1、09-11 07 12 00 - 1 SECTION 07 12 00 BUILT-UP BITUMINOUS WATERPROOFING SPEC WRITER NOTE: Delete any item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION: This section specifies impervious built-up membranes of bituminous materials used for wate
2、rproofing. 1.2 RELATED WORK: A. Reglets: Section 07 60 00, FLASHING AND SHEET METAL. B. Wood Nailers: Section 06 10 00, ROUGH CARPENTRY. C. Cement Topping: Section 03 30 00, CAST-IN-PLACE CONCRETE. 1.3 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLE
3、S. B. Manufacturers Literature and Data: Fiberboard, asphalt primer, felts and fabrics (each type to be used) C. Certificates: Indicating materials conform to contract specifications. 1.4 PRODUCT DELIVERY, STORAGE AND HANDLING: A. Deliver materials to job in manufacturers original unopened container
4、s with brand name marked thereon. B. Before proceeding with work, protect surfaces from excessive changes in temperature and protect piping, conduits and installed equipment and materials. 1.5 APPLICABLE PUBLICATIONS: A. The publications listed below form a part of this specification to the extent r
5、eferenced. The publications are referenced in text by basic designation only. B. American Society for Testing and Materials (ASTM): C208-08 Cellulosic Fiber Insulating Board D41-11 . Asphalt Primer Used in Roofing, Dampproofing, and Waterproofing D43-00(R2006) Coal Tar Primer used in Roofing, Damppr
6、oofing, and Waterproofing D173-03 Bitumen-Saturated Cotton Fabrics used in Roofing and Waterproofing D226-09 Asphalt-Saturated Organic Roofing Felt Used in Roofing and Waterproofing Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 07 12 00 - 2 D
7、227-03 Coal-Tar-Saturated Organic Roofing Felt Used in Roofing and Waterproofing D449-03(R2009) . Asphalt Used in Dampproofing and Waterproofing D450-07 Coal Tar Pitch Used in Roofing, Dampproofing, and Waterproofing D1327-04 . Bitumen-Saturated Woven Burlap Fabrics Used in Roofing and Waterproofing
8、 D1668-97(R2006) Glass Fabrics (Woven and Treated) for Roofing and Waterproofing D2178-04 . Asphalt Glass Felt Used in Roofing and Waterproofing D4022-07 . Coal Tar Roof Cement D4586-07 . Asphalt Roof Cement, Asbestos-Free PART 2 PRODUCTS: SPEC WRITER NOTE: Make material requirements agree with appl
9、icable requirements specified in the referenced Applicable Publications. Update and specify only that applies to the project. 2.1 BITUMEN: A. Asphalt: ASTM D449, Type I, for exterior work below grade, Type III for work above grade, where asphalt will be exposed to sunlight. B. Coal-Tar: ASTM D450, T
10、ype II. SPEC WRITER NOTE: In cases where waterproofing must be applied to concrete or masonry walls in waterlogged soils or where some settlement is likely to occur, it may be advisable to use the fabric type instead of the felt type. In cases where rough masonry walls must be waterproofed, unless s
11、uch walls can be made reasonably smooth with a parging of cement mortar, specify only the fabric type of membrane waterproofing. 2.2 FELTS AND FABRICS (FOR USE WITH ASPHALT): A. Cotton Fabric Asphalt-Saturated: ASTM D173. B. Organic Felt Asphalt-Saturated: ASTM D226, Type I. C. Glass Mat (Fabric) As
12、phalt-impregnated: ASTM D2178, Type IV. 2.3 FELTS AND FABRICS (FOR USE WITH COAL-TAR): A. Cotton Fabric Coal-Tar Saturated: ASTM D173. B. Organic Felt Coal-Tar Saturated: ASTM D227. C. Burlap (Fabric) Coal-Tar Saturated: ASTM D1327. D. Glass Fabric, Coal-Tar Treated: ASTM D1668. Provided by IHSNot f
13、or ResaleNo reproduction or networking permitted without license from IHS-,-,-09-11 07 12 00 - 3 2.4 PRIMER: A. Use ASTM D41 for asphalt products. B. Use ASTM D43 for coal-tar products. 2.5 FIBERBOARD: ASTM C208, Type V, Class C, 13 mm (1/2-inch) thick. 2.6 CEMENT: A. ASTM D4022 with coal tar produc
14、ts. B. ASTM D4586 with asphalt products. PART 3 EXECUTION: SPEC WRITER NOTE: Check Concrete and Masonry sections to insure that surfaces to receive waterproofing are moist-cured. Application of any coatings may reduce the bonding of waterproofing to concrete or masonry. 3.1 PREPARATION: A. Do not ap
15、ply waterproofing when ambient temperature is 4.4oC (40oF) or lower. B. Cleaning and Filling: 1. Before applying waterproofing materials, clean surfaces smooth, firm and dry. 2. Remove high spots, depressions, loose and foreign particles; and fill all voids, joints and cracks with Portland cement mo
16、rtar. 3. Surface shall be approved by Resident Engineer before waterproofing is started. 3.2 GENERAL: A. Ventilation: Provide adequate ventilation for waterproofing installed in enclosed spaces. B. Compatibility of Materials: Use coal-tar pitch with coal-tar-saturated felts and fabric. Use asphalt w
17、ith asphalt-saturated felts and fabrics. C. Temperature of Bitumen: Heat bitumen to flow freely when applied, but not above 190oC (375oF) for coal-tar, and not above 230oC (450oF) for asphalt. D. Rate of Application: Apply primers at the rate of 0.4 L/m2 (one gallon per 100 square feet) over concret
18、e and parging. Apply coal-tar at the rate of 1.9 kg/m2 (40 pounds per 100 square feet) and asphalt at the rate of 1.5 kg/m2 (30 pounds per 100 square feet), for each mopping. E. Number of Plies: 1. Membrane waterproofing shall consist of four plies of felt or fabric. Provided by IHSNot for ResaleNo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0712002011BUILTUPBITUMINOUSWATERPROOFINGPDF

链接地址:http://www.mydoc123.com/p-1074703.html