1、 WORLDWIDE ENGINEERING STANDARDS General Specification GMW14718 Heating Unit, Air Conditioning Unit Copyright 2011 General Motors Company All Rights Reserved December 2011 Originating Department: North American Engineering Standards Page 1 of 7 1 Introduction Note: Nothing in this standard supercede
2、s applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Scope. This specification covers the operations and functionality of a heating unit and an air conditioning unit. 1.2 Mission/Theme. Not applic
3、able. 1.3 Classification. Not applicable. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. GMW3052 GMW3059 GMW14780 GMW15922 GMW3055 GMW14482 GMW14782 2.3 Additional Reference
4、s. GM Best Practices for Heater Core Mounting Isolation and Evaporator Mounting Isolation Heating Ventilation Air Conditioning (HVAC) Subsystem Technical Specification (SSTS) 3 Test Preparation and Evaluation 3.1 Resources. 3.1.1 Calibration. The test facilities and equipment shall be in good workin
5、g order and shall have a valid calibration label. 3.1.2 Alternatives. Alternative test facilities and equipment may also be used. However, all measuring variables as specified in this standard shall be determined correctly with respect to their physical definition. 3.1.3 Facilities. Not applicable.
6、3.1.4 Equipment. Not applicable. 3.1.5 Test Vehicle/Test Piece. Not applicable. 3.1.6 Test Time. Not applicable. 3.1.7 Test Required Information. Not applicable. 3.1.8 Personnel/Skills. Not applicable. 3.2 Preparation. Not applicable. 3.3 Conditions. 3.3.1 Environmental Conditions. As defined in Sec
7、tion 4 of this standard. 3.3.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. Test conditions are as defined in Section 4 of this standard. Copyright General
8、Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW14718 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 2 of 7 3.4 Instructions.
9、 As defined in Section 4 of this standard. 3.5 Data. The results recorded during the tests shall be analyzed and included in the test report per the referenced procedure or Subsystem Technical Specification (SSTS). 3.6 Safety. This standard may involve hazardous materials, operations, and equipment.
10、 This standard does not propose to address all the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 3.7 Documentation. Samples of
11、 components or material released to this standard shall be tested for conformity with the requirements of this standard and approved by the responsible GM Department prior to the start of delivery of production level components or materials. Any change to the component or material, e.g., design, fun
12、ction, properties, manufacturing process and/or location of manufacture requires a new release of the product. It is the sole responsibility of the supplier to provide the customer, unsolicited, with documentation of any change or modification to the product/process, and to apply for a new release.
13、If not otherwise agreed to, the entire verification test shall be repeated and documented by the supplier prior to start of delivery of the modified or changed product. In some cases, a shorter test can be agreed to between the responsible GM department and the supplier. 3.7.1 Test Results. As defin
14、ed in Section 4 of this standard. 3.7.2 Deviations from Test Procedure. Deviations from the test procedures shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4 Requirements and Procedure 4.1 General. The heating units and air co
15、nditioning units shall fulfill the requirements according to GMW14780. 4.2 Color. All components visible in the vehicle (passenger compartment) shall be black. 4.3 Fastening of Levers. The levers shall be securely fastened to the valves. The pull-off force shall be 200 N (minimum) and 500 N (maximum
16、) if press forced levers are used. In the case of positive coupled levers, easy assembly and disassembly shall be guaranteed. There is no play permissible between lever and axis. 4.4 Play at Bearings. The movement at the levers shall not exceed 0.5 mm at the point of force application when valves ar
17、e locked (temperature and mode valves). This shall be measured in plane of actuation with an effort of 5 N in both directions. 4.5 Water Drainage, Condensate. It shall be guaranteed that condensate can drain from the climate unit, if the vehicle is tilted 28 cm (11 in) in a longitudinal and/or trans
18、verse direction. Condensate shall not be trapped within the case. 4.6 Water Carryover. No water (drops, fog, steam, or mist) shall escape from the air outlets when the blower is operated at high speed. When the vehicle is tilted 15 in any direction, no condensate shall escape from the air conditioni
19、ng unit. Test according to GMW3055. 4.7 Condensate Build-up. On the outside of components of heating and air conditioning units, no condensate build-up is permitted at (30 1) C and (80 1)% relative humidity. The test is in accordance with GMW3052. 4.8 Functional Test. 4.8.1 Heating Performance and A
20、ir Outlet Temperature. The measurements shall be performed on an assembled Heating unit or HVAC unit under the test conditions in Table 1. The temperature door/valve will be closed by the control head. A closing effort of 5 N (maximum) is to be input at the control head (no permanent load at control
21、 head). Requirements for heater performance or air outlet temperature are in drawings or SSTS documents. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERI
22、NG STANDARDS GMW14718 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 3 of 7 Table 1: Outlet Temperature Test Conditions Airflow: 450 kg/h (90 L/s) at -20 C Heater or Defrost Mode Air Direction: Floor (heater) and defrost Coolant Flow: (0.2 0.01) L/s, (50% water, 50% gly
23、col) Coolant Temperature at Entrance to Heater Core: (+85 1) C Air Inlet Temperature: (-20 1) C Ambient Temperature: (-20 3) C 4.8.2 Temperature Control. Test according to GMW15922. 4.8.3 Heat Pick-up. With the temperature valve in full cold position, the increase of air temperature between the air
24、inlet and air outlet shall meet requirements in all possible modes: HVAC unit: 2 C maximum differential. Heating unit with water shut-off valve: 1 C maximum differential. Test conditions from paragraph 4.8.1 are applied. The temperature valves are to be closed by the control unit. In case of manual
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW147182011HEATINGUNITAIRCONDITIONINGUNITISSUE2ENGLISH 加热 装置 空气调节 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757547.html