NAVY UFGS-21 12 00-2011 STANDPIPE SYSTEMS《储水管系统》.pdf
《NAVY UFGS-21 12 00-2011 STANDPIPE SYSTEMS《储水管系统》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-21 12 00-2011 STANDPIPE SYSTEMS《储水管系统》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-21 12 00 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-21 12 00 (April 2006)UFGS-13975 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 21 - FIRE SUPPRESSIONSECTI
2、ON 21 12 00STANDPIPE SYSTEMS05/11PART 1 GENERAL1.1 REFERENCES1.2 RELATED REQUIREMENTS1.3 SYSTEM DESCRIPTION1.4 SYSTEM DESCRIPTION1.4.1 Residual Pressure1.4.2 Friction Losses1.4.3 Water Supply1.4.4 Standpipe System Drawings1.5 SUBMITTALS1.6 QUALITY ASSURANCE1.6.1 Qualifications of Installer1.6.2 Syst
3、em As-Built Drawings1.7 DELIVERY, STORAGE AND HANDLINGPART 2 PRODUCTS2.1 ABOVEGROUND PIPING SYSTEMS2.1.1 Pipe and Fittings2.1.2 Pipe Hangers and Supports2.1.3 Valves2.1.3.1 Hose Valves2.1.4 Identification Signs2.1.5 Waterflow Test Connection2.1.6 Main Drains2.1.7 Pipe Sleeves2.1.7.1 Sleeves in Mason
4、ry and Concrete Walls, Floors, and Roofs2.1.7.2 Sleeves in Partitions2.1.8 Escutcheon Plates2.1.9 Fire Department Connections2.1.10 Alarm Valves2.1.11 Water Motor Alarms2.1.12 Pressure Switch2.1.13 Waterflow DetectorSECTION 21 12 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking pe
5、rmitted without license from IHS-,-,-2.1.14 Fire Hose Cabinets2.1.15 Valve Tamper Switch2.1.16 Fire Pumps2.1.17 Backflow Preventer2.2 BURIED PIPING SYSTEMS2.2.1 Buried Pipe and Fittings2.2.2 Buried Utility Warning and Identification Tape2.3 ELECTRICAL WORK2.3.1 WiringPART 3 EXECUTION3.1 EXCAVATION,
6、BACKFILLING, AND COMPACTING3.2 CONNECTIONS TO EXISTING WATER SUPPLY SYSTEMS3.3 STANDPIPE SYSTEM INSTALLATION3.4 DISINFECTION3.5 FIELD PAINTING3.5.1 Piping Labels3.6 ELECTRICAL WORK3.6.1 Wiring3.7 FLUSHING3.8 FIELD QUALITY CONTROL3.8.1 Preliminary Tests3.8.2 Formal Inspection and Tests (Acceptance Te
7、sts)3.8.2.1 Flow Test3.8.2.2 Alarm Testing3.8.3 Additional Tests- End of Section Table of Contents -SECTION 21 12 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-21 12 00 (May 2011)-Preparing Activity: NA
8、VFAC SupersedingUFGS-21 12 00 (April 2006)UFGS-13975 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 21 12 00STANDPIPE SYSTEMS05/11*NOTE: This guide specification covers the requirements for dry and wet standpipe and hose systems fo
9、r fire extinguishing in multi-story and multi-level buildings.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements b
10、y adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specificati
11、on are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: Standpipe system requirements must conform to the current edition of UFC 3-600-01, “Fire Protection Engineering for Facilities“ and NFPA 14.*NOTE: Project drawings should indicate the following information:1. Location a
12、nd detail of each standpipe supply riser, alarm valve, water motor alarm, fire department inlet connection, pressure/flow switch, fused disconnect switch, and associated electrical connections;2. Location where each standpipe system begins SECTION 21 12 00 Page 3Provided by IHSNot for ResaleNo repro
13、duction or networking permitted without license from IHS-,-,-including connection to water distribution system piping;3. Location of standpipe system control valves, post indicator valves, or wall indicator valves;4. Location of fire hose cabinets when required, also indicate when fire extinguishers
14、 will be stored within the fire hose cabinet;5. Details of anchoring piping, including pipe clamps and tie rods, or mechanical retainer glands.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referr
15、ed to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also us
16、e the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of th
17、is specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN WATER WORKS ASSOCIATION (AWWA)AWWA C651 (2005; Errata 2005) Standard for Disinfecting Water MainsASTM INTERNATIONAL (ASTM)ASTM C 1036 (2006) Standard Specification for F
18、lat GlassFM GLOBAL (FM)FM APP GUIDE (updated on-line) Approval Guide http:/ 21 12 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-FOUNDATION FOR CROSS-CONNECTION CONTROL AND HYDRAULIC RESEARCH (FCCCHR)FCCCHR List (continuously updated) List
19、of Approved Backflow Prevention AssembliesNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 13 (2010; Errata 10-1; TIA 10-1) Standard for the Installation of Sprinkler SystemsNFPA 14 (2010) Standard for the Installation of Standpipes and Hose SystemsNFPA 24 (2010) Standard for the Installation of Priv
20、ate Fire Service Mains and Their AppurtenancesNFPA 70 (2011) National Electrical CodeNFPA 72 (2010; TIA 10-4) National Fire Alarm and Signaling CodeUNDERWRITERS LABORATORIES (UL)UL Fire Prot Dir (2011) Fire Protection Equipment Directory1.2 RELATED REQUIREMENTSSection 23 03 00.00 20 BASIC MECHANICAL
21、 MATERIALS AND METHODS applies to this section with additions and modifications specified herein.1.3 SYSTEM DESCRIPTIONDesign and provide new manual dry Class Icombination automatic wet Class I standpipe and fire sprinkler systems as shown. 1.4 SYSTEM DESCRIPTION*NOTE: Design standpipe systems in ac
22、cordance with the current edition of MIL-HDBK-1008 and NFPA 14. Provide pipe-sizing calculations to the Division Fire Protection Engineer (FPE) for review. Class I standpipes are for fire department use only and will normally be the type provided. Wet standpipes must be protected from freezing. It i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS2112002011STANDPIPESYSTEMS 储水 系统 PDF

链接地址:http://www.mydoc123.com/p-984783.html