UL 1637 CRD-2006 UL Standard for Safety Home Health Care Signaling Equipment - Section Paragraph Reference 36 2 (Edition 4 December 29 2006)《家庭保健信号设备的UL安全标准 节 段落参考 36 2 (第四版 2006年.pdf
《UL 1637 CRD-2006 UL Standard for Safety Home Health Care Signaling Equipment - Section Paragraph Reference 36 2 (Edition 4 December 29 2006)《家庭保健信号设备的UL安全标准 节 段落参考 36 2 (第四版 2006年.pdf》由会员分享,可在线阅读,更多相关《UL 1637 CRD-2006 UL Standard for Safety Home Health Care Signaling Equipment - Section Paragraph Reference 36 2 (Edition 4 December 29 2006)《家庭保健信号设备的UL安全标准 节 段落参考 36 2 (第四版 2006年.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories (UL). Itis normative for the applicable
2、UL Product Certification Program(s); however, it is currently not part ofthe UL Standard(s) referenced below.Product Category (CCN): MULQStandard Number: UL 1637Edition Date: December 29, 2006Edition Number: 4Section / Paragraph Reference: 36.2DECISION:Products utilizing other than a wall or ceiling
3、 type mounting configuration need to comply with the jarringrequirements delineated in 46.1 and 46.3. The jarring force for these types of mounted products shall beapplied directly to the product as described below.The product is to be mounted as intended. An impact of 4.08 J (3 ft-lb) is to be appl
4、ied directlyto any non-display area of the product by means of a 535 g (1.18 lb.), 51-mm (2 inch) diametersteel sphere swung through a pendulum arc from a height (h) of 775 mm (2.54 feet). Theat-rest suspension point of the steel sphere is to be 25.4 mm (1 inch) in front of the plane of theproduct t
5、o be impacted.Wall mounted products weighing more than 30 lbs. may be subjected to the direct impact method or themethod described in 46.2. The direct impact shall be applied to the center of the side of the productintended to be adjacent to the mounting surface during intended mounting.RATIONALE FO
6、R DECISION:The products investigated to this standard utilize a variety of mounting configurations. While the jarringrequirements apply to all products, the standard only describes a test method for wall and ceiling mountedproducts. The test method needs to include free standing and desktop mounted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1637CRD2006ULSTANDARDFORSAFETYHOMEHEALTHCARESIGNALINGEQUIPMENTSECTIONPARAGRAPHREFERENCE362EDITION4DECEMBER292006

链接地址:http://www.mydoc123.com/p-1067586.html