NAVY MIL-C-81343 C-1970 CONVERTER GROUP RADAR SCAN AN ASA-69《AN ASA-69雷达扫描变换器组》.pdf
《NAVY MIL-C-81343 C-1970 CONVERTER GROUP RADAR SCAN AN ASA-69《AN ASA-69雷达扫描变换器组》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-C-81343 C-1970 CONVERTER GROUP RADAR SCAN AN ASA-69《AN ASA-69雷达扫描变换器组》.pdf(55页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-C-813LI3C 58 W 7777706 0170201 7 W .- NIL4 -81343C(AS) 1-March 1970 . SUPERSEDING MIL-R-81343B (AS) - .- 1 April 1968 . odular Assemblies - irlien used, Nicroelectronic Modular Assemblies shall meet; the requiie- ments of AR-5. *3;2.3 Modules I - The electronic portions and Connections *3.3.3.1
2、Cables and Connectors - The equipment shall provide for the use of cables and connectors in accordance with Specification MIL-E-5400. Input power connectors shall conform to MIL-C-26482. conform to MIL-C-81511: be capable of satisfactory operation using external wiring in accordance with the applica
3、ble requirements of Specification MIL-W-5088. The external wiring shall be unshielded, except that a minimum number of the individual wires may be shielded when demonstrated as necessary to meet interference control requirements and provided the assembly of the cable to its plugs may be easily accom
4、plished. External cables and that portion of the connectors attached to the cables shall not be supplied as part of the equipment. control panels shall conform to the applicable requirements of Specification MIL-C-6781 except that control panels shall be gray per FED-STD-595 (Color No. 36231) with w
5、hite lights. The configuration of all control panels must be approved by the procuring activity prior to preproduction testing. Interchangeability - The equipment shall meet the interchangeability requirements of Specification Connectors used for digital transmissions shall *3.3.3.2 Interconnection
6、Cabling - The equipment shall . 3.3.4 Control Panels - All rack or console mounted *3.3.5 MIL-E-5400. 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-C-L343C 58 7777706 O370207 T W *3.3.6 Interference Control - The generation of radio interfer
7、ence by the equipment and vulnerability of the equipment to radio interference shall meet the requirements of NR-101, Part I. r3.3.7 Provisions for Maintainability - Built-in . test equipment, construction and packaging, provisions for test points, and other maintainability parameters shall be in ac
8、cordance with the intent of AR-10. *3.3,8 Nomenclature, Nameplates and Identification varking - Nomenclature and serial number assignment, nameplate approval and identification marking shall be in accordance with Specification MIL-N-18307. 3.3.9 Standard Conditions - The following conditions shall b
9、e used to establish normal performance characteristics under standard conditions and for making laboratory bench tests: Temperature Altitude Vibration Humidity Room ambient (25OC I5“C) Normal Ground None Room ambient up to 90% relative humidity Input power voltage 115 k 1.0 VAC, 3 phase, 400 HZ 3.3.
10、10 Service Conditions - The equipment shall operate satisfactorily under any of the environmental service conditions or reasonable combination of these conditions as specified in Specification MIL-E-5400 for Class 1A equipment as modified herein. 3.3.10.1 Vibration - The equipment shall operate sat-
11、 isfactorily when subjected to the vibration requirements of Curve I of Specification MIL-E-5400 or f2g, whichever is less. *3 -3.10.2 Temperature - The equipiiient shall perform satisfactorily when operated within the temperature range of -25OC to +55“C. Degraded performznce will be permitted withi
12、n, the temperature range of -54OC to -25OC, and +55“C to +7loC. 7 - - - . . - _- -. _- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-C-81343C 58 7Ob OL702O I m MIL-R-81343C (AS) 3.3.11 Warm-Up Tiine - The time required .for equip- ment warm-up
13、 shall be kept to a minimum and shall not exceed 3 minutes under standard conditions, and 5 minutes at -25OC. Turn-on capability shall be maintained down to a temperature of 754C with no damage to the equipment. . 3.3.12 II *3.3.12.1 Operating Power - The equipment shall meet . all applicable requir
14、ements of MIL-STD-704 and shall give . specified performance from the following power source with characteristics as defined in MIL-STD-704 having limits as defined herein. The equipment shall operate within the bounds of limits 2 and 3 of Figure 3 of MIL-STD-704, except that the upper operating lim
15、it shall be 130 volts and the lower operat- ing limit shall be 100 volts. Degraded operation may occur when the input voltage exceeds the above limits but remains within limits 1 and 4 of Figure 3 of MIL-STD-704. However, no damage shall be suffered by the equipment and normal opera tio shall automa
16、tically resume upon return of the input voltage to levels wthin the operating limits as defined above. The power , required shall not exceed the following specified amounts: . AC Power - 115 V, Category “B“, 600 V.A.30 r3.3.12.2 Lighting Power - Input power for lighting shall require not more than 0
17、.5 amp at .28 volts. *3.3.12.3 Degraded Performance - Degraded performance will be permitted for voltage transients not exceeding 0.5 second during normal electric system operation. Operation shall return to normal with no resulting damage to the equipment. 3.4 Performance - Unless otherwise specifi
18、ed, values set forth to establish the requirements for satisfactory performance apply to performance under both standard and extreme service conditions. When reduced pergormance under the extreme conditions is acceptable, tolerances or values setting forth 8 Provided by IHSNot for ResaleNo reproduct
19、ion or networking permitted without license from IHS-,-,-MIL-R-81343C (AS) acceptable variations from the performance under the standard conditions will be specified. *3.4.1 Operation - The Radar Scan Converter Group shall convert, offset, and store the outputs of the AN/APS-115 Radar and IFF unit f
20、or presentation on the Multipurpose Display, in response to digital commands from the Data Processing System. . *3.4,2 Registration - When presented on a Multipur- pose Display, the converted video output and the raw video output of the Radar Scan Converter Group shall register within 1% of the usab
21、le diameter. *3.4.3 Resolution - The Radar Scan Converter Group shall be capable of storing and converting a minimum of 200 discernible range rings. 3.5 Detailed Requirements , *3.5.1 Radar Interface Unit MX-7974/ASA-69 - The Radar Interface Unit (RIU) shall meet the following requirements: *3 . 5.1
22、.1 Function - The RIU shall provide the interface necessary to perform the following functions: a. The Radar Interface Unit shall accept video, trigger, and azimuth information from the AN/APS-115 ,and IFF video from the AN/APX-76, and convert these signals to the necessary horizontal and vertical s
23、weeps, video, and unblank signals required for the writing of the radar presenta- tion on the storage tube of Radar Scan Converter CV-2425/ASA-69 and for the display of Raw Radar Video on the MPD. b. The Radar Interface Unit shall accept data from the Digital Output Multiplexer and the Master Timing
24、 Logic, parts of Data Processing System AN/AYA-8, provide the ground stabilization X and Y offset voltages to the radar sweep origin at the write side of the Scan Converter Unit, and execute the commands associated with radar storage and display ,presentat ion. 9 - . - . . . . .- -I - -* - .,- . . .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC81343C1970CONVERTERGROUPRADARSCANANASA69ANASA69 雷达 扫描 变换器 PDF

链接地址:http://www.mydoc123.com/p-977978.html