FORD FLTM BV 159-2-2001 FLAMMABILITY OF SEALERS BY WELDING (Replaces FLTM EU-BV 059-02).pdf
《FORD FLTM BV 159-2-2001 FLAMMABILITY OF SEALERS BY WELDING (Replaces FLTM EU-BV 059-02).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BV 159-2-2001 FLAMMABILITY OF SEALERS BY WELDING (Replaces FLTM EU-BV 059-02).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BV 159-02 Date Action Revisions 2001 04 30 Revised Editorial no technical change A. Cockman 1990 05 25 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. FLAMMABILITY OF SEALERS BY WELDING Application These methods are used to dete
2、rmine the flammability of sealers by welding. Method A - Applied as a spot weld sealer material. Method B - Applied as a sealer material over spot weld seams. Apparatus Required Spot Welding Equipment Stationary, 80 KVA with ignition control arrangement or equivalent. Adjust the controls of the spot
3、 welding equipment to give the following conditions: Secondary current 9,000 amps Squeeze time 12 cycles Weld time 8 cycles Hold time 20 cycles minimum Cold time 12 cycles Welding rate 20 welds per minute Electrode pressure 2.3 kN Diameter of weld nugget 6 mm Materials Required Test Panel Steel body
4、 skin panels free from burrs or ragged edges, prepared in accordance with FLTM BZ 150-11 (Normal Grade). Dimensions: 700 x 50 x 0.85 +/- 0.03 mm Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 %
5、 relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BV 159-02 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. Procedure Method A - Applied as a spot weld sealer material. 1. The closed cont
6、ainer of sealant shall be conditioned for 24 h minimum at 23 +/- 2 C prior to application. 2. Apply a bead of the sealer to each of three test panels. The bead shall be 6 mm in diameter and 10 mm from the edge of the panel (see Figure 1, Section AA). 3. Immediately after application of the sealer, p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV15922001FLAMMABILITYOFSEALERSBYWELDINGREPLACESFLTMEUBV05902PDF

链接地址:http://www.mydoc123.com/p-747681.html