1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULApril 15, 20051SUBJECT 2506OUTLINE OF INVESTIGATIONFORRefractory Panels For Masonry FireplacesIssue No: 1April 15, 2005Summary of TopicsThis is the first issue of the Outline of Investigation for
2、 Refractory PanelsFor Masonry Fireplaces, Subject 2506, which covers refractory panelsused within the firebox of masonry fireplaces to replace existing panels,to reduce the firebox size or to allow for reduced clearance tocombustible construction.COPYRIGHT 2005 UNDERWRITERS LABORATORIES INC.UL COPYR
3、IGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPRIL 15, 2005SUBJECT 25062No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units
4、 of Measurement .44 Undated References 55 Glossary .5CONSTRUCTION6 Materials .5PERFORMANCE7 General 58 Test Installation .69 Temperature Measurement .710 Brand Fire Test 711 Flash Fire Test 712 Fire Chamber Strength Test .7MARKING13 General .7INSTALLATION AND MAINTENANCE INSTRUCTIONS14 General .815
5、Installation Instructions .816 Maintenance Instructions .9APRIL 15, 2005 SUBJECT 2506 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover refractory panels used within the firebox of masonry firepla
6、ces to replaceexisting panels, to reduce the firebox size or to allow for reduced clearance to combustible construction.1.2 The panels shall be installed within masonry fireplaces which are constructed in accordance with theStandard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances,
7、 NFPA 211 and theInternational Residential Code, IRC.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shall comply with therequirements for that component.2.2 A component need not comply with a specific requirement that:a) Involves a feature or characteris
8、tic not needed in the application of the component in thevalue covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction
9、 features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are t
10、he requirement. Values in parentheses are explanatory orapproximate information.APRIL 15, 2005SUBJECT 25064UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to code or standard appearing in the requi
11、rements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purpose of this Outline, the following definitions apply.5.2 CERTIFIED CHIMNEY SWEEP A chimney sweep certified by a nationally endorsed chimneysweep organization.5.3 MASONRY
12、CHIMNEY A field constructed chimney of solid masonry units, bricks, stones, orreinforced - portland-cement concrete, which may or may not be lined with chimney flue liners built inaccordance with applicable building code requirements.5.4 MASONRY FIREPLACE A field-constructed assembly constructed in
13、accordance with theStandard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, NFPA 211, and inaccordance with codes such as the International Residential Code and the Uniform Mechanical Code.5.5 QUALIFIED PERSON A trained installer who has successfully completed a thorough, company
14、-sponsored training course and who is familiar with the use of the product and the risks associated withimproper installation procedures.5.6 REFRACTORY PANEL A noncombustible material used in the construction of the fireplace to linethe firebox.CONSTRUCTION6 Materials6.1 Parts used as refractory pan
15、els shall be of noncombustible material.PERFORMANCE7 General7.1 After being subjected to the tests specified in Sections 10 12, as applicable, the refractory panelsshall be capable of being further used. The panels shall be free of cracks, distortion, or other damage.The panels are to be visually in
16、spected to determine that damage has not occurred.7.2 Test results indicating compliance with the requirements in 7.1 include the following:a) No part of the product has become damaged or permanently distorted to an extent that thepanel will not continue to function as intended; andb) A refractory p
17、anel material has not cracked in a manner allowing portions of the panel tobecome dislodged by poking the panel with a sharp instrument.APRIL 15, 2005 SUBJECT 2506 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.3 A refractory panel shall c
18、omply with the following:a) The thermal conductivity of the refractory panel shall not be increased; andb) The refractory panel material shall not show evidence of softening, melting, disintegrating,losing binder, or other malfunction or deterioration.8 Test Installation8.1 The following factors are
19、 to form the basis of the performance tests of a product:a) Size and type of refractory panel;b) Type of panel construction and material; andc) Samples of refractory panels shall be representative of the material manufacturers curingand mixing specifications and thickness.8.2 Refractory panels are t
20、o be tested with representative samples of the materials used in production.For these purposes, the particle size, densities, mixing proportions of the ingredients, and chemical andphysical properties of the ingredients are to be verified prior to installation of the refractory panels into thefirepl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT25062005OUTLINEOFINVESTIGATIONFORREFRACTORYPANELSFORMASONRYFIREPLACESISSUE1 体壁 耐火 调查 纲要 版本号

链接地址:http://www.mydoc123.com/p-1069295.html