1、Designation: C1717 12C1717 18Standard Test Methods forConducting Strength Tests of Masonry Wall Panels1This standard is issued under the fixed designation C1717; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONEngineered design of masonry structures requires accurate technical data on the strength andload-deflection behavior of masonry
3、 wall elements. These test methods provide a systematic basis forobtaining such data.1. Scope*1.1 These test methods cover methods for determining the strength and load-deflection characteristics of masonry wall elements.1.2 The values stated in inch-pound units are to be regarded as standard. The v
4、alues given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to
5、 establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision o
6、n Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C1232 Terminology for MasonryE2126 Test Methods for Cyclic (Reversed) Load Test for She
7、ar Resistance of Vertical Elements of the Lateral Force ResistingSystems for Buildings3. Terminology3.1 DefinitionsTerminology defined in Terminology C1232 shall apply for this specification.4. Significance and Use4.1 The test methods described in this standard are intended for use as a starting poi
8、nt in developing specific testing protocolsfor masonry elements.4.1.1 The testing protocols could be used for general research on the load-deflection behavior of masonry elements.4.1.2 The testing protocols could be used for qualification of masonry elements and materials by evaluation services and
9、otherparties.4.1.3 The test methods described in this standard are general, and are intended to be adaptable to address a wide range ofanticipated support and loading conditions.4.2 How the test results are interpreted will depend on the intended use of the masonry element being tested.1 These test
10、methods are under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.04 onResearch.Current edition approved Dec. 1, 2012Dec. 15, 2018. Published December 2012January 2019. Originally approved in 2009. Last previous edition approv
11、ed in 20102012as C1717 010.C1717 12. DOI: 10.1520/C1717-12.10.1520/C1717-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on th
12、e ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users co
13、nsult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
14、n, PA 19428-2959. United States15. Test Specimens5.1 General DescriptionThe specimens shall have materials and workmanship representative of the structural elements theyare intended to represent, and be large enough to be useful in predicting the structural performance of those elements.5.2 Length o
15、r HeightThe specimen shall be long enough (for horizontal testing) or tall enough (for vertical testing) so thatits behavior under load will simulate that of the element that the specimen is intended to represent.5.3 WidthThe specimen shall be wide enough so that its behavior under load will simulat
16、e that of the element the specimenis intended to represent.5.4 Laboratory EnvironmentMaintain the air in the laboratory at a temperature of 75 6 15F (24 6 8C) and a relativehumidity of 55 6 25 %.5.5 Preconditioning of Masonry MaterialsPrecondition materials by storing in the laboratory environment f
17、or at least 5 daysbefore use.5.6 AgeTest masonry construction at an age of at least 28 days after fabrication, unless specified otherwise.6. General Requirements for Instrumentation6.1 Load MeasurementMeasure loads with a load cell or pressure transducer having a precision better than or equal to 1
18、%of the expected maximum load.6.2 Displacement MeasurementMeasure displacements with a linear potentiometer, linear variable displacement transformer(LVDT), or dial gauge having a precision equal to or better than the lesser of 61 % of the expected maximum displacement, or60.02 in. (60.5 mm).6.3 Dat
19、a AcquisitionRecord sufficient data to define the load-displacement curve with sufficient precision for the purposes ofthe test. Each set of data (load and displacement) is referred to as a “loading point.”7. General Requirements for Loading7.1 Loading MethodLoad specimens hydraulically using a hand
20、 pump, electrical pump, or air-driven pump.7.2 Test ControlControl the load manually or automatically (servo-controlled feedback system).7.2.1 Manual ControlIf the load is controlled manually, displacements are imposed on the specimen. The loading protocolmay be based on target loads or target displ
21、acements. It is generally convenient to use target loads until the load level approachesthe expected capacity, and then use target displacements.7.2.2 Automatic ControlIf the load is controlled automatically, either load or displacement is imposed on the system. Theloading protocol may be based on t
22、arget loads or target displacements. Use load control until the load level approaches the expectedcapacity, and then use displacement control.7.3 Loading ProtocolUse a loading protocol that is appropriate for the purposes of the test. The simplest loading protocol ismonotonic loading to failure.Amor
23、e complex loading protocol is cycles of loading (possibly reversed) to monotonically increasingmaximum amplitudes. Other protocols shall be permitted to be used.NOTE 1A wide range of loading protocols for in-plane tests is provided in Test Methods E2126.8. Axial Compression Test8.1 ApparatusUse a te
24、st setup incorporating the essential aspects of Fig. 1. Design the test setup to resist at least twice themaximum anticipated load. Design the test setup so its stiffness parallel to the axis of the specimen is at least 10 the anticipatedaxial stiffness of the specimen itself. The bottom of the spec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17172018STANDARDTESTMETHODSFORCONDUCTINGSTRENGTHTESTSOFMASONRYWALLPANELSPDF

链接地址:http://www.mydoc123.com/p-1243490.html