FORD WSS-M15P40-B1-2018 PERFORMANCE NETTING ASSEMBLY INTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf
《FORD WSS-M15P40-B1-2018 PERFORMANCE NETTING ASSEMBLY INTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf》由会员分享,可在线阅读,更多相关《FORD WSS-M15P40-B1-2018 PERFORMANCE NETTING ASSEMBLY INTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions Rev. 0 2018 07 27 Released L. Sinclair, NA Controlled document at www.MATS Copyright 2018, Ford Global Technologies, LLC Page 1 of 11 PERFORMANCE, NETTING ASSEMBLY, INTERIOR WSS-M15P40-B1 1. SCOPE The material performance defined by this spec
2、ification is for interior netting assemblies. 2. APPLICATION This specification was released originally for materials used for cargo/convenience nettings including bungee, netting, and webbing. 3. REQUIREMENTS 3.1 APPROVED SOURCES This specification requires the use of approved sources. Only the sou
3、rces identified on the Ford Approved Source List (ASL) can be used when this specification is listed on the drawing, CAD file, or other documents. The list of approved sources is located within Ford at or available externally through a Ford Materials Engineer. 3.2 CONDITIONING AND TEST CONDITIONS A
4、ll test values are based on material conditioned for not less than 24 h prior to testing in a controlled environment of 23 +/- 2 C and 50 +/- 5% relative humidity. Testing shall be conducted within 24 hours of conditioning. 3.3 NETTING PERFORMANCE In addition to the requirements listed herein, the a
5、ssembly shall meet all functional requirements outlined by Engineering, such as IT-0401 (RQT-010500-013161). 3.4 TESTING All evaluations shall be conducted on test specimens taken from production representative netting assemblies. See Table 1 for testing requirements and sample size. Final determina
6、tion of pass/fail criteria for the italicized items will be made by Ford Materials Engineering. 3.5 APPEARANCE The color, pattern, and finish shall match the approved Corporate Design master sample. 3.6 COMPOSITION Report (ASTM D 629) 3.7 PHYSICAL PROPERTIES - NETTING 3.7.1 Breaking Strength Report
7、Average (ASTM D5034, rate of 250 mm/min, Warp and Weft Direction except as below) ENGINEERING MATERIAL SPECIFICATION WSS-M15P40-B1 Copyright 2018, Ford Global Technologies, LLC Page 2 of 11 Use two “J” hooks, each 75 mm long made from Number 8 gauge (4.2 mm) diameter hard drawn spring steel wire or
8、equivalent mounted in steel mandrills (See Figure 1 for J hook orientation). The “J” hooks shall be free of nicks or burrs to prevent damage to the yarn. The breaking of any netting leg shall not result in unravelling beyond the crossover. 3.7.1.1 Retained Breaking Strength 80% of Original min (FLTM
9、 BO 116-01, exposure based on Warp and Weft Direction Criteria below, then test per 3.7.1) In Vehicle Sunlight Exposure Level Test Exposure Severe Exposure: Instrument panel topper 3609.6 kJ/m2 Heavy Exposure: Instrument panel lower top cover 2406.4 kJ/m2 Medium Exposure: Instrument panel lower 977.
10、6 kJ/m2 Mild Exposure: Lower seats, seat backs, cargo opening convenience net, floor console, 601.6 kJ/m2 Low Exposure: Luggage compartment, lower trim 225.6 kJ/m2 3.8 PHYSICAL PROPERTIES - WEBBING 3.8.1 Breaking Strength Report Average Warp Direction (ASTM D5034, 76 mm jaw separation, rate of 250 m
11、m/min Except use Fixture shown in Figures 2-4 in the Appendix) 3.8.1.1 Retained Breaking Strength 80% of Original min (FLTM BO 116-01, exposure based on Warp Direction Criteria below, then test per 3.8.1) In Vehicle Sunlight Exposure Level Test Exposure Severe Exposure: Instrument panel topper 3609.
12、6 kJ/m2 Heavy Exposure: Instrument panel lower top cover 2406.4 kJ/m2 Medium Exposure: Instrument panel lower 977.6 kJ/m2 Mild Exposure: Lower seats, seat backs, cargo opening convenience net, floor console, 601.6 kJ/m2 Low Exposure: Luggage compartment, lower trim 225.6 kJ/m2 3.9 PHYSICAL PROPERTIE
13、S - BUNGEE 3.9.1 Breaking Strength Report Average (ASTM D5034, 76 mm jaw separation, rate of 550 mm/min, fixtures Figure 5-6 in the Appendix) ENGINEERING MATERIAL SPECIFICATION WSS-M15P40-B1 Copyright 2018, Ford Global Technologies, LLC Page 3 of 11 3.9.1.1 Retained Breaking Strength 80% of Original
14、 min (FLTM BO 116-01, exposure based on Criteria below, then test per 3.9.1) In Vehicle Sunlight Exposure Level Test Exposure Severe Exposure: Instrument panel topper 3609.6 kJ/m2 Heavy Exposure: Instrument panel lower top cover 2406.4 kJ/m2 Medium Exposure: Instrument panel lower 977.6 kJ/m2 Mild E
15、xposure: Lower seats, seat backs, cargo opening convenience net, floor console, 601.6 kJ/m2 Low Exposure: Luggage compartment, lower trim 225.6 kJ/m2 3.9.2 Bungee Elongation Report (%) (ASTM D5034, 76 mm jaw separation, rate of 550 mm/min, fixture in Figure 5-6 in the Appendix) Elongate bungee sampl
16、e until force of 35N is reached. Elongation is determined using the following equation: % Elongation = (Length (mm) at 35N) 76 mm x 100 76 mm 3.9.2.1 Retained Elongation 80% of Original min (FLTM BO 116-01, exposure based on Criteria below, then test per 3.9.2) In Vehicle Sunlight Exposure Level Tes
17、t Exposure Severe Exposure: Instrument panel topper 3609.6 kJ/m2 Heavy Exposure: Instrument panel lower top cover 2406.4 kJ/m2 Medium Exposure: Instrument panel lower 977.6 kJ/m2 Mild Exposure: Lower seats, seat backs, cargo opening convenience net, floor console, 601.6 kJ/m2 Low Exposure: Luggage c
18、ompartment, lower trim 225.6 kJ/m2 3.10 COLOR PROPERTIES 3.10.1 Resistance to Crocking (FLTM BN 107-01, AATCC Evaluation Procedure 2) Dry Rating 4 min Wet Rating 4 min ENGINEERING MATERIAL SPECIFICATION WSS-M15P40-B1 Copyright 2018, Ford Global Technologies, LLC Page 4 of 11 3.10.2 Resistance to Int
19、erior Weathering Rating 4 min (FLTM BO 116-01, AATCC Evaluation Procedure 1) In Vehicle Sunlight Exposure Level Test Exposure Severe Exposure: Instrument panel topper 3609.6 kJ/m2 Heavy Exposure: Instrument panel lower top cover 2406.4 kJ/m2 Medium Exposure: Instrument panel lower 977.6 kJ/m2 Mild E
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSSM15P40B12018PERFORMANCENETTINGASSEMBLYINTERIORTOBEUSEDWITHFORDWSSM99P1111APDF

链接地址:http://www.mydoc123.com/p-751310.html