BS EN 61207-2-1994 Expression of performance of gas analyzers - Oxygen in gas (utilizing high-temperature electrochemical sensors)《气体分析器性能说明 第2部分 气体中的氧(利用高温电化检测器)》.pdf
《BS EN 61207-2-1994 Expression of performance of gas analyzers - Oxygen in gas (utilizing high-temperature electrochemical sensors)《气体分析器性能说明 第2部分 气体中的氧(利用高温电化检测器)》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61207-2-1994 Expression of performance of gas analyzers - Oxygen in gas (utilizing high-temperature electrochemical sensors)《气体分析器性能说明 第2部分 气体中的氧(利用高温电化检测器)》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61207-2:1994 IEC 1207-2: 1994 Expression of performance of gas analyzers Part 2: Oxygen in gas (utilizing high-temperature electrochemical sensors) The European Standard EN 61207-2:1994 has the status of a British Standard UDC 621.317.79:543.27:543.25BSEN 61207-2:1994 This Bri
2、tish Standard, having been prepared under the directionof the Electrotechnical Sector Board, was published underthe authority of the Standards Board and comes intoeffect on 15November 1994 BSI 11-1999 The following BSI references relate to the work on this standard: Committee reference PCL/- Draft f
3、or comment 85/21733 DC ISBN 0 580 23514 9 Cooperating organizations The European Committee for Electrotechnical Standardization (CENELEC), under whose supervision this European Standard was prepared, comprises the national committees of the following countries: Austria Italy Belgium Luxembourg Denma
4、rk Netherlands Finland Norway France Portugal Germany Spain Greece Sweden Iceland Switzerland Ireland United Kingdom Amendments issued since publication Amd. No. Date CommentsBSEN 61207-2:1994 BSI 11-1999 i Contents Page Cooperating organizations Inside front cover National foreword ii Foreword 2 Te
5、xt of EN 61207-2 3 National annex NA (informative) Committees responsible Inside back cover National annex NB (informative) Cross-references Inside back coverBSEN 61207-2:1994 ii BSI 11-1999 National foreword This British Standard has been prepared under the direction of the Electrotechnical Sector
6、Board and is the English language version of EN 61207-2:1994 Expression of performance of gas analyzers. Part 2: Oxygen in gas (utilizing high-temperature electrotechnical sensors), published by the European Committee for Electrotechnical Standardization (CENELEC). It is identical with IEC 1207-2:19
7、94 including Corrigendum, May 1994, published by the International Electrotechnical Commission (IEC). IEC 1207-2 constitutes Part 2 of the IEC 1207 series of publications under the general title: Expression of performance of gas analyzers. Other Parts are as follows: Part 1: General; Part 2: Oxygen
8、in gas (utilizing high-temperature electrotechnical sensors); Part 6: Photometric analyzers; Part 7: Infra-red analyzers. Parts 3, 4 and 5 are under consideration. The following print types are used in this standard: requirements proper: in roman type; notes: in smaller roman type. A British Standar
9、d does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an
10、 inside front cover, pages i and ii, theEN title page, pages2 to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.EUROPEAN STANDARD NORME EU
11、ROPENNE EUROPISCHE NORM EN 61207-2 June 1994 UDC 621.317.79:543.27:543.25 Descriptors: Gaseous mixtures, oxygen in gaseous mixtures, gas analyzers, performance of gas analyzers, high temperature electrochemical sensors English version Expression of performance of gas analyzers Part 2: Oxygen in gas
12、(utilizing high-temperature electrochemical sensors) (IEC 1207-2:1994 + corrigendum 1994) Expression des qualits de fonctionnement des analyseurs de gaz Partie 2: Oxygne contenu dans le gaz (utilisant des capteurs lectrochimiques haute temprature) (CEI 1207-2:1994) Angabe zum Betriebsverhalten von G
13、asanalysatoren Teil 2: Sauerstoff in Gas (unter Verwendung von elektrochemischen Hochtemperatur-Sensoren) (IEC 1207-2:1994) This European Standard was approved by CENELEC on 1994-05-15. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for g
14、iving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three officia
15、l versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committ
16、ees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europ
17、isches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1994 Copyright reserved to CENELEC members Ref. No. EN 61207-2:1994 EEN 61207-2:1994 2 BSI 11-1999 Foreword The text of document 65D(CO)3, as prepared by Subcommittee 65D: Analyzing equipment, of IEC
18、 Technical Committee 65: Industrial-process measurement and control, was submitted to the IEC-CENELEC parallel vote in October 1993. The reference document was approved by CENELEC as EN 61207-2 on 15 May 1994. The following dates were fixed: For products which have complied with the relevant nationa
19、l standard before 1995-05-15, as shown by the manufacturer or by a certification body, this previous standard may continue to apply for production until 2000-05-15. Annexes designated “normative” are part of the body of the standard. Annexes designated “informative” are given only for information. I
20、n this standard, Annex ZA is normative. Contents Page Foreword 2 Introduction 3 1 Scope 3 2 Normative references 3 3 Definitions 3 4 Procedures for specification 5 4.1 Specification of essential units and ancillary services 5 4.2 Additional terms related to the specification ofperformance 5 4.3 Impo
21、rtant terms related to the specification ofperformance 5 5 Procedures for compliance testing 6 5.1 General 6 5.2 Testing procedures 6 5.3 Output fluctuation 6 5.4 Delay time, rise time and fall time 6 Annex ZA (normative) Other international publications quoted in this standard with thereferences of
22、 the relevant European publications 10 Figure 1 General test arrangement, in situ analyser 8 Figure 2 General test arrangement, extractiveanalyzer 9 latest date of publication ofan identical national standard (dop) 1995-05-15 latest date of withdrawal ofconflicting national standards (dow) 1995-05-1
23、5EN 61207-2:1994 BSI 11-1999 3 Introduction This part of IEC 1207 includes the terminology, definitions, statements and tests that are specific to oxygen analyzers, which utilise high-temperature electrochemical sensors. Oxygen analyzers employing high-temperature electrochemical sensors operating a
24、t temperatures usually in excess of 600 C, have a wide range of applications for the measurement of oxygen in gas samples. Such samples are typically the result of a combustion process. Two main types of analyzer exist, the in situ analyzer, where the sensor is positioned within the process duct wor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6120721994EXPRESSIONOFPERFORMANCEOFGASANALYZERSOXYGENINGASUTILIZINGHIGHTEMPERATUREELECTROCHEMICALSENSORS

链接地址:http://www.mydoc123.com/p-577098.html