NAVY MIL-T-81533 A-1967 TRICHLOROETHANE 1 1 1 (METHYL CHLOROFORM) INHIBITED VAPOR DEGREASING《蒸气脱脂1 1 1三氯乙烷(甲基氯仿)的抑制》.pdf
《NAVY MIL-T-81533 A-1967 TRICHLOROETHANE 1 1 1 (METHYL CHLOROFORM) INHIBITED VAPOR DEGREASING《蒸气脱脂1 1 1三氯乙烷(甲基氯仿)的抑制》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-T-81533 A-1967 TRICHLOROETHANE 1 1 1 (METHYL CHLOROFORM) INHIBITED VAPOR DEGREASING《蒸气脱脂1 1 1三氯乙烷(甲基氯仿)的抑制》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、_- MIL-T-BL533A h each sample filled container shall also be weighed to determine the amount of contents. Any container in the sample, having one or more defects, or under required fill, shall be rejected and if the nwnber of defective containers in any sample exceeds the acceptance number for the a
2、pplicable sampling plan of Military Standard MIL-STD-105, the lot represented by the sample shall be rejected. 4.3.2 Lot acceDtance tests - The samples selected in accordance with 4.2.3 shall be subjected separately to the tests specified in 4,4. I. either sample fails one or more o2 these tests, th
3、e lot shall be rejected 4,40 Test procedures - 4,4.1 Nonvolatile residue - This determination shall be made in accordance with ASTM Method A, D-2109-64. A stream of warm (40 - 5OoC) dry, oil-free nitrogen or compressed air may be used to accelerate evapora- tion. The results shall be reported on a w
4、eight basis. - - “ ,“. %: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-81533A 4.4.2 Specific gravity - The specific gravity shall be determined in accordance with ASTM D-2111-64. 4,403 APHA color - Test in accordance with ASTM Method D-2108-
5、64, 4.4.4 Awearance - A portion of the well shaken sample shall be placed in a test tube and allowed to stand stoppered and undisturbed until bubbles have entirely disappeared. Examination shall be made by trmsmitted light for uniformity and freedom from particles, 4.4.5 1.1.1 Trichloroethane conten
6、t - The content of 1,1,1 trichloroethane, inhibited, shall be assayed in accordance with the following gas chromatographic procedure or one of equal or better sensi- tivity and accuracy, - 4.4,5,1 Apparatus - A gas chromatograph having the following minimum capabilities is recommended: Temperature c
7、ontrol system capable of maintaining the chromatographic column at prescribed temperature &0,5OC. Heated sample inlet. A differential katharometer (hot wire), thermistortype thermal conductivity detector or hydrogen flame detector. 4.4.5,2 Materials - The following materials are recommended: Chromat
8、opraphic column - Annealed copper or stainless steel tubing, 12 feet long?by 1/8-inch outside diameter (0.055-inch inside diameter). Column packing - Acid washed calcined-pink firebrick (Chromosorb P), 30 to 50U.S. Standard mesh, coated with 15 percent by weight of UNCON LB 1800X liquid phase. The c
9、ompleted column should be conditioned prior to initial use at 125OC, with helium gas flowing through it for 24 hours at a rate of 15 ml per minute. - 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- . MIL-T-81533A Carrier gas - Dry helium of 99.95
10、mole percent purity. Standard - Uninhibited 1,1,1 trichloroethane of .at least 98.0% purity. 4.405.3 Analysis conditions - The following analysis conditions are recommended: Column temperature - 6OoC isothermal. Detector temperature - 225OC, Sample inlet temperature - 200C. Sample size - 5 microlite
11、rs (to be injected by means of a precision 10 ul syringe via a heated inlst), Carrier gas flow - 15 ml per minute. Detector sensitivity - Sufficient to easily meet the 0.5 percent detection requirement set forth in 3.2. Bfiploying the operating conditions recommended, all constituents of methyl chlo
12、roform solvents should elute from the column in approximately 30 minutes. 4.4.5.4 Determination of 1.1.1 Trichloroethane content - Quanti- tative measurement of concentration of a constituent in a sample depends upon a determination of the peak area or peak height of the constituents chromatographic
13、 peak or area. Peak areas may be measured by any accepted method (planimeter, ball and disc integrator, electronic digital integrator, etc.) or may be approximated by multiplying the height of the peak by the width of the peak at the half-height. To obtain the percent concentra.tion of the 1,1,1 tri
14、chloroethane ina sample, a direct comparison is made of its peak area with the peak area of 1,1,1 trichloroethane in the standard, Both sample and standard must be analyzed under identical operating conditions. 4.4.6 Water content - The water content shall be determined in accordance with ASTM Metho
15、d D-1364-64, 4.4.7 Acidity (as HC1) 4.4.7.1 The acidity of the “as received“ material shall be determined by standard titration with ,O2 normal sodium hydroxide in - anhydrous methanol using bromothymol-blue as an indicator, - 6 LIj ?,-:* Provided by IHSNot for ResaleNo reproduction or networking pe
16、rmitted without license from IHS-,-,-NIL-T-BL533A h8 m 7777706 0322832 2 MIL-T-81533A 4.4.7.2 Acidity after accelerated oxidation - The general arrange- ment of the apparatus used is shown in figure 1. Two-hundred ml of the sample shall be placed in the boiling flask. One strip of steel 1/2 inch by
17、2 inches by 1/16 inch shall be suspending by means of an uncoated copper wire so it remains above the liquid level, and another strip 1/4 inch by 3/4 inch by 1/16 inch shall be placed in the bottom of the flask, The strips shall conform to S.A.E. steels within the range of 1010 to 1040 inclusive. Th
18、e oxygen delivery tube shall extend to within 1/4 inch of the bottom of the flask. The water shall be started through the condenser. The oxygen-flow shall be regulated to 18-12 bubbles per minute by adjusting the height of the water level above oxygen outlet in the pressure control cylinder. The hea
19、ting of the solution shall be started and the solvent refluxed for 48 hours. The solvent shall be cooled to ambient temperature, 25 ml shall be withdrawn and the acidity determined by the method described in 4.4.7.1, 4.4.8 - Free halogen - Transfer 10 ml of sample to a clean test tube. Add 10 ml of
20、distilled water, 5 drops of 10 percent potassium iodine solution (ACS Reagent) and one ml of starch solution (ACS Reagent). Shake for one minute. A blue color in the aqueous layer indicates the presence of free halogen. 4.4.9 Etals corrosion - Prepare 1/2 inch by 5 inch panels of each of the followi
21、ng metals: . Aluminum alloy (QQ-A-250/4C temper T-41, Steel (MIL-S-7952) Magnesium (QQ-“44) and Titanium (MIL-T-90461, Polish panels with No, 1 emery cloth until the entire panel is bright, shiny and free from any oxide film or tarnish, Do not handle the panels with bare hands after polishing. Wash
22、with soap or detergent and water and rinse with distilled water. Was with acetone and allow to air-dry. Place each panel in separate 500 ml Erlenmeyer flask which has a ground glass neck, add sufficient 1,1,1 trichloroethane to form a layer of solvent one inch deep. Attach a reflux condenser and hea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT81533A1967TRICHLOROETHANE111METHYLCHLOROFORMINHIBITEDVAPORDEGREASING 蒸气 脱脂 111 三氯乙烷 甲基 氯仿 抑制

链接地址:http://www.mydoc123.com/p-982831.html