《UL 1618-2015 UL Standard for Safety Wall Protectors Floor Protectors and Hearth Extensions (Second Edition Reprint with Revisions Through and Including January 10 2018).pdf》由会员分享,可在线阅读,更多相关《UL 1618-2015 UL Standard for Safety Wall Protectors Floor Protectors and Hearth Extensions (Second Edition Reprint with Revisions Through and Including January 10 2018).pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1618 Wall Protectors, Floor Protectors, and Hearth ExtensionsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL
2、 NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Wall Protectors, Floor Protectors, and Hearth Extensions, UL 1618 Second Edition, Dated October 23, 2015 Summary of Topics This Second Edition of the Standard for Wall Protectors, Floor Pro
3、tectors, and Hearth Extensions, ANSI/UL 1618, has been issued as an Editorial New Edition update only. No changes to the requirements have been made. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic,
4、 mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable
5、 for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of su
6、ch damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, da
7、mage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. OCTOBER 23, 2015 UL 1618 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBU
8、TION WITHOUT PERMISSION FROM UL OCTOBER 23, 2015 UL 1618 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 23, 2015 1 UL 1618 Standard for Wall Protectors, Floor Protectors, and Hearth Extensions First Edition M
9、ay, 2009 Second Edition October 23, 2015 This ANSI/UL Standard for Safety consists of the Second Edition. The most recent designation of ANSI/UL 1618 as a Reaffirmed American National Standard (ANS) occurred on May 29, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal P
10、ages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Ne
11、ither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 1618-2009 (R2013)UL COPY
12、RIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 23, 2015 WALL PROTECTORS, FLOOR PROTECTORS, AND HEARTH EXTENSIONS - UL 1618 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMIS
13、SION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 4 3 Units of Measurement .5 4 Undated References 5 5 Glossary .5 CONSTRUCTION 6 Materials .6 7 Assembly 7 7.1 General .7 7.2 Joints .7 7.3 Grounding .8 7.4 Spacing .8 PERFORMANCE 8 General 8 9 Test Installation .9 10 Accelerated Aging Test 1
14、0 11 Thermal Resistivity Test .10 12 Radiant Panel Test .11 13 Burning Brand Test for Floor Protectors .11 13.1 General .11 13.2 Size and construction of brand .11 13.3 Ignition of brand 12 13.4 Test conditions .13 13.5 Duration of test 13 14 Impact and Strength Test 13 15 Reduced Clearance Test for
15、 Wall Protectors .13 MARKINGS 16 General 14 INSTALLATION INSTRUCTIONS 17 General 15 18 Floor Protectors 16 19 Wall Protectors .17 APPENDIX A Standards for ComponentsA1 OCTOBER 23, 2015 WALL PROTECTORS, FLOOR PROTECTORS, AND HEARTH EXTENSIONS - UL 1618 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURT
16、HER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover wall protectors, oor protectors, and hearth extensions that are intended for use with heat producing devices, such as replaces, replace stoves, replace inserts, and solid-fuel type room heat
17、ers. 1.2 Wall protectors, oor protectors, and hearth extensions are intended for installation in accordance with the Standard for Chimneys, Fireplaces, Vents, and Solid-Fuel Burning Appliances, NFPA 211. 1.3 The factory-built replaces with which these products are used are intended to comply with th
18、e Standard for Factory-Built Fireplaces, UL 127. 1.4 The replace stoves with which these products are used are intended to comply with the Standard for Fireplace Stoves, UL 737. 1.5 The solid-fuel type room heaters with which these products are used are intended to comply with the Standard for Room
19、Heaters, Solid-Fuel Type, UL 1482. 1.6 The pellet-fuel type room heaters with which these products are used are intended to comply with the Standard for Room Heaters, Pellet Fuel-Burning Type, ASTM E1509. 1.7 Floor protectors are not evaluated in regard to oor protection with substantial amounts of
20、fuel burning directly on the oor protector surface. 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered
21、by this standard. 2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall b
22、e used in accordance with its rating established for the intended conditions of use. 2.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding
23、 specied limits, and shall be used only under those specic conditions. OCTOBER 23, 2015 WALL PROTECTORS, FLOOR PROTECTORS, AND HEARTH EXTENSIONS - UL 1618 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Units of Measurement 3.1 Values sta
24、ted without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 4 Undated References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL16182015ULSTANDARDFORSAFETYWALLPROTECTORSFLOORPROTECTORSANDHEARTHEXTENSIONSSECONDEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJANUARY102018PDF

链接地址:http://www.mydoc123.com/p-1067580.html