ITU-T O 27-1988 In-Station Echo Canceller Test Equipment《在站回波抵消测试设备-规格为测量设备(第4研究组)共7页》.pdf
《ITU-T O 27-1988 In-Station Echo Canceller Test Equipment《在站回波抵消测试设备-规格为测量设备(第4研究组)共7页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 27-1988 In-Station Echo Canceller Test Equipment《在站回波抵消测试设备-规格为测量设备(第4研究组)共7页》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#)&)#!4)/.3G0G0&/2G0G0-%!352).G0G0%15)0-%.4).G1334!4)/.G0G0%#(/G0G0#!.#%,%2G0G04%34%15)0-%.4)45G134G0G0RecommendationG0G0 (Extract from the “LUEG0“OOK)NOTES1 ITU-T Recommendation O.27 was published in Fasc
2、icle IV.4 of the Blue Book. This file is an extract from theBlue Book. While the presentation and layout of the text might be slightly different from the Blue Book version, thecontents of the file are identical to the Blue Book version and copyright conditions remain unchanged (see below).2 In this
3、Recommendation, the expression “Administration” is used for conciseness to indicate both atelecommunication administration and a recognized operating agency. ITU 1988, 1993All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic ormechani
4、cal, including photocopying and microfilm, without permission in writing from the ITU.Fascicle IV.4 - Rec. O.27 1Recommendation O.27Fascicle IV.4 - Rec. O.27INSTATION ECHO CANCELLER TEST EQUIPMENT(Melbourne, 1988)1 GeneralThe in-station echo canceller test equipment (ISET) is intended to test type C
5、 and D echo cancellers includingtone disablers as specified in Recommendation G.165 1. Two test modes are provided as described below. The testsperformed in each test mode are listed in Table 1/O.27.2 Test modes2.1 Routine test modeIn this test mode, ISET provides 7 simplified tests of echo cancelle
6、r performance under normal circuitconditions with the adaptation and non-linear processing logic activated. Access to the echo canceller being tested is ona 4-wire basis, and these simple performance tests are made by applying test signals to the receive-in (Rin) and thesend-in (Sin) ports of the ec
7、ho canceller. Test results are measured at the send-out (Sout) port. A functional blockdiagram of the test arrangement is shown in Figure 1/O.27.FIGURE 1/O.27Functional block diagram of test arrangement2.2 Diagnostic test modeIn this mode, all performance tests are made according to procedures speci
8、fied in Recommendation G.1651. The adaptation and non-linear processing logic is disabled when necessary by controlling the echo canceller that isbeing tested.2 Fascicle IV.4 - Rec. O.273 Operating principles3.1 Method of accessWhen an echo canceller to be tested is fitted to a particular circuit, a
9、 reserved echo canceller should besubstituted so that the tests can be made without causing any disturbance to the circuit. If no reserved echo canceller isavailable, the circuit should be blocked from service while the tests are being performed.ISET may be connected to an echo canceller under test
10、either manually at local access points or remotely byaccess arrangements through a switching system. Administrations may wish to provide remote access capability to echocancellers for routine tests as shown in Figure 2/O.27. Local access as shown in Figure 3/O.27 is for diagnostic testswhere the use
11、 of control signals to inhibit the H register, adaptation and center clipper logic are needed.FIGURE 2/O.27Configuration for routine test modeAI Adaptation inhibitHC H register clearCO Centre clipper offEC Echo cancellerISET In-station echocanceller testerFIGURE 3/O.27Configuration for diagnostic te
12、st modeFascicle IV.4 - Rec. O.27 33.2 Testing sequencesWhen access has been established, a series of tests is performed manually or automatically. The tests to beperformed in the routine and diagnostic test modes are given in Table 1/O.27. Measurement results for each test shallbe provided to the ma
13、intenance personel by a visual display or printed message.If an echo canceller fails any of the routine tests, it should be completely tested in the diagnostic test mode.TABLE 1/O.27Test ProceduresNo. Type of TestG.165 1Test modesReferenceRoutine Diagnostic1 Steady state residual and returned echo l
14、evel test 3.4.2.1 0 02 Convergence test 3.4.2.2 0 03 Double talk detection oversensitivity test 3.4.2.3.1 0 04 Double talk detection undersensitivity test 3.4.2.3.2 0 05 Leak rate test 3.4.2.4 06 Infinite return loss convergence test 3.4.2.5 0 07 Tone disabler send side sensitivity test 4.2 0 08 Ton
15、e disabler receive side sensitivity test 4.2 0 09 Tone disabler guard band test 4.3 010 Tone disabler holding band test 4.4 011 Tone disabler operate time test 4.5 012 Tone disabler release time test 4.8 013 External disabler control test 3.3 04 Test procedures and test requirements4.1 Routine test
16、modeFigure 1/O.27 shows a functional arrangement for the routine test mode. The following seven tests should berepeated with an appropriate echo path delay ms1set in the adjustable echo delay unit.At the beginning of each of the seven tests, a conditioning tone is applied for 1 second to the Rinport
17、 forinitialization of the echo canceller to be tested. The conditioning tone is a 2100 Hz signal of 10 dBm0 with periodicphase reversals occurring every 0.45 seconds and is also used to disable echo cancellers. During this initializationperiod the H register of the canceller is cleared. After the co
18、nditioning tone is disconnected, no signal is applied to thecanceller for at least 0.4 seconds to allow it to return to an enabled state. Further information on the characteristics ofecho canceller tone disablers may be found in 4 and Annex B of Recommendation G.165 1._1Different echo cancellers may
19、 be designed to work satisfactorily for different echo path delays depending on their application invarious networks. Thus represents the echo path delay for which the echo canceller is designed. Each Administration may choosea delay value of appropriate for their equipment.4 Fascicle IV.4 - Rec. O.
20、274.1.1 Check of steady state residual and returned echo levelStep 1: A random noise signal (A) of 10 dBm0 is applied to the Rinport. With the echo path loss setat 10 dB, an echo appears at the Sinport.Step 2: After 2 seconds the returned echo level at the Soutport is measured.Requirement: The retur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO271988INSTATIONECHOCANCELLERTESTEQUIPMENT 回波 抵消 测试 设备 规格 测量 研究 PDF

链接地址:http://www.mydoc123.com/p-800422.html