GMW GMW16708-2012 Overall Seat Hardness and Seat Hardness Distribution Test Procedure Issue 1 English.pdf
《GMW GMW16708-2012 Overall Seat Hardness and Seat Hardness Distribution Test Procedure Issue 1 English.pdf》由会员分享,可在线阅读,更多相关《GMW GMW16708-2012 Overall Seat Hardness and Seat Hardness Distribution Test Procedure Issue 1 English.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW16708 Overall Seat Hardness and Seat Hardness Distribution Test Procedure Copyright 2012 General Motors Company All Rights Reserved June 2012 Originating Department: North American Engineering Standards Page 1 of 20 1 Scope Note: Nothing in this sta
2、ndard supercedes applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. This document provides test methods for evaluating performance characteristics of motor vehicle seating related to occu
3、pant support, penetration, and comfort. It provides a means of comparing and assessing comfort-related performance of complete prototype or competitive benchmark vehicle seat systems. 1.2 Foreword. The tools and procedures for determining seat coordinate positions used in this document are based on
4、the SAE J826 H-Point Machine (Manikin). 1.3 Applicability. These test procedures apply to complete seat systems (production seats or prototypes built at the intended manufacturing quality). Testing must be performed on complete seat backs and complete seat cushions. Tests performed on subsystems or
5、individual components will not be considered valid. For convenience and simplicity, many terms associated with H-Point devices use human body parts in their name. However, they should not be construed as measures that indicate interaction with any or all occupants concerning accommodation, human cap
6、abilities, or comfort. H-Point devices do not represent the size or posture of any category of occupant (see SAE J2896). 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. SAE J826 SAE J2896 2.2 GM Standards/Specifi
7、cations. GMW16710 GMW16719 GMW16712 2.3 Additional References. None 3 Resources 3.1 Facilities. Tests must be performed in a climate controlled area capable of maintaining a constant temperature of 23 C 2 C and a relative humidity of 50% 5%. 3.2 Equipment. 3.2.1 Load/Deflection Measuring System. A s
8、ystem capable of applying forces up to 1500 N at a constant rate and measuring the resulting indenter position is required. Optionally, a system that is capable of performing tests on the seat, while the seat is mounted in the vehicle, may be used, provided the vehicle suspension effects are removed
9、. 3.2.2 Seat Fixture. Fixture capable of simulating the position of the seat within the vehicle and capable of mounting the seat in positions required for testing of seat cushion and seat back. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo
10、 reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW16708 Copyright 2012 General Motors Company All Rights Reserved June 2012 Page 2 of 20 3.2.3 Indenters. For overall seat cushion measurements, the SAE J826 buttock form, as seen in Figure 1, shal
11、l be used with a fixed joint. If overall seat back measurements are desired, the SAE J826 back form shall be used with a fixed joint. Figure 1: SAE J826 Buttock and Back Pans for Overall Cushion/Seat Back Measurements Note: For the Hardness Distribution Test, an indenter, as shown in Figure 2, is to
12、 be used. Figure 2: Indenter for Hardness Distribution Test 3.3 Test Vehicle/Test Piece. A complete seat created at the intended level of manufacturing quality shall be used. 3.4 Test Time. Calendar time: 1.5 days Test hours: 8 hours Coordination hours: 4 hours 3.5 Test Required Information. Torso a
13、ngle, thigh angle, and Seating Reference Point (SgRP). For General Motors vehicles, the seat should be set into the audit position per GMW16710 and the design SgRP used. For Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or net
14、working permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW16708 Copyright 2012 General Motors Company All Rights Reserved June 2012 Page 3 of 20 competitive/Non-GM vehicles, the seat should be placed and the H-Point found using GMW16719. SgRP/ H-Point will be referred to a
15、s the reference point in this procedure. 3.6 Personnel/Skills. Test requires an engineer or technician capable of mounting the seat and running test machinery. 4 Procedure 4.1 Preparation. The specimen should be conditioned, undeflected, and undistorted at 23 C 2 C and relative humidity of 50% 5% fo
16、r at least 4 h before being tested. The tests shall be performed 72 h or more after the manufacturing of the raw materials used in the test specimen (foam, elastic components other than metal, etc.) 4.2 Conditions. 4.2.1 Environmental Conditions. Test shall be run at 23 C 2 C and relative humidity o
17、f 50% 5%. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4.3 Instructions. 4.3.1 Seat Setup. The seats shall be placed into the same position used for f
18、inding H-Point. For General Motors vehicles, GMW16710 shall be used. For competitive/Non-GM vehicles, GMW16719 shall be used. Any nonstandard adjustable features should be set to the specified positions. If no setting is specified, features should be set to full off or retracted position (e.g., lumb
19、ar support or thigh extender). Note: When setting the tilt on the seat, it should be set in the neutral position (middle position); if no tilt position is specified. Measurements shall be referenced to the H-Point, thigh angle, and the torso angle. For General Motors vehicles, the nominal values sha
20、ll be provided by GM. Loading direction is to be normal to thigh angle (cushion) and torso angle (back) as shown in Figures 3 thru 5. If a competitive seat is to be measured, use H-Point procedure from GMW16719 to set the seat in the correct position. For seat force vs. deflection testing of competi
21、tive seats, the load direction should be normal to the measured thigh angle and torso angle as seen in Figures 3 thru 5. Figure 3: Load Directions Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without l
22、icense from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW16708 Copyright 2012 General Motors Company All Rights Reserved June 2012 Page 4 of 20 Figure 4: Seat Cushion Fixed, Indentation Normal to Thigh Line Figure 5: Seat Back Fixed, Indentation Normal to Torso Line Notice the Head Restraint Bars a
23、re Supported Seats should be attached to a rigid fixture capable of securing the test sample in proper position and orientation under test conditions. When performing tests on the seat back, the seat back must be supported or blocked so as to keep the frame from bending due to unintended flex or adj
24、uster movement. One way that this may be accomplished is to place blocks underneath the head restraint bars. Place a piece of muslin cotton cloth over the seat area to be checked during all tests. The muslin cloth should be of sufficient size to prevent the machine from contacting the seat. The musl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW167082012OVERALLSEATHARDNESSANDSEATHARDNESSDISTRIBUTIONTESTPROCEDUREISSUE1ENGLISHPDF

链接地址:http://www.mydoc123.com/p-757842.html