SANS 794-2009 Aggregates of low density《低密度集料》.pdf
《SANS 794-2009 Aggregates of low density《低密度集料》.pdf》由会员分享,可在线阅读,更多相关《SANS 794-2009 Aggregates of low density《低密度集料》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-19242-6 SANS 794:2009 Edition 2.2 Any reference to SABS 794 is deemed to be a reference to this standard (Government Notice No. 1373 of 8
4、November 2002)SOUTH AFRICAN NATIONAL STANDARD Aggregates of low density Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS This standard may only be used and printed by approved subscription a
5、nd freemailing clients of the SABS.SANS 794:2009 Edition 2.2 Table of changes Change No. Date Scope Amdt 1 2002 Amended to update references. Amdt 2 2009 Amended to change the designation of SABS standards to SANS standards, to update the contact details for ASTM, to correct a cross-reference, and t
6、o update referenced standards. Acknowledgement The SABS Standards Division wishes to acknowledge the valuable assistance derived from publications of the following organizations: American Society for Testing and Materials British Standards Institution South African Council for Scientific and Industr
7、ial Research Foreword This South African standard was approved by National Committee SABS SC 59A, Construction standards Cement, lime and concrete, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was published in Januar
8、y 2009. This document supersedes SABS 794:2002 (edition 2.1). A vertical line in the margin shows where the text has been technically modified by amendment No. 2. This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 794:2009 Edition 2.2 1 Conte
9、nts Page Acknowledgement Foreword 1 Scope . 3 2 Definitions 3 3 Physical requirements 4 4 Chemical requirements 5 5 Sampling and compliance with the specification . 6 6 Physical test methods 7 6.1 Bulk density 7 6.2 Grading analysis 8 6.3 Soundness . 8 6.4 Thermal conductivity 11 6.5 Shrinkage . 16
10、7 Chemical test methods 17 7.1 Organic impurities 17 7.2 Sulphur trioxide content . 17 7.3 Sulphide sulphur content . 18 7.4 Loss on ignition 20 7.5 Iron content 20 Annex A Applicable standards . 22 Annex B Notes to purchasers 22 Annex C Bulk densities of aggregates of low density commonly used . 23
11、 Annex D Autoclave: Safety precautions 23 This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 794:2009 Edition 2.2 2 This page is intentionally left blank This standard may only be used and printed by approved subscription and freemailing clie
12、nts of the SABS.SANS 794:2009 Edition 2.2 3 Aggregates of low density 1 Scope 1.1 This specification covers inorganic aggregates of low density for use in structural and insulating concretes and in plaster. NOTE 1 The titles of standards referred to by number in the specification are given in annex
13、A. NOTE 2 Requirements that must be specified by the purchaser are listed in annex B. NOTE 3 The bulk densities of aggregates of low density commonly used are given in annex C. NOTE 4 Safety precautions in the use of an autoclave are given in annex D. 2 Definitions For the purposes of this specifica
14、tion the following definitions shall apply: 2.1 aggregate material that is mixed with an inorganic binder to provide the bulk in concrete and plaster 2.2 aggregate of low density aggregate of bulk density not exceeding 1 000 kg/m 32.3 clinker well-burnt furnace residues that have been fused or sinte
15、red into lumps 2.4 coarse aggregate aggregate of which at least 90 % (m/m) is retained on a sieve of nominal square aperture size 4,75 mm 2.5 fine aggregate aggregate of which at least 90 % (m/m) passes through a sieve of nominal square aperture size 4,75 mm 2.6 lot that quantity of fine aggregate o
16、r of coarse aggregate of one nominal size, from one manufacturer, in one vehicle or bin or in one stock pile of not more than approximately 100 m 3submitted at any one time for testing This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 794:20
17、09 Edition 2.2 4 3 Physical requirements 3.1 Bulk density The bulk density of the aggregate, determined in accordance with 6.1, shall not exceed 1 000 kg/m 3 . 3.2 Grading 3.2.1 Fine aggregates for plaster The grading of fine aggregates for plaster, determined in accordance with 6.2, shall be within
18、 the relevant limits given in table 1. Table 1 Grading of fine aggregates for plaster 1 2 Sieve aperture size* m % (m/m) passing the sieve 4 750 2 360 150 100 90 100 0 10 * Complying with SANS 3310-1 Amdt 13.2.2 Aggregates for insulating concrete The grading of aggregates for insulating concrete, de
19、termined in accordance with 6.2, shall be within the relevant limits given in table 2. Table 2 Grading of aggregates for insulating concrete 1 2 3 Sieve aperture size* % (m/m) passing the sieve mm Fine aggregate Nominal 13,2 mm aggregate 19 13,2 4,75 100 100 100 100 90 100 0 10 2,36 0,150 90 100 0 1
20、0 * Complying with SANS 3310-1 and SANS 3310-2. Amdt 1 This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 794:2009 Edition 2.2 5 3.2.3 Aggregates for structural concrete The grading of aggregates for structural concrete, determined in accorda
21、nce with 6.2, shall be within the relevant limits given in table 3. Table 3 Grading of aggregates for structural concrete 1 2 3 4 5 Sieve aperture size* % (m/m) passing the sieve mm Fine aggregate Nominal 13,2 mm aggregate Nominal 19,0 mm aggregate Nominal 26,5 mm aggregate 17,5 26,5 19,0 100 100 85
22、 100 100 85 100 0 50 13,2 9,5 6,70 100 85 100 0 55 0 25 0 50 0 25 0 5 0 25 0 5 4,75 0,150 90 100 0 10 0 10 * Complying with SANS 3310-1 and SANS 3310-2. Amdt 13.3 Soundness Aggregates having a bulk density exceeding 250 kg/m 3shall show no pop-outs when tested in accordance with 6.3.1. In the case o
23、f clinker aggregates the expansion, determined in accordance with 6.3.2, shall not exceed 6 mm. 3.4 Insulating properties of aggregates for insulating plasters and concretes When an aggregate for use in an insulating plaster or concrete is required by the purchaser, the average thermal conductivity
24、at 20 C of the plaster or concrete specimens, determined in accordance with 6.4, shall not exceed the appropriate maximum value given in column 2 of table 4. When the aggregate is to be used in plaster or concrete for use at high temperatures, the average thermal conductivity at 400 C of the specime
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS7942009AGGREGATESOFLOWDENSITY 密度 集料 PDF
