1、Designation: C266 15C266 18Standard Test Method forTime of Setting of Hydraulic-Cement Paste by GillmoreNeedles1This standard is issued under the fixed designation C266; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the time of setting of hydraulic-cement paste by means of the Gillmore ne
3、edles.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to estab
4、lish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.Warning: Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolongedexposure.21.4 The text of this standard references notes and foo
5、tnotes which provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in
6、the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3C151C151/C151M Test Method for Autoclave Expansion of Hydraulic CementC18
7、3C183/C183M Practice for Sampling and the Amount of Testing of Hydraulic CementC187 Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement PasteC219 Terminology Relating to Hydraulic CementC305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plas
8、tic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and ConcretesC670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction MaterialsC1005 Specification for Reference Masses
9、and Devices for Determining Mass and Volume for Use in the Physical Testing ofHydraulic CementsD1193 Specification for Reagent Water3. Terminology3.1 Refer to Terminology C219 for definitions of terms.4. Summary of Test Method4.1 Sufficient water is added to the cement that is being tested to produc
10、e a paste of normal consistency. A specimen is moldedfrom this paste and is tested for time of setting by means of the Gillmore initial and final needles. The initial time of setting is thetime elapsed between initial contact of cement and water and the time when the Gillmore Initial needle does not
11、 leave a complete1 This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.30 on Time of SetCurrent edition approved Dec. 1, 2015Oct. 1, 2018. Published December 2015October 2018. Originally approved in 1951. Last previous editi
12、on approved in 20132015as C266 13.C266 15. DOI: 10.1520/C0266-15.10.1520/C0266-18.2 Section on Safety, Manual of Cement Testing, Annual Book of ASTM Standards, Vol 04.01.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annua
13、l Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be t
14、echnically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of t
15、his standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1circular impression in the paste surface. The final time of setting is the time elapsed between initial contact of cement and waterand the time when the Gillmore Final needle
16、 does not leave a complete circular impression in the paste surface.5. Significance and Use5.1 The purpose of this test method is to establish whether a cement complies with a specification limit on Gillmore time ofsetting.6. Apparatus6.1 Flat Trowel, having a sharpened straight-edged steel blade 10
17、0 to 150 mm in length. The edges when placed on a planesurface shall not depart from straightness by more than 1 mm.1 mm.6.2 Mixer, Bowl, Paddle, and Scraper, conforming to the requirements of Practice C305.6.3 Glass Graduates, 200 or 250 mL capacity, conforming to the requirements of Specification
18、C1005.6.4 Mass Determining Devices, conforming to the requirements of Specification C1005. The devices for determining mass shallbe evaluated for precision and accuracy at continuing precise performance utilizing the procedure in Specification C1005a totalload of 1000 g., Appendix X1, using a verifi
19、cation check mass of approximately 1000 g.6.5 Plane Non-absorptive Plates, 100 mm 6 5 mm square, of similar planeness, corrosivity, and absorptivity to that of glass(see Test Method C187 Fig. 1, item H).6.6 Gillmore Needles, conforming to the following requirements:6.6.1 The initial time of setting
20、needle shall have a mass of 113.4 6 0.5 g and a tip diameter of 2.12 6 0.05 mm.6.6.2 The final time of setting needle shall have a mass of 453.6 6 0.5 g and a tip diameter of 1.06 6 0.05 mm.6.6.3 The needle tips shall be cylindrical for a distance of 4.8 6 0.5 mm. The needle ends shall be plane and
21、at right anglesto the axis of the rod and shall be maintained in a clean condition (See Note 1).6.7 Inspect and document Section 6 apparatus for conformance to the requirements of this test method at least every 2 212years.years (see Note 2).NOTE 1The Gillmore needles should preferably be mounted as
22、 shown in Fig. 1 (b).NOTE 2Specification C1005 requires annual compliance checks for the reference masses and for the devices for determining mass.7. Reagents7.1 Mixing WaterPotable water is satisfactory for routine tests. For all referee and cooperative tests, reagent water conformingto the require
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC2662018STANDARDTESTMETHODFORTIMEOFSETTINGOFHYDRAULICCEMENTPASTEBYGILLMORENEEDLESPDF

链接地址:http://www.mydoc123.com/p-1243500.html