UL 60730-1 (ND)-2009 National Differences For UL 60730-1 Automatic Electrical Controls for Household and Similar Use - Part 1 General Requirements (Fourth Edition Reprint with Revi.pdf
《UL 60730-1 (ND)-2009 National Differences For UL 60730-1 Automatic Electrical Controls for Household and Similar Use - Part 1 General Requirements (Fourth Edition Reprint with Revi.pdf》由会员分享,可在线阅读,更多相关《UL 60730-1 (ND)-2009 National Differences For UL 60730-1 Automatic Electrical Controls for Household and Similar Use - Part 1 General Requirements (Fourth Edition Reprint with Revi.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-1Automatic Electrical Controls for Household and Similar Use - Part 1: General RequirementsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTR
2、IBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-1Automatic Electrical Controls for Household and Similar Use - Part 1: General RequirementsEdition: 4Edition Date: October 19, 2009These revisions are being issued to reflect the established effective date for UL 60730-1.AS OF OCTOBE
3、R 19, 2018, THE THIRD EDITION OF UL 60730-1A, THE TWELFTHEDITION OF UL 873, AND THE THIRD EDITION OF UL 244A, WILL BE WITHDRAWN ANDWILL BE REPLACED BY THIS STANDARD.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All ri
4、ghts reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, eithe
5、r expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages
6、arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of t
7、he claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is sto
8、ring an electronicStandard on the purchasers computer system.Copyright 2014 Underwriters Laboratories Inc.MAY 21, 2014NATIONAL DIFFERENCES FOR UL UL 60730-12UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single
9、 listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all typ
10、es of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe
11、acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are
12、 deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national
13、difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an enti
14、re numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or ann
15、ex of the base IEC text.MAY 21, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-1 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1.1DV.1 DE Modification of 1.1.1 by adding the following after the first paragraph:In IEC termin
16、ology, safety is defined as an acceptable level of risk. This is consistent withthe intention of UL requirements to reduce the risk of fire, shock or injury to persons.1.1.1DV.2 D2 Modification of the fourth paragraph of 1.1.1 by adding the following text:This standard also applies to automatic ELEC
17、TRICAL CONTROLS used in commercial andindustrial applications where no other standard currently covers the product or whenspecifically restricted within the scope of a relevant part 2 standard.1.2DV.1 DR Modification of 1.2 by adding the following text:The maximum voltage is 600 V. The maximum curre
18、nt is unlimited.1.5DV D2 Addition of the following to 1.5:The following UL Standards are referenced in this Standard:UL 20Switches, General Use SnapUL 44Wires and Cables, Thermoset-InsulatedUL 50Enclosures for Electrical Equipment, Non-Environmental ConsiderationsUL 50EEnclosures for Electrical Equi
19、pment, Environmental ConsiderationsUL 62Flexible Cords and CablesUL 83Wire and Cables, Thermoplastic-InsulatedUL 94Plastic Materials for Parts in Devices and Appliances, Tests for Flammability ofUL 157Gaskets and SealsUL 224Tubing, Extruded InsulatedMAY 21, 2014NATIONAL DIFFERENCES FOR UL UL 60730-1
20、4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL 248 seriesLow-Voltage FusesUL 310Terminals, Electrically Quick-ConnectUL 372Automatic Electrical Controls for Household and Similar Use Part 2: ParticularRequirements for Burner Ignition Syst
21、ems and ComponentsUL 429Valves, Electrically-OperatedUL 467Grounding and Bonding EquipmentUL 486 seriesWire ConnectorsUL 498Attachment Plugs and ReceptaclesUL 508Industrial Control EquipmentUL 510Tape, Polyethylene, and Rubber Insulating TapeUL 514AMetallic Outlet BoxesUL 514BFittings, Conduit, Tubi
22、ng and CableUL 514CNonmetallic Outlet Boxes, Flush-Device Boxes, and CoversUL 635Insulating BushingsUL 746APolymeric Materials Short Term Property EvaluationsUL 746BPolymeric Materials Long Term Property EvaluationsUL 746CPolymeric Materials Use in Electrical Equipment EvaluationsUL 746DPolymeric Ma
23、terials Fabricated PartsMAY 21, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-1 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL 796Printed-Wiring BoardsUL 810CapacitorsUL 817Cord Sets and Power-Supply CordsUL 863Time-Indicating and -Recording
24、ApplianceUL 917Switches, Clock OperatedUL 969Marking and Labeling SystemsUL 1004-1Rotating Electrical Machines General RequirementsUL 1054Switches, Special UseUL 1059Terminal BlocksUL 1077Protectors, Supplementary, for Use in Electrical EquipmentUL 1310Class 2 Power UnitsUL 1414Capacitors, and Suppr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL607301ND2009NATIONALDIFFERENCESFORUL607301AUTOMATICELECTRICALCONTROLSFORHOUSEHOLDANDSIMILARUSEPART1GENERALREQUIREMENTSFOURTHEDITIONREPRINTWITHREVIPDF

链接地址:http://www.mydoc123.com/p-1068440.html