NFPA 1971 AMD 3-2013 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting (Effective Date 08 20 2013).pdf
《NFPA 1971 AMD 3-2013 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting (Effective Date 08 20 2013).pdf》由会员分享,可在线阅读,更多相关《NFPA 1971 AMD 3-2013 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting (Effective Date 08 20 2013).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 Tentative Interim Amendment NFPA1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting 2013 Edition Reference: Various TIA 13-3 (SC 13-8-23/TIA Log #1100) Pursuant to Section 5 of the NFPA Regulations Governing the Development of NFPA Standards, the National
2、Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2013 edition. The TIA was processed by the Technical Committee on Structural and Proximity Fire Fighting Protectiv
3、e Clothing and Equipment and the Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment, and was issued by the Standards Council on August 1, 2013, with an effective date of August 20, 2013. A Tentative Interim Amendment is tentative because it has not been processed
4、through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a public input of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making
5、process. 1. Revise 7.7.22 to read as follows: 7.7.22 Gloves shall be tested for grip as specified in Section 8.38, Grip Test, and shall not have a drop of force of more than 30 percent from the peak pull force value in any 0.2 second interval. 2. Revise Section 8.38 to read as follows: 8.38.2.1 Samp
6、les for conditioning shall be whole gloves pairs. 8.38.3.4 Specimen glove pairs shall be tested after being wet conditioned for wet conditions as specified in 8.1.9. 8.38.4.1 Pulling Device. The pulling device shall be a 3.2 cm (1 in.) diameter fiberglass pole attached to an overhead calibrated forc
7、e measuring device in such a fashion that pulls on the pole will be perpendicular to the ground and downward in direction. This pole shall be used until surface degradation occurs. The force measuring system shall provide a graphical plot of force-vs-time. 8.38.5.1 Test subjects shall be selected so
8、 that their hand dimensions are as close as possible to the middle of the range for hand length and hand circumference as specified in Table 6.7.6.1 (ab) and Table 6.7.6.1(d) for size small and size large gloves. At least three test subjects shall be selected for both size small and size large. 8.38
9、.5.4 The test subject and the test subjects hand shall be positioned as shown in Figure 8.38.5.4(a) and Figure 8.38.5.4(b), and as described below: shall then make three pulls on the pulling device with gloves with peak and minimum pull force values measured. Pulls shall be performed as described 8.
10、38.5.4.1 through 8.38.5.4.6. The test subject shall extend the arms in front of the body at shoulder height to grab the pulling device for pulling vertically down from the ceiling. Figure 8.38.5.4 (a) Position of test subject body, arms, and hands with respect to pole. Photo Courtesy Intertek Testin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA1971AMD32013STANDARDONPROTECTIVEENSEMBLESFORSTRUCTURALFIREFIGHTINGANDPROXIMITYFIREFIGHTINGEFFECTIVEDATE08202013PDF

链接地址:http://www.mydoc123.com/p-1008412.html