《UL SUBJECT 2505-2005 OUTLINE OF INVESTIGATION FOR CEMENTITIOUS MATERIALS USED FOR RESURFACING SMOKE CHAMBER OF MASONRY FIREPLACES (Issue 1)《砖石结构壁炉的面层重做用胶结材料调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2505-2005 OUTLINE OF INVESTIGATION FOR CEMENTITIOUS MATERIALS USED FOR RESURFACING SMOKE CHAMBER OF MASONRY FIREPLACES (Issue 1)《砖石结构壁炉的面层重做用胶结材料调查大纲 发布编号 1》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULApril 8, 20051SUBJECT 2505OUTLINE OF INVESTIGATIONFORCEMENTITIOUS MATERIALS USED FOR RESURFACING SMOKE CHAMBEROF MASONRY FIREPLACESIssue No: 1APRIL 8, 2005Summary of TopicsThis is the first issue
2、 of the Outline of Investigation for CementitiousMaterials Used For Resurfacing Smoke Chamber of Masonry Fireplaces,Subject 2505.COPYRIGHT 2005 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPRIL 8, 2005SUBJECT
3、25052No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units of Measurement .44 Undated References 55 Glossary .5CONSTRUCTION6 Materials .6PERFORMANCE7 General 68 Test Installatio
4、n .79 Temperature Measurement .810 Brand Fire Test 811 Flash Fire Test 8MATERIAL TESTS12 General .813 Resistance to Action of Acids Test for Nonmetallic Flue-Gas Conduit 814 Freezing and Thawing Test for Water Absorptive Nonmetallic Materials 8MARKING15 General .9INSTALLATION AND MAINTENANCE INSTRUC
5、TIONS16 General .917 Installation Instructions 1018 Maintenance Instructions 11APRIL 8, 2005 SUBJECT 2505 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover cementitious materials used for resurfac
6、ing smoke chambers of new orexisting masonry fireplaces. These products are intended for field application.1.2 Cementitious resurfacing materials are intended to be installed within the smoke chamber of masonryfireplaces that have been constructed in accordance with the Standard for Chimneys, Firepl
7、aces, Vents,and Solid Fuel-Burning Appliances, NFPA 211.1.3 Cementitious resurfacing materials are not intended to provide structural support for the masonryfireplace chimney.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shall comply with therequirement
8、s for that component.2.2 A component need not comply with a specific requirement that:a) Involves a feature or characteristic not needed in the application of the component in thevalue covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accor
9、dance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits
10、, and shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.APRIL 8, 2005SUBJECT 25054UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRI
11、BUTION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purpose of this Outline, the following definitions ap
12、ply.5.2 CEMENTITIOUS MATERIAL RESURFACING SYSTEM A nonmetallic material that is factorymade or mixed, and that is assembled in the field to restore the ability of a smoke chamber to containand convey the products of combustion to the outside and to allow for reduced clearance tocombustible construct
13、ion.5.3 CERTIFIED CHIMNEY SWEEP A chimney sweep certified by a nationally endorsed chimneysweep organization.5.4 FIREPLACE DAMPER A plate located at the top of a masonry fireplace, used to stop the flow ofair or restrict the flow of flue-gas air mixtures from inside the fireplace to the outdoors.5.5
14、 HEATING APPLIANCE A chimney-connected, fuel-burning device.5.6 MASONRY CHIMNEY A field constructed chimney of solid masonry units, bricks, stones, orreinforced portland-cement concrete, which may or may not be lined with chimney flue liners built inaccordance with applicable building code requireme
15、nts.5.7 MASONRY FIREPLACE A field-constructed assembly constructed in accordance with theStandard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, NFPA 211, and inaccordance with the International Residential Code, IRC.5.8 QUALIFIED PERSON A trained installer who has successfully
16、completed a thorough, company-sponsored training course and who is familiar with the use of the product and the risks associated withimproper installation procedures.5.9 SMOKE CHAMBER The transitional area from the damper opening to the beginning of the flueliner of the fireplace system.APRIL 8, 200
17、5 SUBJECT 2505 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONSTRUCTION6 Materials6.1 Parts used in a cementitious material for resurfacing smoke chamber shall be of noncombustible,corrosion-resistant materials.6.2 Cementitious resurface
18、materials shall comply with the requirements in Section 13, Resistance toAction of Acids Tests for Nonmetallic Flue-Gas Conduit; and Section 14, Freezing and Thawing Test ofWater Absorptive Nonmetallic Materials; as applicable.6.3 Paint coatings shall remain intact at the maximum temperatures obtain
19、ed on the part during the testsspecified in these requirements.6.4 Except for binder materials, cementitious resurfacing materials shall be noncombustible.6.5 Cementitious resurfacing materials that are self-supporting shall be applied to solid surfaces so thatthe material does not sag. An adhesive
20、or cement that is depended upon to adhere the material tomasonry brick/clay tile shall retain its adhesive qualities at any temperature the adhesive is capable ofattaining when tested in accordance with these requirements and at 0F (minus 18C).6.6 A water-absorbing cementitious resurfacing material
21、shall not be subject to wetting by condensationor rain when installed as intended.PERFORMANCE7 General7.1 After being subjected to the Brand Fire Test, Section 10, and the Flash Fire Test, Section 11, thecementitious resurfacing material shall be capable of being further used. The cementitious resur
22、facingmaterial shall be free of cracks, distortion, or other damage. The cementitious resurfacing material is tobe visually inspected (including the use of a video camera, if necessary) to determine that damage hasnot occurred.7.2 Test results indicating compliance include the following:a) No part o
23、f the product has become damaged or permanently distorted to an extent that it orthe smoke chamber of the masonry fireplace will not continue to function as intended; andb) A cementitious resurfacing material has not cracked in a manner allowing portions of theliner to become dislodged by poking the
24、 smoke chamber surface with a sharp instrument.7.3 A cementitious resurfacing system shall comply with the following:a) Cementitious resurfacing material shall remain in its intended position prior to, during, andfollowing tests on the fireplace system;b) Products resulting from the loosening, combu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT25052005OUTLINEOFINVESTIGATIONFORCEMENTITIOUSMATERIALSUSEDFORRESURFACINGSMOKECHAMBEROFMASONRYFIREPLACESISSUE1

链接地址:http://www.mydoc123.com/p-1069294.html