1、PFI Standard ES-32 | Denotes Revision (Revised December 2013) TOOL CALIBRATION Prepared by Pipe Fabrication Institute Engineering Committee All PFI Standards are advisory only. There is no agreement to adhere to any PFI Standard and their use by anyone is entirely voluntary. Copyright by PIPE FABRIC
2、ATION INSTITUTE Dedicated to Technical Advancements and Standardization in the Pipe Fabrication Industry Since 1913 USA 511 Avenue of Americas, # 601 New York, NY 10011 CANADA 655, 32ndAvenue, # 201 Lachine, QC H8T 3G6 WEB SITE www.pfi-institute.org TOOL CALIBRATION PFI Standard ES-32 | Denotes Revi
3、sion (Revised December 2013) 1. Scope 1.1 To verify conformance to the established requirements in the fabrication of piping subassemblies, it is necessary to assure that all tools, gauges, and instruments shall be in good working order operated per manufacturers recommended procedures, and be calib
4、rated as required. 1.2 It is the intent of this standard to provide guidance for establishing the minimum requirements for calibration, accuracy and documentation of equipment used in the inspection and fabrication activities. 2. Definitions 2.1 Calibration - A comparison of a device with a higher r
5、anking reference device traceable to factory standards (when such standards exist) and the adjustment of the device being calibrated to meet permissible tolerances. 2.2 Device - A tool, gauge or other equipment used to determine whether prescribed characteristics have been obtained. 2.3 Reference De
6、vice - A device of higher accuracy used only for calibration of working devices. 3. Devices Subject to Calibration 3.1 Calibrated Devices 3.1.1 Reference devices. 3.1.2 Inspection, examination or testing devices used for final acceptance of a fabrication. 3.1.3 Process control devices, such as tempe
7、rature controlling, recording or indicating devices, electrical meters, etc. 3.2 Non-Calibrated Devices 3.2.1 Non-precision measuring devices, such as measuring tapes, fillet weld gauges, squares, bubble levels, etc., need not be calibrated. However, it is recommended that an initial check be made p
8、rior to issuance for use to detect possible manufacturing errors or defects. 3.2.2 Meters subject to adverse operating conditions (such as meters on welding machines) need not be calibrated, provided other means are established for control of the process. 4. Calibration Frequency 4.1 Table 1 provide
9、s guidance as to the frequency of calibration of selected devices. 4.2 The calibration frequency of devices not specifically listed in Table 1 shall be determined by the fabricator based on the past performance and adjustments required during calibration. 4.3 The intervals given in Table 1 reflect s
10、uggested frequencies and should be adjusted to meet particular needs when necessary. 4.4 Devices which require calibration prior to each use shall be so identified. 5. Calibration Tolerances 5.1 Calibration tolerances should be determined based on the manufacturers published accuracy for the device.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PFIES322013TOOLCALIBRATIONPDF