IEC 60353 AMD 1-2002 Line traps for a.c power systems Amendment 1《交流电力系统用线路阻波器.补充件1》.pdf
《IEC 60353 AMD 1-2002 Line traps for a.c power systems Amendment 1《交流电力系统用线路阻波器.补充件1》.pdf》由会员分享,可在线阅读,更多相关《IEC 60353 AMD 1-2002 Line traps for a.c power systems Amendment 1《交流电力系统用线路阻波器.补充件1》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、NORME INTERNATIONALE CEI IEC INTERNATIONAL STANDARD 60353 1989 AMENDEMENT 1 AMENDMENT 1 2002-04 Amendement 1 Circuits-bouchons pour rseaux alternatifs Amendment 1 Line traps for a.c. power systems Pour prix, voir catalogue en vigueur For price, see current catalogue IEC 2002 Droits de reproduction r
2、servs Copyright - all rights reserved International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch Commission Electrotechnique Internationale International Electrotec
3、hnical Commission L CODE PRIX PRICE CODE 2 60353 Amend. 1 CEI:2002 AVANT-PROPOS Le prsent amendement a t tabli par le comit dtudes 57 de la CEI: Conduite des systmes de puissance et communications associes. Le texte de cet amendement est issu des documents suivants: FDIS Rapport de vote 57/577/FDIS
4、57/584/RVD Le rapport de vote indiqu dans le tableau ci-dessus donne toute information sur le vote ayant abouti lapprobation de cet amendement. Le comit a dcid que le contenu de la publication de base et de ses amendements ne sera pas modifi avant 2005. A cette date, la publication sera reconduite;
5、supprime; remplace par une dition rvise, ou amende. _ INTRODUCTION Les circuits-bouchons se sont gnralement rvls tre des composants trs fiables dans les systmes dalimentation secteur. Certains problmes rencontrs sur le terrain avec des circuits-bouchons associs des dispositifs daccord ont toutefois
6、t signals au comit dtudes 57. Ces problmes sont rencontrs plus particulirement lorsque des sectionneurs se trouvent proximit des circuits-bouchons et quils sont frquemment manuvrs pour connecter ou dconnecter les lignes non charges. Il apparat que les surtensions transitoires provoques par la commut
7、ation du sectionneur peuvent tre dangereuses pour les condensateurs daccord des circuits-bouchons, et ce mme si les prescriptions thoriques mentionnes dans la CEI 60353 sont satisfaites. Les recherches et les essais mens au cours des dernires annes ont dmontr que la tension de claquage du matriau di
8、lectrique du condensateur dpend des proprits du matriau ainsi que de la nature et de la dure de la contrainte applique au dilectrique, par exemple forme du signal, impulsions unipolaires et bipolaires multiples. Cet amendement traite du problme des surtensions transitoires auxquelles sont exposs les
9、 circuits-bouchons, notamment celles provoques par le fonctionnement des sectionneurs. Laccent est mis sur les consquences sur la conception des dispositifs daccord. Les lments daccord autres que les condensateurs sont gnralement protgs par des clateurs, ce qui implique que les surtensions transitoi
10、res ne concernent que les condensateurs. Laptitude des condensateurs daccord rsister aux contraintes imposes par les oprations de commutation doit tre prouve par des essais de tenue en tension appropris. En consquence, il a t convenu que le titre et le domaine dapplication de cette annexe seraient:
11、Qualification dilectrique des condensateurs du dispositif daccord.60353 Amend. 1 IEC:2002 3 FOREWORD This amendment has been prepared by IEC technical committee 57: Power system control and associated communications. The text of this amendment is based on the following documents: FDIS Report on voti
12、ng 57/577/FDIS 57/584/RVD Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table. The committee has decided that the contents of the base publication and its amendments will remain unchanged until 2005. At this date, the pu
13、blication will be reconfirmed; withdrawn; replaced by a revised edition, or amended. _ INTRODUCTION In general, line traps have proven to be very reliable components of power line carrier systems. However, some line trap field problems associated with tuning devices were reported to technical commit
14、tee 57. This is particularly the case when disconnectors near to line traps are frequently operated to switch unloaded lines on or off. It appears that transient overvoltages created by disconnector switching may be hazardous to the tuning capacitors of line traps even if the design requirements doc
15、umented in IEC 60353 are fulfilled. Research in recent years based on testing, was carried out and showed that the breakdown strength of capacitor dielectric material is a function of the material properties and the nature and the duration of the applied dielectric stresses e.g. waveshapes, multiple
16、 unipolar and multiple bipolar impulses. This amendment will address the issue of the transient overvoltages seen by line traps, specifically those related to disconnector operations. Focus is on the consequences as related to the design of the tuning devices. The tuning elements, other than the cap
17、acitors, are usually protected by spark gaps and thus the transient overvoltages are critical for the capacitors only. The capability of the tuning capacitors to withstand the stresses imposed by switching operations should be proved by adequate voltage endurance tests. Therefore the title and the s
18、cope of this annex was agreed to be: Dielectric qualification of tuning device capacitors. 4 60353 Amend. 1 CEI:2002 Page 68 Ajouter, aprs lannexe B, la nouvelle annexe C suivante: Annexe C (normative) Qualification dilectrique des condensateurs du dispositif daccord C.1 Gnralits C.1.1 Domaine dappl
19、ication Les circuits-bouchons peuvent tre conus avec ou sans dispositif daccord. Une condition essentielle de lapplication des circuits-bouchons quips dun dispositif daccord est le haut niveau de fiabilit du dispositif daccord lorsquil est soumis aux contraintes dilectriques provoques par les coups
20、de foudre, les manuvres du coupe-circuit et les oprations de commutation du sectionneur. Lexigence fondamentale en matire de rsistance dilectrique du dispositif daccord est le niveau de protection apport par le parasurtenseur du circuit-bouchon. Les niveaux de tenue en tension des groupes de condens
21、ateurs du dispositif daccord doivent tre coordonns avec le niveau de protection du parasurtenseur pour les cas les plus dfavorables, aussi bien pour les impulsions de tension unipolaires (provoques par les coups de foudre) que pour les impulsions de tension rptitives bipolaires (provoques par les op
22、rations de commutation du sectionneur). Pour le parasurtenseur oxyde mtallique (MO) choisi, le niveau de protection est dfini par la tension rsiduelle U P1obtenue avec un courant transitoire de crte de 20 kA dans le parasurtenseur et un signal de 8/20 s. Dans cette annexe, les exigences dilectriques
23、 appliques au dispositif daccord se basent uniquement sur les parasurtenseurs MO sans clateur dont le niveau de protection est trs peu affect par la forme du signal. Dans le cas des circuits-bouchons protgs par des parasurtenseurs en srie avec des clateurs, il faut tenir compte du temps de retard de
24、 la tension de claquage provoqu par les clateurs. NOTE Le temps de retard de la tension de claquage des parasurtenseurs en srie avec des clateurs dpend de la vitesse de monte du front de limpulsion de tension. En consquence, le niveau de protection du systme est dtermin par la tension de claquage de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEC60353AMD12002LINETRAPSFORACPOWERSYSTEMSAMENDMENT1 交流 电力系统 线路 阻波器 补充 PDF

链接地址:http://www.mydoc123.com/p-1234392.html