1、Lessons Learned Entry: 1581Lesson Info:a71 Lesson Number: 1581a71 Lesson Date: 2005-27a71 Submitting Organization: JPLa71 Authored by: David J. OberhettingerSubject: Thermal Sensor Installation Failures Remain a Problem Abstract: There is an extensive history of resistance thermal device (RTD) failu
2、res on NASA and DOD missions due to thermally-induced mechanical stress. Recent MER ground and in-flight failures, including some failures in mission critical MER applications, suggest that these devices remain sensitive to variations in the mounting configuration. Perform Package Qualification Veri
3、fication (PQV) for all critical RTD applications. For non-critical applications, develop standard, flight qualified installations and methods, and track the part pedigree. Description of Driving Event: During Mars Exploration Rover (MER-2) system-level thermal-vacuum (STT) test, it was discovered th
4、at one of two platinum resistance thermometers (PRTs) that provide temperature calibration for the Miniature Thermal Emission Spectrometer (MTES) had failed (Reference (1). The PRTs had been installed by the contractor using a liberal amount of a rigid adhesive that transferred the thermal strain di
5、rectly to the relatively brittle ceramic body of the PRT, overstressing it to failure. The mounting method had not been sujected to Package Qualification Verification (PQV), and subsequent coupon tests showed that the mounting method was consistent with failure within a few thermal cycles. One inter
6、nal calibration target PRT on each of the Mars rovers was reworked by JPL using a ribbon of RTV, a configuration that passed PQV. (The others were not replaced because it would have invalidated the calibration.) Three months after landing on Mars, 6 internal and external calibration target PRTs on R
7、overs MER-1 and MER-2 that were bonded using the original method failed, but the 2 reworked PRTs subjected to PQV functioned properly. The loss of a temperature sensor on the MTES could result in the loss of a major portion of the rovers science return. In an unrelated incident during an STT of MER-
8、1 (Reference (2), the azimuth actuator PRT failed on the Instrument Deployment Device (IDD, or rover arm). This failure occurred shortly after the IDD heaters, used at the conclusion of the test to return the spacecraft to ambient temperature, were Provided by IHSNot for ResaleNo reproduction or net
9、working permitted without license from IHS-,-,-powered off. In this case, bonding adhesive likely migrated from under the PRT body and onto the lead wires (Figure 1), and the different coefficients of thermal expansion caused the contracting platinum wire to break and open at cold temperature. inser
10、t figure and picture Figure 1. PRT bonded to the actuator case with excessive epoxy adhesive, covering the leads (small wire loops indicated byarrow) Also, a PRT on the MER-2 Lander Petal Actuator failed in flight (Reference (3). Thermal sensors provide vital information on spacecraft and instrument
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS15812005LESSONSLEARNEDTHERMALSENSORINSTALLATIONFAILURESREMAINAPROBLEMPDF

链接地址:http://www.mydoc123.com/p-1019204.html