ICEA T-30-520-1986 Conducting Vertical Cable Tray Flame Tests with Theoretical Heat Input Rate of 70 000 B T U Hour ( For Reference Only ).pdf
《ICEA T-30-520-1986 Conducting Vertical Cable Tray Flame Tests with Theoretical Heat Input Rate of 70 000 B T U Hour ( For Reference Only ).pdf》由会员分享,可在线阅读,更多相关《ICEA T-30-520-1986 Conducting Vertical Cable Tray Flame Tests with Theoretical Heat Input Rate of 70 000 B T U Hour ( For Reference Only ).pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 ICEA T-30-520 6 9007034 OOOL065 028 M GUIDE FOR CONDUCTING VERTICAL CABLE TRAY FLAME TESTS With Theoretical Heat Input Rate Of 70,000 B.T.U./HOUR PUBLICATION T-30-520 SEPTEMBER 1986 1986 by INSULATED CABLE ENGINEERS ASSOCIATION, INC. - ICEA T-30-520 8b = 9007034 OOOLObb Tb4 W FOREWORD ICEA publicat
2、ions are adopted in the public interest and are designed to eliminate misunderstanding be- tween the manufacturer and user and to assist the user in selecting and obtaining proper products for his particu!ar need. Existence of an ICEA publication does not in any respect preclude the manufadure or us
3、e of products not conforming to the publication. The user of this publication is cautioned to observe any health or safety regulations and rules relative to the manufacture and use of cable covered by this document. Suggestions for improvements in this publication are welcome, and should be sent to
4、ICEA at the address below. Copyrighted by the ICEA Contents may not be reproduced in any form without permission of the INSULATED CABLE ENGINEERS ASSOCIATION, Inc. Copies of this publication may be obtained from: Insulated Cable Engineers Association, Inc. Post Office Box P South Yarmouth, Massachus
5、etts 02664 Telephone: (617) 394-4424 ICEA Pub. T-30-520 VERTICAL TRAY 70,00O*BTU/HR FLAME TEST PROCEDURE FOR CABLES 1.0 SCOPE: 1.1 THIS FLAME TEST SHALL BE CONDUCTED TO DETERMINE RELATIVE RESISTANCE TO FLAME PROPAGATION UNDER SPECIFIED TEST CONDITIONS FOR A GIVEN CABLE CONSTRUCTION. 1.2 THE ABILITY
6、OF A CABLE TO RESIST PROPAGATION TO THE TOP OF THE TRAY DOES NOT GUARANTEE THAT PROPAGATION OF THAT SAME CABLE CANNOT OCCUR UNDER INSTALLED CONDITIONS DURING AN ACTUAL FIRE NOR DOES IT PRECLUDE THE NEED FOR OTHER FIRE SUPPRESSIVE SYSTEMS. 2.0 SUMMARY OF METHOD: 2.1 MULTIPLE LENGTHS OF CABLES ARE ATT
7、ACHED TO A VERTICAL TRAY AND ARE SUBJECTED TO A DEFINED PROPANE GAS FLAME FOR A 20 MINUTE PERIOD. AT THE END OF THE TEST THE AMOUNT OF BURN DAMAGE TO THE CABLES IS DETERMINED. 3.0 FLAME TEST FACILITY: 3.1 TEST SHALL BE CONDUCTED IN A NATURALLY VENTILATED ROOM, OR AN ENCLOSURE, FREE FROM EXCESS DRAFT
8、S AND SPURIOUS AIR CURRENTS. DURING OPERATION THERE SHOULD BE SUFFICIENT VENTILATION SO THAT BURNING IS NOT LIMITED BY A BUILD-UP OF COMBUSTION PRODUCTS OR BY A DEARTH OF MAKE-UP AIR. 4.0 TEST EQUIPMENT: 4.1 THE TEST TRAY SHALL BE A VERTICAL LADDER TYPE STEEL TRAY 12 INCHES WIDE BY 8 FEET LONG. THE
9、SIDE CHANNELS SHALL BE 3 INCHES DEEP WITH 1 INCH FLANGES AND 0.060 INCHES THICK. THE RUNGS SHALL BE 1 X Paqe 1 *THEORETICAL HEAT INPUT ICEA T-30-520 86 m 9007034 000LOb8 837 m T-30-520 Pase 2 4.2 4.3 4.4 4.5 4.6 1/2 INCHES U-SHAPED CHANNELS, 0.125 INCHES THICK AND WELDED TO THE SIDE RAILS AT 9 INCHE
10、S ON CENTER. THE 10-INCH RIBBON GAS BURNER AND AIR GAS VENTURI MIXER SHALL BE BY AMERICAN GAS FURNACE COMPANY, CATALOG NUMBER 1OL-11-55 AND 14-18 RESPECTIVELY, OR EQUIVALENTS. GAS AND AIR FLOW METERS WILL BE USED AND MUST MEET THE SPECIFIED LIMITS DETERMINED BY THE TEST SET-UP. THE GAS SHALL BE NATU
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ICEAT305201986CONDUCTINGVERTICALCABLETRAYFLAMETESTSWITHTHEORETICALHEATINPUTRATEOF70000BTUHOURFORREFERENCEONLYPDF

链接地址:http://www.mydoc123.com/p-783269.html