum, at least 150 150mm (6 6 in.), approximately 25 mm (1 in.) thick, channeledfor cooling water (Sample Preparation Procedure B only).7. Materials7.1 EVA copolymer
23、standards containing nominal vinylacetate concentrations of 0.5 to 55 %, by weight.7.2 Dry ice (Sample Preparation B Procedure A only).8. Hazards8.1 Care shall be taken to avoid burns when handlingmicroscope slides on the hot-plate (Sample Preparation Proce-dure A), and gloves shall be worn when pla
24、ques are preparedusing a heated press (Sample Preparation Procedure B).8.2 Care also shall be taken to avoid breaking the micro-scope slides while removing the pressed polymer film.8.3 Care shall be taken to avoid burns when handling dryice.9. Specimen Preparation9.1 Procedure A:9.1.1 Control the ho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD55942018ASTANDARDTESTMETHODFORDETERMINATIONOFTHEVINYLACETATECONTENTOFETHYLENEVINYLACETATEEVACOPOLYMERSBYFOURIERTRANSFORMINFRAREDSPPDF

链接地址:http://www.mydoc123.com/p-1243654.html