1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22337-3 SANS 5941:2009 Edition 2SOUTH AFRICAN NATIONAL STANDARD Carbon dioxide content of coal (titrimetric method) Published by SABS Stan
4、dards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 5941:2009 Edition 2 Table of changes Change No. Date S
5、cope Foreword This South African standard was approved by National Committee SABS SC 27B Solid mineral fuels Test methods, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was published in April 2009. This document super
6、sedes SABS SM 5941:1980 (edition 1). This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 5941:2009 Edition 2 1 Carbon dioxide content of coal (titrimetric method) 1 Scope This standard specifies a volumetric method for the determination of the
7、 carbon dioxide content of coal. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) ap
8、plies. Information on currently valid national and international standards can be obtained from the SABS Standards Division. ISO 3696, Water for analytical laboratory use. Specification and test methods. SANS 18283, Hard coal and coke Manual sampling. 3 Principle Coal passing a 212 m test sieve is t
9、reated with hydrochloric acid, which reacts with the carbonates present in the coal to liberate carbon dioxide. The carbon dioxide evolved from the decomposition of the carbonates is absorbed in benzylamine solution. The benzylamine salt formed is titrated with a solution of potassium methoxide in a
10、 mixture of toluene and methanol, using thymol blue as indicator. NOTE 1 Results obtained with this method should be comparable with results obtained using SANS 939 and SANS 940. NOTE 2 The determination is carried out in a closed circuit (see figure 1). 4 Apparatus 4.1 Absorption flask assembly, th
11、at is clean, dry, made up of boro-silicate glass and that consists of a 25 mL round-bottomed flask fitted (by means of ground joints) with a burette of capacity 10 mL graduated at 0,02 mL intervals, and an air inlet tube that reaches to the bottom of the flask (see figure 1). NOTE 1 The absorption f
12、lask assembly (and the assembly in 4.6) may be cleaned by means of a strong solution of potassium dichromate in sulfuric acid. NOTE 2 It is convenient to use an automatic type of burette fitted preferably with a polytetrafluoroethylene tap. This standard may only be used and printed by approved subs
13、cription and freemailing clients of the SABS.SANS 5941:2009 Edition 2 2 4.2 Balance, that has a sensitivity of 0,1 mg. 4.3 Flow meter, that is capable of measuring rates of flow of air up to 40 cm 3 /min. 4.4 Heating mantle, that is suitable for heating the reaction flask. 4.5 Pump, that is capable
14、of circulating air through the system at a rate of approximately 35 cm 3 /min. 4.6 Reaction flask assembly, that is clean, dry, made up of borosilicate glass, and that consists of a 50 mL, flat-bottomed flask fitted (by means of ground joints) with a tap funnel, a double-surface condenser of effecti
15、ve length of 100 mm, and an air inlet tube that reaches to the bottom of the flask (see figure 1). 5 Reagents NOTE Unless otherwise specified, use only water that complies with the requirements of ISO 3696, and that is free from carbon dioxide and reagents of analytical grade or (when such grade is
16、unobtainable) of the purest grade available. (Distilled or de-mineralized water may be freed from carbon dioxide by boiling it gently for 15 min.) 5.1 Hydrochloric acid, c(HCL) = 3 mol/L 5.2 Absorption mixture, prepared by mixing three volumes of 95 %(volume fraction) ethanol with 1 volume of benzyl
17、amine (C 6 H 5 CH 2 N 2 ) and 3 volumes of dioxan (OCH 2 OCH 2CH 2CH 2 ) 5.3 Standard potassium methoxide (CH 3OK.2CH 3OH) solution 0,1 mol/L, in a toluene-and- methanol mixture and standardized in triplicate as follows, using fresh portions of the sodium carbonate solution for each determination: P
18、ipette 10 mL of the standard sodium carbonate solution (see 5.4) into the reaction flask and carry out the test as described in clause 6, but omitting the coal sample. Calculate the carbon dioxide equivalent, F, of the potassium methoxide solution from the following formula and use the mean of the t
19、hree determinations: F = V 10where F is the carbon dioxide equivalent of the potassium methoxide solution in milligrams per millimetres V is the volume of potassium methoxide used in millilitres5.4 Standard sodium carbonate solution, 0,045 mol/L (1 mL = 1 mg CO 2 ). Dissolve 1,204 g of anhydrous sod
20、ium carbonate (previously dried at 260 C for 30 min) in water in a 500 mL volumetric flask, dilute to the mark with water, and mix well. 5.5 Thymol blue indicator, a mass fraction of 0,2 % i n dioxan solution. This standard may only be used and printed by approved subscription and freemailing client
21、s of the SABS.SANS 5941:2009 Edition 2 3 6 Procedure NOTE Before commencing any series of determinations check the apparatus for leaks. 6.1 Condition the 212 m sample, prepared in accordance with the relevant method in SANS 18283, by so exposing it for at least 30 min in a thin layer as to allow its
22、 moisture content to attain equilibrium with the laboratory atmosphere. 6.2 Mix the conditioned sample thoroughly (preferably by mechanical means) for at least 1 min. 6.3 Carry out duplicate determinations. 6.4 Accurately weigh out approximately 0,5 g of the coal sample, transfer it to the reaction
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS59412009CARBONDIOXIDECONTENTOFCOALTITRIMETRICMETHOD 中的 二氧化碳 含量 滴定法 PDF

链接地址:http://www.mydoc123.com/p-1031140.html