NAVISTAR MPAPS F-1-2017 Fluid Connections (Liquid Gas Hose Tube).pdf
《NAVISTAR MPAPS F-1-2017 Fluid Connections (Liquid Gas Hose Tube).pdf》由会员分享,可在线阅读,更多相关《NAVISTAR MPAPS F-1-2017 Fluid Connections (Liquid Gas Hose Tube).pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. NOVEMBER 2017 Page 1 of 21 NAVISTAR, INC. Material, Parts, and Process Specificati
2、ons (MPAPS) NUMBER: MPAPS F-1 Former Designation: CEMS F-1 TITLE: Fluid Connections (Liquid/Gas/Hose/Tube) CURRENT REV No.: 1711 DATE: Nov. 2017 WRITTEN/EDITED BY: N. Krolikiewicz APPROVED BY: R. Goluch SUPERSEDES: Rev. 1510 Oct. 2015 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVI
3、SION This specification may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regula
4、tory limits prior to use. 1.0 APPLICATION This specification covers coolant, oil, and air hose/tube joints with clamps. 2.0 SCOPE This document covers general specifications and dimensions for fluid connectors, hoses, and clamps. It includes all the requirements needed for a reliable and sealed conn
5、ection. 2.1 Restricted Chemical Substances Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the requirements of the MPAPS B-50 specification. 3.0 REFERENCE DOCUMENTS Unless otherwise specified, the latest issue of all referenced standards sha
6、ll apply. The following standards, specifications and regulations are referenced in this specification. Quality System Standard ISO 9001 or TS-16949 NAVISTAR MPAPS F-1058 SAE J1508 NAVISTAR Supplier Packing and Shipping Std. D-13 NAVISTAR MPAPS B-50 SAE J1610 NAVISTAR Engineering Design Std. A-16 NA
7、VISTAR MPAPS F-30 SAE J20 CFR Title 29, Part 1910 NAVISTAR MPAPS F-0 SAE J1684 ASME/ANSI Y 14.5M-1994 (1994 reqd) NAVISTAR MPAPS F-1 APPX SAE J1697 NAVISTAR MPAPS A-9 NAVISTAR MPAPS F-2 SAE J1231 NAVISTAR MPAPS A-37 NAVISTAR MPAPS C-1059 NAVISTAR MPAPS B-1 NAVISTAR MPAPS P-9543 NAVISTAR MPAPS DT-9 N
8、AVISTAR TDS-SD-5.5 NAVISTAR EM-16 ASTM D 380 NUMBER: MPAPS F-1 TITLE: Fluid Connections (Liquid/Gas/Hose/Tube) REVISION: 1711 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume a
9、ll patent liability. 2017 by Navistar, Inc. NOVEMBER 2017 Page 2 of 21 4.0 REQUIREMENTS 4.1 FITTINGS AND END FORMS 4.1.1 Requirements for a Fitting 4.1.1.1 Interference Fit - The difference between the connector OD and hose ID. This difference directly affects hose joint sealing integrity. A non-int
10、erference fit condition may not sustain a permanent seal (0.1 - 1.5 mm interference is required). For 50 mm (2 in) and above, 0.1 - 1.5 mm interference is recommended, but it requires verification for insertion force. Note that Navistar bulk hose with ID less than 12.7mm (0.5 in) does not currently
11、meet the interference specification. 4.1.1.2 Lead In (Dim. A Figure 1) - Surface that provides a ramp and pilot for hose installation. 4.1.1.3 Bead Height (Dim. C Figure 1) - It is used to resist hose and clamp blow-off from the connector (Barb OD recommended is 103.5 - 105% of the connector OD over
12、 2 inches. For connector OD less than 2 inches, refer to Table 1). 4.1.1.4 Hose Stop - A connector feature to allow correct positioning of the hose and clamp onto the connector. It prevents further insertion of the hose and informs the installer that the hose has been properly installed. It can be u
13、sed for radial alignment of the hose. A hose stop feature shall be included on every fitting or tube. 4.1.1.5 Land Length (Dim. E Figure 1) - Is the distance between the bead and connector hose stop. This area is the primary sealing surface for the hose and clamp joint. The land length will vary by
14、the hose size and clamp width. 4.1.1.6 Push on Force - Is the effort required to install the hose over the bead. A lubricant can be used to reduce this. Preferred force is less than 188N (42 lbf). 4.1.1.7 Lubricant - An assembly aid to assist insertion of the hose onto the connector, applied to the
15、hose I.D. This can vary by hose material and system compatibility. A surfactant such as DuPonts MERPOL at 100:1 with water, straight water or dry, is permitted. A rubber assembly lubricant (International Products P80 is allowed, part number 2644105R1) is allowed, see section 4.2.2. Detergent and wat
16、er (100:1 dilution) and other lubricants may be used but shall be evaluated by Materials Engineering for deleterious effects before use. 4.1.1.8 Connector Surface Finish - This is a measurement of surface profile of the connector land area Surface roughness value not to exceed Ra 3.2 m (Ra 125 in) r
17、equired. The land area and bead surface must be free of burrs, seams, flash or any residual grind marks from stock removal. This requirement applies for unpainted and plated/painted surfaces AFTER they are plated or painted. Refer to MPAPS F-1058 and MPAPS C-1059. NUMBER: MPAPS F-1 TITLE: Fluid Conn
18、ections (Liquid/Gas/Hose/Tube) REVISION: 1711 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. NOVEMBER 2017 Page 3 of 21 FIGURE 1:
19、 REFERENCE CONNECTOR SKETCH 4.1.2 Beaded Formed Tube Ends Beaded formed tube ends are suitable for hose connections made with or without hose clamps in relatively low pressure applications. Dimensions shown in Figure 2 and Table 1 shall apply to finished ends, plated, or otherwise processed and appl
20、y to metal tubing having an nominal wall thickness of 0.028 0.083 in (0.71 2.11 mm). Forming of tubes having a wall thickness outside this range may require adjustment of dimensions. Formed tube ends shall be free from burrs, cracks, sharp edges, irregularities in diameters and any other defects aff
21、ecting serviceability. As-cast nipples are prohibited on any connectors and tubes ends. NOTE: TOLERANCE ON ALL DIMENSIONS IN TABLES 1 THROUGH 3 BELOW, NOT OTHERWISE SPECIFIED, SHALL BE 0.01 IN (0.25MM). NUMBER: MPAPS F-1 TITLE: Fluid Connections (Liquid/Gas/Hose/Tube) REVISION: 1711 This document is
22、 restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. NOVEMBER 2017 Page 4 of 21 FIGURE 2: FORMED TUBE DESIGN, MPAPS F-1058 FIG 17, DIMENSIONS ARE IN TA
23、BLE 2 NOTE: Follow Design in Figure 2 and dimensions in Table 1 for Formed Tubes of 1.5in OD and less Nominal Tube OD Tube ID and Wall Thickness (+/-) Taper End Diameter (B) Bead OD (A) Bead to tube end (C) Max Radius (D) Max Radius (E) Total Engagement Length (F) Land clamp area (G) (Reference) Lan
24、d Clamp Area with Prefix (Undesired) in mm Check tube materials from drawing and refer to MPAPS F-1058 for Grade and finish and then MPAPS A-10 for Tube OD and wall thickness tolerance per Grade +0.00 / - 0.03 in +0.00 / - 0.76 mm (+/-) 0.010 in (+/-) 0.25 mm (+/-) 0.04 in (+/-) 1.0 mm in mm in mm (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVISTARMPAPSF12017FLUIDCONNECTIONSLIQUIDGASHOSETUBEPDF

链接地址:http://www.mydoc123.com/p-962937.html