FORD FLTM BV 003-04-2000 VIBRATION DAMPENING TEST《振动衰减试验》.pdf
《FORD FLTM BV 003-04-2000 VIBRATION DAMPENING TEST《振动衰减试验》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BV 003-04-2000 VIBRATION DAMPENING TEST《振动衰减试验》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BV 003-04 Date Action Revisions 2000 12 01 Revised Editorial no technical change A. Cockman 1992 08 11 Printed copies are uncontrolled Page 1 of 11 Copyright 2000, Ford Global Technologies, Inc. VIBRATION DAMPENING TEST Application The Vibration Dampening Test rates the
2、dampening efficiency of various types of floor pan mastics, spray-on sound deadeners, combination materials used as instrument panel insulators and carpeting. Apparatus Required Audio Oscillator and Amplifier (Exciter Unit) Drawing ZX-824-9 or equivalent An R.C. type audio oscillator utilizing a 6SJ
3、7 and a 6F6 type tube is the oscillator circuit. One section of a dual triode tube, 6SN7GT, is used as a driver for two 6L6 tubes connected in parallel and the other section of the 6SN7GT is used as a cathode follower (a source of low impedance output which can be used in calibrating the timing desc
4、ribed later). The oscillator has a frequency range of 2 to 20,000 c.p.s. The plate load for the 6L6 tubes is the magnetic driver unit. It consists of a Thordarson type T-13C30 choke which has been modified by rotating the laminations so the core is open. When the unit is mounted close to the steel p
5、late, the steel plate completes the magnetic circuit and when energy is applied to the driver from the exciter unit, the plate will vibrate. Sound Decay Timer - Drawing ZX-879-2 or equivalent The sound decay unit consists of two amplifiers on a common chassis. One amplifier is the start amplifier an
6、d the second is the stop amplifier. The start amplifier utilizes two 6SJ7 tubes, both connected as triodes, one 6H6 dual diode as a full wave signal rectifier and a Type 2050 Thyratron which acts as an electronic switch for the clock. The signal is amplified by the two 6SJ7 tubes and then rectified
7、by the 6H6 and the rectified negative bias is applied to the grid of the 2050 tube. When the input signal decreases to a point where the negative bias on the 2050 tube falls to the “firing“ point, the tube will ignite and the clock will start. The input signal level at which the “firing“ occurs depe
8、nds upon the settings of the start attenuators. The START amplifier will “kick in“ at approximately 2 volts, as indicated by the meter. In order that a correct timing is obtained, it is necessary that the meter reads more than 2 volts before timing is started. A toggle switch located in the rear of
9、the Sound Decay Timer will connect the voltmeter in the STOP thyratron circuit, thereby measuring the negative bias on the tube. The STOP thyratron will “fire“ at about 2 volts also. Magnetic Driver The driver mounted under the center of a test panel excites the steel plate by a varying magnetic fie
10、ld. FORD LABORATORY TEST METHOD BV 003-04 Page 2 of 11 Copyright 2000, Ford Global Technologies, Inc. Permanent Magnet Loudspeaker This is used as a microphone. High Speed Clock Standard Electric Time Co. Type S-1 or equivalent. Regulated Power Supply To be used with clock as required. Vacuum Tube V
11、oltmeter Ballantine Model 300 or equivalent. Steel Panels 20 x 20 x 1/4 inch steel. Panels cut, not sheared, from the center of large sheets of cold rolled low carbon steel. Uniform thickness of the steel panel is required. Center cuts of sheet required to minimize the internal stresses found in out
12、er edges. The edges of the panel must be carefully ground to obtain the desired resonant frequency. Stop Amplifier The second amplifier is the stop amplifier. It consists of a 6SJ7 (triode connected as the input tube), a 6SJ7 (pentode connected) and a 6SN7GT, dual triode (connected as a two-stage am
13、plifier). The remainder is assembled the same as the start amplifier with the exception of the relay coil in the 2050 plate circuit. When this tube “fires“, the circuit is broken to the clock motor and the clock stops. One peculiarity should be noted in the circuitry of the stop amplifier circuit; t
14、hat is, the triode connected 6SJ7 followed by a 6SJ7 connected as a pentode. If the first 6SJ7 were connected as a pentode, the input circuit would be overloaded with a high starting signal and would be in error in timing. With the modified wiring, the maximum starting voltage at the input grid is a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV003042000VIBRATIONDAMPENINGTEST 振动 衰减 试验 PDF

链接地址:http://www.mydoc123.com/p-747573.html