SAE AS 6171 3-2016 Techniques for Suspect Counterfeit EEE Parts Detection by X-ray Fluorescence Test Methods.pdf
《SAE AS 6171 3-2016 Techniques for Suspect Counterfeit EEE Parts Detection by X-ray Fluorescence Test Methods.pdf》由会员分享,可在线阅读,更多相关《SAE AS 6171 3-2016 Techniques for Suspect Counterfeit EEE Parts Detection by X-ray Fluorescence Test Methods.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2016 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on thisTechnical Report, please visithttp:/standards.sae.org/AS6171/3AEROSPACESTANDARDAS6171/3Issued 2016-10Techniques for Suspect/Counterfeit EEE Parts Detection by X-
5、ray Fluorescence Test MethodsRATIONALESince counterfeit electrical, electronic, and electromechanical (EEE) components are likely to have some level of material difference from the genuine components, techniques that identify the chemical elements in different areas of a part are essential to benchm
6、arking authentic parts (exemplars) and comparing them to parts under consideration. X-ray fluorescence (XRF) is one such technique that can be applied both to the external surfaces and internal elements of a part. The method itself is nondestructive by nature.INTRODUCTIONBecause many methods of coun
7、terfeiting of EEE components involve change of material from the original part, X-ray fluorescence (XRF) spectroscopy can provide a method of inspection of parts and detecting differences in their material composition. The method has been used extensively to detect nonconforming parts in electronics
8、 and in many other product areas. The implementation of RoHS1 requirements of the European Union and similar laws in other countries, resulted in wide spread use of XRF testing to confirm that electronic part leads do or do not contain lead (Pb). This document provides an introduction to the theory
9、and practice for application to counterfeit electronic part detection.TABLE OF CONTENTS1. SCOPE 31.1 Purpose. 32. REFERENCES 32.1 Applicable Documents 32.1.1 SAE Publications. 32.2 Related Publications . 32.3 Terms and Definitions . 42.4 Acronyms and Abbreviations 43. DESCRIPTION OF METHODOLOGY/PROC
10、EDURE 43.1 Material Control/ESD Handling . 63.2 Additional Considerations . 64. TEST EQUIPMENT AND CALIBRATION. 64.1 Equipment . 64.1.1 Benchtop XRF. 64.1.2 Hand-Held XRF. 71 Restrictions on Hazardous SubstancesSAE INTERNATIONAL AS6171/3 Page 2 of 224.2 Analysis Software 74.3 Selection Summary of Ty
11、pe of XRF Tool 74.4 Controls and Calibration 85. REQUIREMENTS . 85.1 Sampling . 85.2 Categories of Testing/Risk Levels 85.3 Comparison of Test Results for Determination of Suspect/Counterfeit 95.4 Counterfeit Detection Test Procedure. 95.4.1 Generic Steps in Performing a Bulk Material Analysis with
12、any XRF Instrument. 105.4.2 Plating Thickness Measurement. 115.4.3 When to Perform Plating Thickness Measurement 125.4.4 Steps in Performing Analysis on a Small Sample with a Hand-held System . 145.4.5 Generic Steps in Performing Analysis on a Large Sample, with No X-ray Blocking Present, with a Han
13、d-held System 155.5 Test Plan . 155.6 Analysis and Interpretation of Results 155.7 Test Report . 175.8 Training and Certification 185.8.1 Personnel Qualification and Certification 185.8.2 Laboratory/Test Facility. 205.8.3 Proficiency. 215.9 Data Retention Requirements. 226. NOTES 226.1 Revision Indi
14、cator 22FIGURE 1 XRF PRINCIPLE OF OPERATION. 4FIGURE 2 SCHEMATIC OF AN XRF SYSTEM. 5FIGURE 3 UNUSABLE XRF SPECTRAL INFORMATION 10FIGURE 4 XRF SPECTRUM WITH ELEMENT PEAKS 11FIGURE 5 CIRCULAR CONNECTOR WITH CONTACTS 14FIGURE 6 HAND-HELD POSITIONED TO ANALYZE CONTACTS . 14TABLE 1 RECOMMENDED XRF TESTS
15、8TABLE 2 EXAMPLE INDICATIONS OF SUSPECT COUNTERFEIT COMPONENTS (SEE NOTE 1 REGARDING CONFORMANCE REQUIREMENTS) 17SAE INTERNATIONAL AS6171/3 Page 3 of 221. SCOPEXRF technique for counterfeit detection is applicable to electrical, electronic and electromechanical (EEE) parts as listed in AS6171 Genera
16、l Requirements. In general, the detection technique is meant for use on piece parts prior to assembly on a circuit board or on the parts that are removed from a circuit board. The applicability spans a large swath of active, passiveand electromechanical parts.If AS6171/3 is invoked in the contract,
17、the base document, AS6171 General Requirements shall also apply.1.1 PurposeThe purpose of this document is to provide information and instructions on how to use XRF as a technique to verify the materials and finishes of EEE parts to compare with the original design, construction and material require
18、ments. The process of detection is based on identification of elements (or absence thereof) in a component. The indication of counterfeitrisk can also be based on the presence of and concentration levels of materials under consideration. The counterfeit detection process using XRF can be applied to
19、components as received or on delidded, decapsulated, or otherwise prepared parts. For reliable decision making, findings from XRF analysis need to be compared with material composition information of appropriate exemplars, compared with each other in the lot, or compared with the original manufactur
20、ers documented specifications.2. REFERENCES2.1 Applicable DocumentsThe following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purc
21、hase order. In theevent of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.2.1.1 SAE PublicationsAvailable f
22、rom SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or +1 724-776-4970 (outside USA), www.sae.org.1 AS5553, Fraudulent/Counterfeit Electronic Parts; Avoidance, Detection, Mitigation, and Disposition.2 AS6171, Test Method Standard, Gener
23、al Requirements, Suspect/Counterfeit, Electrical, Electronic, and Electromechanical Parts.2.2 Related PublicationsThe following publications are provided for information purposes only and are not a required part of this SAE Aerospace Technical Report.1 JEDEC, JESD 213, Standard Test Method Utilizing
24、 X-ray Fluorescence (XRF) for Analyzing Component Finishes and Solder Alloys to Determine Tin (Sn) - Lead (Pb) Content.2 Naval Air Systems Command, “Solder Alloy Analysis: X-ray Fluorescence Test Equipment Evaluation Report,” NAVAIRin conjunction with Crane Division, Naval Surface Warfare Center, De
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS617132016TECHNIQUESFORSUSPECTCOUNTERFEITEEEPARTSDETECTIONBYXRAYFLUORESCENCETESTMETHODSPDF

链接地址:http://www.mydoc123.com/p-1025115.html