NAVY MIL-T-81148 B-1972 TRANSFORMER DISCRIMANATOR (FOR TORPEDO MARK 37 MODS 0 2 AND 3)《37号0 2及3型鱼雷鉴别器变压器》.pdf
《NAVY MIL-T-81148 B-1972 TRANSFORMER DISCRIMANATOR (FOR TORPEDO MARK 37 MODS 0 2 AND 3)《37号0 2及3型鱼雷鉴别器变压器》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-T-81148 B-1972 TRANSFORMER DISCRIMANATOR (FOR TORPEDO MARK 37 MODS 0 2 AND 3)《37号0 2及3型鱼雷鉴别器变压器》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Ii - -. - _- I .- I MIL-T-BLLq8B 13 7777706 0358707 b t MILITARY SPECIFICATION TWSFORMER, DISCRIMIMOR (For Torpedo Mark 37 Mods O, 2, and 3) MIL-T-8U48B( OS) 31 August 1972 Superseding MIL-T-81148A( Wep ) 21 October i965 This specification has been approved by the Naval Ordnance Systems Command, Dep
2、artment of the Navy 1. SCOPE 1.1 This specification establishes the requirements for the procure- ment of a Discriminator Transformer, NAVORD Dwg 1.563729, which is used in the enabler assedled unit of an acoustic panel. 2. APPLICABrn DOCUMENTS 2.1 The following documents of the issue in effect on d
3、ate of invita- tion for bids or request for proposal form General Specifica- tion for Capacitors, Fixed, Mica-Dielectric; General Specification for Capacitors, Fixed, Paper-Dielectric, Direct Current (Hermetically Sealed in Metallic Cases) Preservation, Methods of Provided by IHSNot for ResaleNo rep
4、roduction or networking permitted without license from IHS-,-,-MIL-T-BLL48B 13 m 7777906 0358708 8 m t -. MIL-T-81148B(OS) MIL-R-10509 MIL-S-19500 MIL-E-82590 STANDARDS Mi lit ary M IL-STD-105 Resistors, Fixed Film (High Stability), General Specification for Semiconductor Devices, General Specifi- c
5、ations for .Environmental Requirements and Tests (For Torpedo Mk 37 Components and As- semblies ) Sampling Procedures and Tables for Inspection by Attributes MIL-STD-129 Marking for Shipment and Storage MIL- STD-147 MIL-STD-202 DRAWINGS Naval Ordnance Systems Command Palletized and Containerized Uni
6、t Loads, 40“ x 48“ Pallets, Skids, Runners, or Pallet-Type Base. Test Methods for Electronic and Electrical Component Parts NAVORD dwg 1563729 Transformer, Discriminator (Copies of specifications, standards, drawings, and publications required by the contractor in connection with specific procuremen
7、t functions should be obtained from the procuring activity or as directed by the contracting officer. 1 2.2 Other publications. TTie folIowing documents fom a part ofthis- specification to the extent specified herein. the issue in effect on date of invitation for bids or request for proposals shall
8、apply. Unless otherwise indicated, National Bureau of Standards Publications Handbook H28 Screw-Thread Standards for Federal Services (Application for copies should be addressed to the Superintendent of Doc- uments, Government Printing Office, Washington, D.C. 20402,) 2 s- Provided by IHSNot for Res
9、aleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-8ULC8B( OS) United States of America Standards Institute USAS 32.2 1967 Graphic symbols for Electrical and Elec- tronics Diagrams ,- (Application for copies should be addressed to DOD Single Stock Point, U. S. Naval Supply
10、 Depot, Philadelphia, Pennsylvania 19120. ) 3. REQUIRFMENTS 3.1 Description. The discriminator tramformer is a plug-in assdly, composed of various electronic components, in a hermetically sealed metal container. equivalent direct current (c) output voltages. It is used in a circuit which converts fr
11、equency deviations to 3.2 General requirements 3.2.1 Preproduction sample. Unless otherwise specified in the contract or order, preproduction samples of the transformer shall be manufactured using the methods and procedures proposed for the production lot. These units shall be tested as specified in
12、 Section 4 herein and are for the purpose of determining, prior to starting production, that the contractor s production methods are capable of producing transformers that comply with the technical requirements of the contract. See 4.3.1. 3.2.2 Materials. Unless otherwise specified in the contract,
13、requisition, or order, al1 materials and purchased parts entering into the final as- sembly of the transformer shall conform strictly to the detailed require- ments indicated on the applicable drawings, specifications, and publica- tions listed in NAVORD Dwg 1563729: 3.2.3 Surface treatment, constru
14、ction, and dimensions. Surface treat- ment, construction, and dimensions for the transformer shall be in accordance with the applicable drawings, specifications, and publications listed in WVO Dwg 1563729. 3.2.4 Moisture, fungus, and corrosion. The transformer shall be rendered moisture, fungus, and
15、 corrosion resistant in accordance with detail require- ments specified on the rawings and specifications listed in NIVORD Dwg 1563729. 3.2.5 Marking. Marking of asseinblies, subasseniblies, and parts shall be 3.2.6 Threads. in accordance wi-Lh applicable drawings listed in NAVORD Dwg 1563729. Unles
16、s otherwise specified, all threads shall be in ac- cordance with National Bureau of Standards Eandbook 28. fit for threads shall be as specified on the applicable drawings. The class or 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-*XI.B( O
17、S) 3.2.7 Conflicting requirements. In the event of conflict between the documents referenced herein and the contents of this specification, the contents of this specification shall apply. 3.3 Symbols. Interpret schemtic diagram symbols in accordance with USAS Y32.27. 3.4 Performance requirements and
18、 product characteristics. The trans- former shall meet the following performa;nce requirements and product characteristics: 3.4.1 -. Dc - output voltages 3.4.1.1 The frequency necessary to produce zero voltage at output #i (see Figure i) of the transformer hal1 be 7000 plus or minus 50 Hertz (Hz), w
19、hen measured as specified in 4.5.4.2. 3.4.1.2 The frequency necessary to produce zero voltage at 0u.t;pu-t j#2 (see Figure 1) of the transformer shall be within plus or minus 10 z of the frequency measured in 3.4.1.1, when measured as specified in 4.5.4.2. * 3.4.2 Polarity of the output voltages 3.4
20、.2.1 The polarity of the voltage at output #i shall be negative when the frequency is less than the frequency in 3.4.1.1, when measured as specified in 4.5.4.3. 3.4.2.2 The polarity of the voltage at output #l shall be positive when the frequency is greater than the frequency in 3.4rl.1, when measur
21、ed as specified in 4.5.4.3. 3.4.2.3 The polarity of the voltage at output #2 shal be positive when the frequency is less than the frequency in 3.4.1.2, when measured as specified in 4.5.4.3. 3.4.2.4 The polarity of the voltage at output #2 shall be negative when the frequency is greater ehan the fre
22、quency in 3.4.1.2, when measured as specified in 4 . 5 . 4 . 3 . 3.4.3 Sensitivit The sensitivities shall be as follows, when measured as speciiiected to the following tests and examinations. Fail- ure to meet any requirement Specified herein shall be considered cause for rejection. 4.5.1 Test condi
23、tions. Unless otherwise specified, the transformer shall be subjected to quality conformance tests under the following conditions: 4.5.1.1 Temperature. Room ambient 65 degrees F to 95 degrees F (18.3 degrees Centigrade (c) to 35 degrees c). 4.5.l.2 Altitude. Normal grnima. .- 9 Provided by IHSNot fo
24、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-UB( OS) 4.5.1.3 Vibration. None. 4.5.1.4 Rumidity. Room ambient to 95 percent relative maximum. 4.5.2 Test and inspection equipment and facilities. The manufacturer shall furnish and maintain all necessary test equipm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT81148B1972TRANSFORMERDISCRIMANATORFORTORPEDOMARK37MODS02AND337 02 鱼雷 鉴别器 变压器 PDF

链接地址:http://www.mydoc123.com/p-982809.html