《UL 2231-2 CRD-2014 UL Standard for Safety Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits Particular Requirements for Protection Devices for Use in Charging n.pdf》由会员分享,可在线阅读,更多相关《UL 2231-2 CRD-2014 UL Standard for Safety Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits Particular Requirements for Protection Devices for Use in Charging n.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): FFUQ2Standard Number: UL 2231-2Standard Title: Standard for Personnel Protection Systems for Electric Vehicle (EV)Supply Circuits: Particular Requirements fo
3、r Protection Devices for Use inCharging SystemsEdition Date: September 7, 2012Edition Number: 2Section / Paragraph Reference: Sections 14, 17, 18A, and Annex ASubject: Programmable ComponentsDECISION:14.3 A device with an automatic supervisory circuit shall be permitted to have an automatic reset fu
4、nctionwhich permits operation following an acceptable test. See 17.7 17.8.14.4 A device that has been evaluated to Annex A, Ref. No. 9, Annex A, Ref. No. 10, or both, shall bepermitted to have an automatic reset function when all of the following are met:a) There is shall be a minimum delay of 15 mi
5、nutes between the tripping function and thereset, andb) The device does shall not reset more than 4 times.c) A device having an automatic reset function utilizing solid state circuitry shall comply with therequirements in Annex A, Ref. No. 9.d) A device having an automatic reset function utilizing p
6、rogrammable components shallcomply with the requirements in 18A.1 - 18A.2.A manual intervention is able permitted to override the delay to the automatic reset. See 43.4.17.7 An automatic supervisory test system shall be subjected to analysis in accordance with: utilizing solidstate circuitry shall c
7、omply with the requirements in Annex A, Ref. No. 9.a) Annex A, Ref. No. 9,b) Annex A, Ref. No. 10, orc) Both (a) and (b), as appropriate.17.8 An automatic supervisory test system utilizing programmable components shall comply with therequirements in 18A.3 18A.4.18A Programmable Circuit ComponentsUL
8、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL18A.1 If a programmable circuit component such as a microprocessor is employed in a device with anautomatic reset function as mentioned in 14.4, the device shall be investigated in accordance with t
9、herequirements of Annex A, Ref. No. 10 as defined in 18A.2.18A.2 The risks to be considered in the investigation mentioned in 18A.1 shall include the followingscenarios as applicable:a) Failure to trip under conditions where tripping should occur;b) Tripping at the wrong trip threshold value;c) Fail
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL22312CRD2014ULSTANDARDFORSAFETYPERSONNELPROTECTIONSYSTEMSFORELECTRICVEHICLEEVSUPPLYCIRCUITSPARTICULARREQUIREMENTSFORPROTECTIONDEVICESFORUSEINCHARGINGNPDF

链接地址:http://www.mydoc123.com/p-1067865.html