ASTM C177-2019 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus.pdf
《ASTM C177-2019 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus.pdf》由会员分享,可在线阅读,更多相关《ASTM C177-2019 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C177 19Standard Test Method forSteady-State Heat Flux Measurements and ThermalTransmission Properties by Means of the Guarded-Hot-PlateApparatus1This standard is issued under the fixed designation C177; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense
3、.1. Scope1.1 This test method establishes the criteria for the labora-tory measurement of the steady-state heat flux through flat,homogeneous specimen(s) when their surfaces are in contactwith solid, parallel boundaries held at constant temperaturesusing the guarded-hot-plate apparatus.1.2 The test
4、apparatus designed for this purpose is known asa guarded-hot-plate apparatus and is a primary (or absolute)method. This test method is comparable, but not identical, toISO 8302.1.3 This test method sets forth the general design require-ments necessary to construct and operate a satisfactoryguarded-h
5、ot-plate apparatus. It covers a wide variety of appa-ratus constructions, test conditions, and operating conditions.Detailed designs conforming to this test method are not givenbut must be developed within the constraints of the generalrequirements. Examples of analysis tools, concepts and proce-dur
6、es used in the design, construction, calibration and opera-tion of a guarded-hot-plate apparatus are given in Refs (1-41).21.4 This test method encompasses both the single-sided andthe double-sided modes of measurement. Both distributed andline source guarded heating plate designs are permitted. The
7、user should consult the standard practices on the single-sidedmode of operation, Practice C1044, and on the line sourceapparatus, Practice C1043, for further details on these heaterdesigns.1.5 The guarded-hot-plate apparatus can be operated witheither vertical or horizontal heat flow. The user is ca
8、utionedhowever, since the test results from the two orientations may bedifferent if convective heat flow occurs within the specimens.1.6 Although no definitive upper limit can be given for themagnitude of specimen conductance that is measurable on aguarded-hot-plate, for practical reasons the specim
9、en conduc-tance should be less than 16 W/(m2K).1.7 This test method is applicable to the measurement of awide variety of specimens, ranging from opaque solids toporous or transparent materials, and a wide range of environ-mental conditions including measurements conducted at ex-tremes of temperature
10、 and with various gases and pressures.1.8 Inhomogeneities normal to the heat flux direction, suchas layered structures, can be successfully evaluated using thistest method. However, testing specimens with inhomogeneitiesin the heat flux direction, such as an insulation system withthermal bridges, ca
11、n yield results that are location specific andshall not be attempted with this type of apparatus. See TestMethod C1363 for guidance in testing these systems.1.9 Calculations of thermal transmission properties basedupon measurements using this method shall be performed inconformance with Practice C10
12、45.1.10 In order to ensure the level of precision and accuracyexpected, persons applying this standard must possess aknowledge of the requirements of thermal measurements andtesting practice and of the practical application of heat transfertheory relating to thermal insulation materials and systems.
13、Detailed operating procedures, including design schematicsand electrical drawings, should be available for each apparatusto ensure that tests are in accordance with this test method. Inaddition, automated data collecting and handling systemsconnected to the apparatus must be verified as to theiraccu
14、racy. This can be done by calibration and inputting datasets, which have known results associated with them, intocomputer programs.1.11 It is not practical for a test method of this type toestablish details of design and construction and the proceduresto cover all contingencies that might offer diff
15、iculties to aperson without technical knowledge concerning theory of heatflow, temperature measurements and general testing practices.The user may also find it necessary, when repairing or1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsi
16、bility of Subcommittee C16.30 on ThermalMeasurement.Current edition approved Jan. 1, 2019. Published January 2019. Originallyapproved in 1942. Last previous edition approved in 2013 as C177 13. DOI:10.1520/C0177-19.2The boldface numbers given in parentheses refer to the list of references at theend
17、of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDev
18、elopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1modifying the apparatus, to become a designer or builder, orboth, on whom the demands for fundamental understandingand careful experimental technique ar
19、e even greater. Standard-ization of this test method is not intended to restrict in any waythe future development of new or improved apparatus orprocedures.1.12 This test method does not specify all details necessaryfor the operation of the apparatus. Decisions on sampling,specimen selection, precon
20、ditioning, specimen mounting andpositioning, the choice of test conditions, and the evaluation oftest data shall follow applicable ASTM Test Methods, Guides,Practices or Product Specifications or governmental regula-tions. If no applicable standard exists, sound engineeringjudgment that reflects acc
21、epted heat transfer principles must beused and documented.1.13 This test method allows a wide range of apparatusdesign and design accuracy to be used in order to satisfy therequirements of specific measurement problems. Compliancewith this test method requires a statement of the uncertainty ofeach r
22、eported variable in the report. A discussion of thesignificant error factors involved is included.1.14 Major sections within this test method are arranged asfollows:Section SectionScope 1Referenced Documents 2Terminology 3Summary of Test Method 4Significance and Use 5Apparatus 6Specimen Preparation
23、and Conditioning 7Procedure 8Calculation of Results 9Report 10Precision and Bias 11Keywords 12FiguresGeneral Arrangement of the Mechanical Components of the Guarded-Hot-Plate ApparatusFig. 1Illustration of Heat Flow in the Guarded-Hot-Plate Apparatus Fig.2Example Report Form Fig. 3AnnexesImportance
24、of Thickness A1.1Measuring Thickness A1.2Limitations Due to Apparatus A1.3Limitations Due to Temperature A1.4Limitations Due to Specimen A1.5Random and Systematic Error Components A1.6Error Components for Variables A1.7Thermal Conductance or Thermal Resistance Error Analysis A1.8Thermal Conductivity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1772019STANDARDTESTMETHODFORSTEADYSTATEHEATFLUXMEASUREMENTSANDTHERMALTRANSMISSIONPROPERTIESBYMEANSOFTHEGUARDEDHOTPLATEAPPARATUSPDF

链接地址:http://www.mydoc123.com/p-1243494.html